Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film

被引:9
|
作者
Devic, Slobodan [1 ,2 ]
Liang, LiHeng [1 ,2 ]
Tomic, Nada [1 ,2 ]
Bekerat, Hamed [1 ,2 ]
Morcos, Marc [1 ,2 ,3 ]
Popovic, Marija [1 ,4 ]
Watson, Peter [1 ,4 ]
Aldelaijan, Saad [1 ,5 ,6 ]
Seuntjens, Jan [1 ,4 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[4] Montreal Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[5] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ, Canada
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
Electronic brachytherapy; Radiochromic film dosimetry; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigate the effect of the GafChromic (TM) film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Measurement strips of EBT3 film were positioned at distances of 2-6 cm from the Xoft source in a water phantom using a custom-made holder and irradiated simultaneously. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 5%. However, if the calibration curve was established in an MV beam quality, the error in absorbed dose could be as large as 20%. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at appropriate corresponding low energies, as large absorbed dose errors are expected when film calibration is performed in MV beam qualities.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [21] Novel Film Calibration Method Directly Using Low Energy Brachytherapy Sources with a Custom Phantom
    Oare, C.
    Alshreef, A.
    Ferreira, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E820 - E821
  • [22] Radiochromic Film Based Dosimetry of Novel Rectal Electronic-Brachytherapy Applicator
    Liang, L.
    Tomic, N.
    Devic, S.
    Piccolo, F.
    Kelley, L.
    Furtado, T.
    Vuong, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E840 - E840
  • [23] Low Cost Radiochromic Film Based QA Device for Brachytherapy Afterloader
    Johnson, D.
    Richards, Z.
    Muller, L.
    Chen, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E811 - E811
  • [24] Dose heterogeneity correction for low-energy brachytherapy sources using dual-energy CT images
    Mashouf, S.
    Lechtman, E.
    Lai, P.
    Keller, B. M.
    Karotki, A.
    Beachey, D. J.
    Pignol, J. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5305 - 5316
  • [25] Radiochromic Film Based Reference Dosimetry System for 192Ir Brachytherapy Sources
    Aldelaijan, S.
    Mohammed, H.
    Tomic, N.
    Liang, L.
    Deblois, F.
    Sarfehnia, A.
    Abdel-Rahman, W.
    Seuntjens, J.
    Devic, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3574 - +
  • [26] Toward Absolute Dose Measuments Using Radiochromic Film
    Girard, F.
    Bouchard, H.
    Lacroix, F.
    MEDICAL PHYSICS, 2011, 38 (06) : 3507 - U124
  • [27] Absolute dose measurements using radiochromic films in 192Ir and 60Co HDR brachytherapy
    Oliver Canamas, Laura
    Jose Rovira-Escutia, Juan
    Vijande-Asenjo, Javier
    Candela-Juan, Cristian
    Gimeno-Olmos, Jose
    Carmen Pujades-Claumarchirant, Ma
    Angel Martinez-Navarro, Jose
    Zaragoza-Carrillo, Antonio
    Garcia-Cases, Francisco
    Ballester-Pallares, Facundo
    Perez-Calatayud, Jose
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S350 - S352
  • [28] Dosimetry and calibration of low-energy brachytherapy sources: Implications for dose prescription
    Williamson, JF
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 21 - 24
  • [29] The use of improved radiochromic film for in vivo quality assurance of high dose rate brachytherapy
    Pai, S
    Reinstein, LE
    Gluckman, G
    Xu, ZG
    Weiss, T
    MEDICAL PHYSICS, 1998, 25 (07) : 1217 - 1221
  • [30] A modified dose calculation formalism for electronic brachytherapy sources
    DeWerd, Larry A.
    Culberson, Wesley. S.
    Micka, John A.
    Simiele, Samantha J.
    BRACHYTHERAPY, 2015, 14 (03) : 405 - 408