Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources

被引:9
|
作者
Le, Yi
Ali, Imad
Dempsey, James F.
Williamson, Jeffrey F.
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
dosimetry; low dose-rate; brachytherapy; Monte Carlo; radiochromic film (RCF);
D O I
10.1118/1.2390546
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiochromic film (RCF) has been shown to be a precise and accurate two-dimensional dosimeter for acute exposure radiation fields. However, "temporal history" mismatch between calibration and brachytherapy films due to RCF dose-rate effects could introduce potentially large uncertainties in low dose-rate (LDR) brachytherapy absolute dose measurement. This article presents a quantitative evaluation of the precision and accuracy of a laser scanner-based RCF-dosimetry system and the effect of the temporal history mismatch in LDR absolute dose measurement. MD-55-2 RCF was used to measure absolute dose for a low dose-rate Cs-137 brachytherapy source using both single-and double-exposure techniques. Dose-measurement accuracy was evaluated by comparing RCF to Monte Carlo photon-transport simulation. The temporal history mismatch effect was investigated by examining dependence of RCF accuracy on irradiation-to-densitometry time interval. The predictions of the empirical cumulative dose superposition model (CDSM) were compared with measurements. For the double-exposure technique, the agreement between measurement and Monte Carlo simulation was better than 4% in the 3-60 Gy dose range with measurement precisions (coverage factor k=1) of < 2% and < 6% for the doses greater or less than 3 Gy, respectively. The overall uncertainty (k=1) of dose rate/air-kerma strength measurements achievable by this dosimeter system for a spatial resolution of 0.1 mm is less than 4% for doses greater than 5 Gy. The measured temporal history mismatch systematic error is about 1.8% for a 48 h postexposure time when using the double exposure technique and agrees with CDSM's prediction qualitatively. This work demonstrates that the model MD-55-2 RCF detector has the potential to support quantitative dose measurements about LDR brachytherapy sources with precision and accuracy better than that of previously described dosimeters. The impacts of this work on the future use of new type of RCF were also discussed. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4622 / 4634
页数:13
相关论文
共 50 条
  • [21] RADIOCHROMIC FILM DOSIMETRY OF A NEW HIGH DOSE RATE (HDR) APPLICATOR
    Hariri, S.
    Aghamiri, M. R.
    Najarian, S.
    Jaberi, R.
    Dehghan, H. R.
    Azmi, M.
    Hajizadeh, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S45 - S45
  • [22] High and low dose-rate brachytherapy for cervical carcinoma
    Orton, CG
    ACTA ONCOLOGICA, 1998, 37 (02) : 117 - 125
  • [23] Pulsed low dose-rate radiotherapy: radiobiology and dosimetry
    Ma, C. M. Charlie
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03):
  • [24] Dose-rate dependence and IMRT QA suitability of EBT3 radiochromic films for pulse reduced dose-rate radiotherapy (PRDR) dosimetry
    Khan, Ahtesham Ullah
    Radtke, Jeff
    Hammer, Clifford
    Malyshev, Julia
    Morris, Brett
    Glide-Hurst, Carri
    Dewerd, Larry
    Culberson, Wesley
    Bayliss, Adam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):
  • [25] Radiochromic Films for the Two-Dimensional Dose Distribution Assessment
    Casolaro, Pierluigi
    APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 16
  • [26] Quantitative Analysis and Quality Assurance (QA) of Gynecological Brachytherapy Applicators Using Radiochromic Film Dosimetry
    Aldelaijan, S.
    Khouj, Y.
    Khosravi, M.
    Harris, T.
    O'Farrell, D.
    Jacobson, M.
    Seuntjens, J.
    Devic, S.
    Buzurovic, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E838 - E838
  • [27] The impact of modern imaging on low dose-rate prostate brachytherapy
    Lamb, D.
    Greig, L.
    Russell, G.
    Nacey, J.
    Woods, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S70 - S71
  • [28] Two-dimensional in vivo rectal dosimetry during high-dose-rate brachytherapy for cervical cancer: a phantom study
    Jeang, Eun Hee
    Goh, Youngmoon
    Cho, Kwan Ho
    Min, Soonki
    Choi, Sang Hyoun
    Jeong, Hojin
    Jo, Kwanghyun
    Lee, Nuri
    Song, Sanghyeon
    Lee, Se Byeong
    Shin, Dongho
    Kim, Yeon-Joo
    Kim, Joo-Young
    Kim, Dae Yong
    Hwang, Ui-Jung
    Lim, Young Kyung
    ACTA ONCOLOGICA, 2018, 57 (10) : 1359 - 1366
  • [29] Radiochromic film calibration for low-energy seed brachytherapy dose measurement
    Morrison, H.
    Menon, G.
    Sloboda, R.
    MEDICAL PHYSICS, 2014, 41 (08) : 15 - 16
  • [30] FRACTIONATED HIGH DOSE-RATE VERSUS LOW DOSE-RATE REGIMENS FOR INTRACAVITARY BRACHYTHERAPY OF THE CERVIX - EQUIVALENT REGIMENS FOR COMBINED BRACHYTHERAPY AND EXTERNAL IRRADIATION
    BRENNER, DJ
    HUANG, Y
    HALL, EJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06): : 1415 - 1423