Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film

被引:9
|
作者
Devic, Slobodan [1 ,2 ]
Liang, LiHeng [1 ,2 ]
Tomic, Nada [1 ,2 ]
Bekerat, Hamed [1 ,2 ]
Morcos, Marc [1 ,2 ,3 ]
Popovic, Marija [1 ,4 ]
Watson, Peter [1 ,4 ]
Aldelaijan, Saad [1 ,5 ,6 ]
Seuntjens, Jan [1 ,4 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[4] Montreal Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[5] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ, Canada
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
Electronic brachytherapy; Radiochromic film dosimetry; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigate the effect of the GafChromic (TM) film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Measurement strips of EBT3 film were positioned at distances of 2-6 cm from the Xoft source in a water phantom using a custom-made holder and irradiated simultaneously. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 5%. However, if the calibration curve was established in an MV beam quality, the error in absorbed dose could be as large as 20%. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at appropriate corresponding low energies, as large absorbed dose errors are expected when film calibration is performed in MV beam qualities.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [41] Verification of cell irradiation dose deposition using radiochromic film
    Tomic, N.
    Gosselin, M.
    Wan, J.
    Saragovi, U.
    Evans, M.
    Podgorsak, E.
    Devic, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2149 - 2149
  • [42] Quality management of low dose rate Brachytherapy sources
    Ezzell, Gary A.
    Brachytherapy Physics, Second Edition, 2005, (31): : 47 - 57
  • [43] Dose Distribution of Praseodymium-142 Microspheres in Microcapillary Using Radiochromic Film Dosimetry and Applications in Hepatocellular Carcinoma Microsphere Brachytherapy
    Ferreira, M.
    Rasmussen, K.
    Jung, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 248 - +
  • [44] The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources
    Landry, Guillaume
    Reniers, Brigitte
    Pignol, Jean-Philippe
    Beaulieu, Luc
    Verhaegen, Frank
    MEDICAL PHYSICS, 2011, 38 (03) : 1526 - 1533
  • [45] DOSE TO MEDIUM AND WATER IN LOW ENERGY BRACHYTHERAPY
    Landry, G.
    Pignol, J. P.
    Beaulieu, L.
    Verhaegen, F.
    Reniers, B.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S41 - S41
  • [46] Assessment of large single-fraction, low-energy X-ray dose with radiochromic film
    Butson, MJ
    Cheung, T
    Yu, PKN
    Metcalfe, PE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (04): : 1071 - 1075
  • [47] Validation of an electron Monte Carlo dose calculation algorithm in the presence of heterogeneities using EGSnrc and radiochromic film measurements
    Aubry, Jean-Francois
    Bouchard, Hugo
    Bessieres, Igor
    Lacroix, Frederic
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 2 - 14
  • [48] Radiochromic film dosimetry of rectal inhomogeneity and applicator attenuation in high dose rate brachytherapy of uterine cervix
    Uniyal, Satish C.
    Naithani, Umesh C.
    Sharma, Sunil D.
    Srivastava, Anoop K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 66 - 75
  • [49] A Comparison of Surface Dose Values Using Radiochromic Film Measurements and Treatment Plans Calculated with Different Calculation Algorithms
    Kaptan, I.
    Akdeniz, Y.
    Ispir, B.
    Ugurluer, G.
    Serin, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3074 - 3074
  • [50] OUTDOOR SOLAR UVA DOSE ASSESSMENT WITH EBT2 RADIOCHROMIC FILM USING SPECTROPHOTOMETER AND DENSITOMETER MEASUREMENTS
    Abukassem, I.
    Bero, M. A.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 335 - 341