Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

被引:22
|
作者
Leenen, Jobbe P. L. [1 ,2 ]
Dijkman, Eline M. [1 ]
van Dijk, Joris D. [3 ]
van Westreenen, Henderik L. [1 ]
Kalkman, Cor [4 ]
Schoonhoven, Lisette [5 ,6 ]
Patijn, Gijsbert A. [1 ]
机构
[1] Dept Surg, Isala, Zwolle, Netherlands
[2] Connected Care Ctr, Isala, Zwolle, Netherlands
[3] Isala Acad, Isala, Zwolle, Netherlands
[4] UMC Utrecht, Anesthesiol, Utrecht, Netherlands
[5] UMC Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[6] Univ Southampton, Fac Hlth Sci, Southampton, Hants, England
来源
BMJ OPEN | 2021年 / 11卷 / 02期
关键词
surgery; health & safety; adverse events; pancreatic surgery; hepatobiliary surgery; colorectal surgery; EARLY WARNING SCORES; MORTALITY; COMPLICATIONS; IMPACT; CLASSIFICATION; SAFETY; SYSTEM;
D O I
10.1136/bmjopen-2020-042735
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. Design Observational cohort study. Setting Tertiary teaching hospital. Participants Postoperative abdominal surgical patients (n=30) and nurses (n=23). Interventions Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. Outcomes System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. Results Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. Conclusions Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Continuous recording of vital signs with a wearable device in pediatric patients undergoing chemotherapy for cancer—an operational feasibility study
    Christa Koenig
    Roland A. Ammann
    Claudia E. Kuehni
    Jochen Roessler
    Eva Brack
    Supportive Care in Cancer, 2021, 29 : 5283 - 5292
  • [32] Vital Signs Monitoring with Wearable Sensors in High-risk Surgical Patients A Clinical Validation Study
    Breteler, Martine J. M.
    KleinJan, Eline J.
    Dohmen, Daan A. J.
    Leenen, Luke P. H.
    van Hillegersberg, Richard
    Ruurda, Jelle P.
    van Loon, Kim
    Blokhuis, Taco J.
    Kalkman, Cor J.
    ANESTHESIOLOGY, 2020, 132 (03) : 424 - 439
  • [33] Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study
    Knut Øymar
    Kjersti Bårdsen
    BMC Pediatrics, 14
  • [34] Observations and vital signs: ritual or vital for the monitoring of postoperative patients?
    Zeitz, Kathryn
    McCutcheon, Helen
    APPLIED NURSING RESEARCH, 2006, 19 (04) : 204 - 211
  • [35] Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study
    Oymar, Knut
    Bardsen, Kjersti
    BMC PEDIATRICS, 2014, 14
  • [36] Postoperative use of fitness trackers for continuous monitoring of vital signs: a survey of hospitalized patients
    Helmer, Philipp
    Hottenrott, Sebastian
    Wienboeker, Kathrin
    Brugger, Juergen
    Stoppe, Christian
    Schmid, Benedikt
    Kranke, Peter
    Meybohm, Patrick
    Sammeth, Michael
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [37] Changes in vital signs and influencing factors associated with nursing interventions in mechanically ventilated patients: A prospective cohort observational study
    Yomogida, Jun
    Yoshida, Naoto
    INTENSIVE AND CRITICAL CARE NURSING, 2024, 84
  • [38] Design and Development of a Wristband for Continuous Vital Signs Monitoring of COVID-19 Patients
    Nabavi, Seyedfakhreddin
    Bhadra, Sharmistha
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6845 - 6850
  • [39] Continuous recording of vital signs with a wearable device in pediatric patients undergoing chemotherapy for cancer-an operational feasibility study
    Koenig, Christa
    Ammann, Roland A.
    Kuehni, Claudia E.
    Roessler, Jochen
    Brack, Eva
    SUPPORTIVE CARE IN CANCER, 2021, 29 (09) : 5283 - 5292
  • [40] Vital signs monitoring on general wards: clinical staff perceptions of current practices and the planned introduction of continuous monitoring technology
    Prgomet, Mirela
    Cardona-Morrell, Magnolia
    Nicholson, Margaret
    Lake, Rebecca
    Long, Janet
    Westbrook, Johanna
    Braithwaite, Jeffrey
    Hillman, Ken
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2016, 28 (04) : 515 - 521