Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film

被引:9
|
作者
Devic, Slobodan [1 ,2 ]
Liang, LiHeng [1 ,2 ]
Tomic, Nada [1 ,2 ]
Bekerat, Hamed [1 ,2 ]
Morcos, Marc [1 ,2 ,3 ]
Popovic, Marija [1 ,4 ]
Watson, Peter [1 ,4 ]
Aldelaijan, Saad [1 ,5 ,6 ]
Seuntjens, Jan [1 ,4 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[4] Montreal Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[5] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ, Canada
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
Electronic brachytherapy; Radiochromic film dosimetry; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigate the effect of the GafChromic (TM) film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Measurement strips of EBT3 film were positioned at distances of 2-6 cm from the Xoft source in a water phantom using a custom-made holder and irradiated simultaneously. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 5%. However, if the calibration curve was established in an MV beam quality, the error in absorbed dose could be as large as 20%. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at appropriate corresponding low energies, as large absorbed dose errors are expected when film calibration is performed in MV beam qualities.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [1] Impact of the Radiochromic Film Energy Response On Dose Measurements of Low Energy Electronic Brachytherapy Sources
    Liang, L.
    Bekerat, H.
    Tomic, N.
    DeBlois, F.
    Devic, S.
    Morcos, M.
    Popovic, M.
    Watson, P.
    Seuntjens, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3440 - 3441
  • [2] Quantitative assessment of RadioChromic film absolute dose measurements for low dose brachytherapy sources
    Le, Y
    Ali, I
    Williamson, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1912 - 1912
  • [3] Radiochromic film calibration for low-energy seed brachytherapy dose measurement
    Morrison, H.
    Menon, G.
    Sloboda, R.
    MEDICAL PHYSICS, 2014, 41 (08) : 15 - 16
  • [4] Radiochromic film calibration for low-energy seed brachytherapy dose measurement
    Morrison, Hali
    Menon, Geetha
    Sloboda, Ron S.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [5] Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements
    Sureka, C. S.
    Sunny, C. Sunil
    Subbaiah, K. V.
    Aruna, P.
    Ganesan, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : 525 - 537
  • [6] Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources
    Le, Yi
    Ali, Imad
    Dempsey, James F.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2006, 33 (12) : 4622 - 4634
  • [7] Radiochromic film dosimetry for a new electronic brachytherapy source
    Chiu-Tsao, S
    Rusch, T
    Axelrod, S
    Tsao, H
    Harrison, L
    MEDICAL PHYSICS, 2004, 31 (06) : 1913 - 1913
  • [8] In vivo dosimetry of high dose rate brachytherapy using an improved radiochromic film
    Parsai, E
    Feldmeier, J
    Ye, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206
  • [9] Measurement of dose enhancement factor for Xoft Axxent electronic brachytherapy device using nanoparticle-embedded alginate film and radiochromic film
    Kakade, Nitin R.
    Das, Abhishek
    Kumar, Rajesh
    Sharma, S. D.
    Maiti, Nandita
    Chadha, Ridhima
    Sapra, B. K.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (SUPPL 1) : S177 - S182
  • [10] Extrapolated surface dose measurements with radiochromic film
    City University of Hong Kong, Dept. of Phys. and Materials Science, Kowloon Tong, Hong Kong
    不详
    Med. Phys., 3 (485-488):