A comparison of two different bronchial cuff designs and four different bronchial cuff inflation methods

被引:11
|
作者
Guyton, DC [1 ]
Besselievre, TR [1 ]
Devidas, M [1 ]
DeLima, LGR [1 ]
Eichhorn, JH [1 ]
机构
[1] UNIV MISSISSIPPI,MED CTR,DEPT PREVENT MED,JACKSON,MS 39216
关键词
bronchi; equipment design; intratracheal intubation (instrumentation; methods); structural models; artificial respiration (instrumentation;
D O I
10.1016/S1053-0770(97)90012-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare directly measured pressures at the cuff/trachea interface that are associated with two different bronchial cuff designs and four different methods of bronchial cuff inflation suggested for use with one-lung ventilation. Design: In vitro study. Setting: Experimental laboratory in a university-affiliate hospital. Interventions: The bronchial cuffs of two different endotracheal tubes were inflated using one of four different methods of determining the cuff volume and pressure necessary to ''just seal'' the bronchus and obtain lung separation: positive-pressure test, negative-pressure test, CO2 analysis, and a new test using an anesthesia ventilator, When each method predicted the ''just-seal'' state, the pressure at the cuff/bronchus interface as well as cuff inflation pressure and volume were recorded. Measurements and Main Results: Although the new test was incompatible with the bronchial blocker; the other three tests all accurately predicted lung separation with the Univent, with no significant differences in pressures exerted on the trachea. However, when used with the double-lumen tube, the new test produced significantly lower measured parameters than the other inflation methods. CO2 analysis did not reliably predict bronchial seal with the double-lumen tube. Conclusions: To achieve lung separation with the lowest pressure on the trachea, the new test is the most appropriate method for use with the double-lumen tube; however, the negative-pressure test appeared to be the easiest and fastest method for use with the bronchial blocker. Although the bronchial blocker was associated with lower pressures transmitted from the cuff to the trachea, the in vitro model cannot predict which bronchial cuff design would be superior in vivo. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:599 / 603
页数:5
相关论文
共 50 条
  • [41] BRONCHIAL CHALLENGES WITH DIFFERENT NEBULIZERS
    SCHNEIDER, WD
    MAINTZ, G
    HORST, A
    REBOHLE, E
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1984, 39 (28): : 1095 - 1098
  • [42] Comparison of two methods for computing abduction moment arms of the rotator cuff
    Hughes, RE
    Niebur, G
    Liu, J
    An, KN
    JOURNAL OF BIOMECHANICS, 1998, 31 (02) : 157 - 160
  • [43] Comparison of cuff inflation and cuff deflation brachial sphygmomanometry with intra-arterial blood pressure as reference
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Argha, Ahmadreza
    Rehan, Rajan
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2024, 42 (06) : 968 - 976
  • [44] ASPIRATION OF FLUID ABOVE THE ENDOTRACHEAL TUBE CUFF: A COMPARISON OF TWO METHODS
    Gomaa, Dina
    Roberts, Karsten
    Branson, Richard
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [45] Inflation of the distal cuff by saline reduces the incidence of malposition of the bronchial tube during lung separation in patients receiving nitrous oxide
    Suzuki, Manzo
    Haraguchi, Shuji
    Kitarnura, Akira
    Shimada, Yoichi
    Sakamoto, Atsuhiro
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (06) : 838 - 842
  • [46] Comparison of different bronchial closure techniques following pneumonectomy in dogs
    Salci, Halkan
    Bayram, A. Sarni
    Ozyigit, Ozgur
    Gebitekin, Cengiz
    Gorgul, O. Sacit
    JOURNAL OF VETERINARY SCIENCE, 2007, 8 (04) : 393 - 399
  • [47] Variations in Bronchial Cuff Design of Double Lumen Tube - Does it Impact the Seal?
    Rudingwa, Priya
    Tenzing, Emayah
    Velraj, Jaya
    ANNALS OF CARDIAC ANAESTHESIA, 2023, 26 (03) : 355 - 356
  • [48] COMPARISON OF 3 TECHNIQUES TO INFLATE THE BRONCHIAL CUFF OF LEFT POLYVINYLCHLORIDE (PVC) DOUBLE-LUMEN TUBES (DLT)
    HANNALLAH, M
    BENUMOF, J
    MCCARTHY, P
    LIANG, M
    ANESTHESIOLOGY, 1993, 79 (3A) : A1227 - A1227
  • [49] BRONCHIAL CHALLENGE TESTING: DIFFERENT HORSES FOR DIFFERENT COURSES
    Lexmond, A. J.
    Clarke, G. W.
    Page, C. P.
    Forbes, B.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2016, 29 (03) : A23 - A24
  • [50] BRONCHIAL CYTOLOGY - SIGNIFICANCE OF DIFFERENT METHODS FOR THE DIAGNOSIS OF PRIMARY BRONCHOGENIC CARCINOMA
    SPIELER, P
    JODER, P
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1979, 109 (22) : 824 - 827