A comparison of two different bronchial cuff designs and four different bronchial cuff inflation methods

被引:11
|
作者
Guyton, DC [1 ]
Besselievre, TR [1 ]
Devidas, M [1 ]
DeLima, LGR [1 ]
Eichhorn, JH [1 ]
机构
[1] UNIV MISSISSIPPI,MED CTR,DEPT PREVENT MED,JACKSON,MS 39216
关键词
bronchi; equipment design; intratracheal intubation (instrumentation; methods); structural models; artificial respiration (instrumentation;
D O I
10.1016/S1053-0770(97)90012-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare directly measured pressures at the cuff/trachea interface that are associated with two different bronchial cuff designs and four different methods of bronchial cuff inflation suggested for use with one-lung ventilation. Design: In vitro study. Setting: Experimental laboratory in a university-affiliate hospital. Interventions: The bronchial cuffs of two different endotracheal tubes were inflated using one of four different methods of determining the cuff volume and pressure necessary to ''just seal'' the bronchus and obtain lung separation: positive-pressure test, negative-pressure test, CO2 analysis, and a new test using an anesthesia ventilator, When each method predicted the ''just-seal'' state, the pressure at the cuff/bronchus interface as well as cuff inflation pressure and volume were recorded. Measurements and Main Results: Although the new test was incompatible with the bronchial blocker; the other three tests all accurately predicted lung separation with the Univent, with no significant differences in pressures exerted on the trachea. However, when used with the double-lumen tube, the new test produced significantly lower measured parameters than the other inflation methods. CO2 analysis did not reliably predict bronchial seal with the double-lumen tube. Conclusions: To achieve lung separation with the lowest pressure on the trachea, the new test is the most appropriate method for use with the double-lumen tube; however, the negative-pressure test appeared to be the easiest and fastest method for use with the bronchial blocker. Although the bronchial blocker was associated with lower pressures transmitted from the cuff to the trachea, the in vitro model cannot predict which bronchial cuff design would be superior in vivo. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:599 / 603
页数:5
相关论文
共 50 条
  • [21] Comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus.
    Hannallah, MS
    Gharagozloo, F
    Gomes, MN
    Chase, GA
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [22] COMPARISON OF 3 TECHNIQUES TO INFLATE THE BRONCHIAL CUFF OF LEFT POLYVINYLCHLORIDE DOUBLE-LUMEN TUBES
    HANNALLAH, MS
    BENUMOF, JL
    MCCARTHY, PO
    MING, LA
    ANESTHESIA AND ANALGESIA, 1993, 77 (05): : 990 - 994
  • [23] Managing endotracheal tube cuff pressure at altitude: A comparison of four methods
    Britton, Tyler
    Blakeman, Thomas C.
    Eggert, John
    Rodriquez, Dario
    Ortiz, Heather
    Branson, Richard D.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 77 : S240 - S244
  • [24] Bronchial Hyperresponsiveness in sportschildren; Different methods to reach a diagnosis
    Arochena, L.
    Fernandez-Nieto, M.
    Andregnette, V.
    Garcia del Potro, M.
    Aguado, E.
    Sastre, J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2012, 129 (02) : AB2 - AB2
  • [25] Comparison Of Two Different Methods Of Processing Bronchial Brushings On Rna Yield For Transcriptomic Studies In U-Biopred
    Gibeon, D.
    Marriage, F.
    Corfield, J.
    Sousa, A.
    Sogbesan, A.
    Sterk, P. J.
    Howarth, P. H.
    Djukanovic, R.
    Chung, K. F.
    Adcock, I. M.
    Baribaud, F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [26] Comparison of 2 cuff inflation methods before insertion of laryngeal mask airway for safe use without cuff manometer in children
    Kim, Min-Soo
    Bai, Sun-Joon
    Oh, Jung-Tak
    Youm, Seung-Mok
    Lee, Jeong-Rim
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (02): : 346 - 352
  • [27] Comparison of different suture techniques for laparoscopic vaginal cuff closure
    Forster, Christiane E.
    Calabretti, Iliana
    Gubser, Laura
    Schotzau, Andreas
    Fellmann-Fischer, Bernhard
    Heinzelmann-Schwarz, Viola
    Zwimpfer, Tibor A.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [28] Comparison of different suture techniques for laparoscopic vaginal cuff closure
    Christiane E. Förster
    Iliana Calabretti
    Laura Gubser
    Andreas Schötzau
    Bernhard Fellmann-Fischer
    Viola Heinzelmann-Schwarz
    Tibor A. Zwimpfer
    Scientific Reports, 14
  • [29] A COMPARISON OF DIFFERENT PROVOCATION DOSES IN HISTAMINE BRONCHIAL CHALLENGES
    POPA, V
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A373 - A373
  • [30] Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair
    Zhang, Qing-Song
    Liu, Sen
    Zhang, Qiuyang
    Xue, Yun
    Ge, Dongxia
    O'Brien, Michael J.
    Savoie, Felix H.
    You, Zongbing
    ADVANCES IN ORTHOPEDICS, 2012, 2012