Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources

被引:9
|
作者
Le, Yi
Ali, Imad
Dempsey, James F.
Williamson, Jeffrey F.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
dosimetry; low dose-rate; brachytherapy; Monte Carlo; radiochromic film (RCF);
D O I
10.1118/1.2390546
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiochromic film (RCF) has been shown to be a precise and accurate two-dimensional dosimeter for acute exposure radiation fields. However, "temporal history" mismatch between calibration and brachytherapy films due to RCF dose-rate effects could introduce potentially large uncertainties in low dose-rate (LDR) brachytherapy absolute dose measurement. This article presents a quantitative evaluation of the precision and accuracy of a laser scanner-based RCF-dosimetry system and the effect of the temporal history mismatch in LDR absolute dose measurement. MD-55-2 RCF was used to measure absolute dose for a low dose-rate Cs-137 brachytherapy source using both single-and double-exposure techniques. Dose-measurement accuracy was evaluated by comparing RCF to Monte Carlo photon-transport simulation. The temporal history mismatch effect was investigated by examining dependence of RCF accuracy on irradiation-to-densitometry time interval. The predictions of the empirical cumulative dose superposition model (CDSM) were compared with measurements. For the double-exposure technique, the agreement between measurement and Monte Carlo simulation was better than 4% in the 3-60 Gy dose range with measurement precisions (coverage factor k=1) of < 2% and < 6% for the doses greater or less than 3 Gy, respectively. The overall uncertainty (k=1) of dose rate/air-kerma strength measurements achievable by this dosimeter system for a spatial resolution of 0.1 mm is less than 4% for doses greater than 5 Gy. The measured temporal history mismatch systematic error is about 1.8% for a 48 h postexposure time when using the double exposure technique and agrees with CDSM's prediction qualitatively. This work demonstrates that the model MD-55-2 RCF detector has the potential to support quantitative dose measurements about LDR brachytherapy sources with precision and accuracy better than that of previously described dosimeters. The impacts of this work on the future use of new type of RCF were also discussed. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4622 / 4634
页数:13
相关论文
共 50 条
  • [1] Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    Zhu, YM
    Kirov, AS
    Mishra, V
    Meigooni, AS
    Williamson, JF
    MEDICAL PHYSICS, 1997, 24 (02) : 223 - 231
  • [2] Quantitative assessment of RadioChromic film absolute dose measurements for low dose brachytherapy sources
    Le, Y
    Ali, I
    Williamson, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1912 - 1912
  • [3] Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions
    Dempsey, JF
    Low, DA
    Mutic, S
    Markman, J
    Kirov, AS
    Nussbaum, GH
    Williamson, JF
    MEDICAL PHYSICS, 2000, 27 (10) : 2462 - 2475
  • [4] Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy
    Duggan, DM
    Coffey, CW
    Lobdell, JL
    Schell, MC
    MEDICAL PHYSICS, 1999, 26 (11) : 2461 - 2464
  • [5] In vivo dosimetry of high dose rate brachytherapy using an improved radiochromic film
    Parsai, E
    Feldmeier, J
    Ye, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206
  • [6] High dose-rate brachytherapy source position quality assurance using radiochromic film
    Evans, M. D. C.
    Devic, S.
    Podgorsak, E. B.
    MEDICAL DOSIMETRY, 2007, 32 (01) : 13 - 15
  • [7] Dosimetric Evaluation of An Endorectal Balloon with Radiochromic Film for Two-Dimensional in Vivo Rectal Dosimetry During Cervical Cancer Brachytherapy
    Goh, Y.
    Jeang, E.
    Cho, K.
    Min, S.
    Hwang, U.
    Choi, S.
    Lee, N.
    Song, S.
    Lee, S.
    Shin, D.
    Kim, Y.
    Kim, D.
    Lim, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [8] Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film
    Devic, Slobodan
    Liang, LiHeng
    Tomic, Nada
    Bekerat, Hamed
    Morcos, Marc
    Popovic, Marija
    Watson, Peter
    Aldelaijan, Saad
    Seuntjens, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 40 - 44
  • [9] Radiochromic film dosimetry of rectal inhomogeneity and applicator attenuation in high dose rate brachytherapy of uterine cervix
    Uniyal, Satish C.
    Naithani, Umesh C.
    Sharma, Sunil D.
    Srivastava, Anoop K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 66 - 75
  • [10] High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer
    Ghadjar, Pirus
    Bojaxhiu, Beat
    Simcock, Mathew
    Terribilini, Dario
    Isaak, Bernhard
    Gut, Philipp
    Wolfensberger, Patrick
    Broemme, Jens O.
    Geretschlaeger, Andreas
    Behrensmeier, Frank
    Pica, Alessia
    Aebersold, Daniel M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : 1205 - 1212