Comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus.

被引:0
|
作者
Hannallah, MS
Gharagozloo, F
Gomes, MN
Chase, GA
机构
[1] Georgetown Univ, Med Ctr, Dept Anesthesia, Washington, DC 20007 USA
[2] Georgetown Univ, Med Ctr, Dept Surg, Washington, DC 20007 USA
[3] Georgetown Univ, Med Ctr, Dept Biostat, Washington, DC 20007 USA
来源
ANESTHESIA AND ANALGESIA | 1998年 / 86卷 / 2S期
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
S541
引用
收藏
页数:1
相关论文
共 17 条
  • [1] A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus
    Hannallah, MS
    Gharagozloo, F
    Gomes, MN
    Chase, GA
    ANESTHESIA AND ANALGESIA, 1998, 87 (05): : 1027 - 1031
  • [2] Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: Decreased bronchial tube angulation is a cause?
    Kumar, Amarjeet
    Sinha, Chandni
    Kumari, Poonam
    Nupoor, Neha
    Kumar, Sanjeev
    SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (03) : 262 - +
  • [3] COMPARISON OF 3 TECHNIQUES TO INFLATE THE BRONCHIAL CUFF OF LEFT POLYVINYLCHLORIDE DOUBLE-LUMEN TUBES
    HANNALLAH, MS
    BENUMOF, JL
    MCCARTHY, PO
    MING, LA
    ANESTHESIA AND ANALGESIA, 1993, 77 (05): : 990 - 994
  • [4] COMPARISON OF 3 TECHNIQUES TO INFLATE THE BRONCHIAL CUFF OF LEFT POLYVINYLCHLORIDE (PVC) DOUBLE-LUMEN TUBES (DLT)
    HANNALLAH, M
    BENUMOF, J
    MCCARTHY, P
    LIANG, M
    ANESTHESIOLOGY, 1993, 79 (3A) : A1227 - A1227
  • [5] The margin of safety of a left double-lumen tracheobronchial tube depends on the length of the bronchial cuff and tip
    Partridge, L.
    Russell, W. J.
    ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (05) : 618 - 620
  • [6] Mainstem bronchial diameterfor the left-sided Broncho-Cath® double-lumen tube:: an in vitro study
    Bahk, JH
    Ryu, HG
    Park, JH
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (03): : 341 - 342
  • [7] A CLINICAL COMPARISON OF BRONCHIAL CUFF PRESSURES IN 3 DIFFERENT DESIGNS OF LEFT DOUBLE-LUMEN TUBES
    SLINGER, PD
    CHRIPKO, D
    ANESTHESIA AND ANALGESIA, 1993, 77 (02): : 305 - 308
  • [8] Bronchial cuff pressure change caused by left-sided double-lumen endobronchial tube displacement
    Kazukuni Araki
    Ryoichi Nomura
    Reiko Urushibara
    Yukiko Yoshikawa
    Yoshio Hatano
    Canadian Journal of Anesthesia, 2000, 47 : 775 - 779
  • [9] Bronchial cuff pressure change caused by left-sided double-lumen endobronchial tube displacement
    Araki, K
    Nomura, R
    Urushibara, R
    Yoshikawa, Y
    Hatano, Y
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (08): : 775 - 779
  • [10] Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    Hannallah, M
    Benumof, JL
    Silverman, PM
    Kelly, LC
    Lea, D
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (02) : 168 - 171