Dosimetry inside MIR station using a silicon detector telescope (DOSTEL)

被引:31
|
作者
Beaujean, R [1 ]
Kopp, J
Burmeister, S
Peterson, F
Reitz, G
机构
[1] Univ Kiel, Inst Expt & Angew Phys, D-24109 Kiel, Germany
[2] DLR, Inst Luft & Raumfahrtmed Strahlenbiol, D-51140 Cologne, Germany
关键词
space flights; active dosimetry; silicon detectors; dose equivalent; LET-spectra;
D O I
10.1016/S1350-4487(02)00074-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dosimetry telescope (DOSTEL)was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 muGy/d and 121 +/- 13 muGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:433 / 438
页数:6
相关论文
共 50 条
  • [41] Calibration of an amorphous-silicon flat panel detector for absolute dosimetry
    Chen, J
    Chuang, C
    Morin, O
    Aubin, M
    Pouliot, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1831 - 1832
  • [42] Silicon Detector Telescope for proton detection in electron scattering reactions at MAMI
    Makek, M.
    Achenbach, P.
    Gayoso, C. Ayerbe
    Baumann, D.
    Bernauer, J. C.
    Boehm, R.
    Bosnar, D.
    Denig, A.
    Ding, M.
    Distler, M. O.
    Doria, L.
    Friedrich, J.
    Friscic, I.
    de la Paz, M. Gomez Rodriguez
    Merkel, H.
    Mueller, U.
    Nungesser, L.
    Pochodzalla, J.
    Potokar, M.
    Seimetz, M.
    Majos, S. Sanchez
    Schlimme, B. S.
    Sirca, S.
    Walcher, Th.
    Weinriefer, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 673 : 82 - 88
  • [43] A new monolithic silicon detector telescope with bidimensional sensitivity for imaging applications
    Amorini, F.
    Sipala, V.
    Cardella, G.
    Auditore, L.
    Boiano, C.
    Carbone, B.
    Castoldi, A.
    Di Pietro, A.
    Fallica, G.
    Figuera, P.
    Finocchiaro, P.
    Grassi, L.
    La Guidara, E.
    Guazzoni, C.
    Guazzoni, P.
    Lombardo, I.
    Loria, D.
    Pappalardo, A.
    Pirrone, S.
    Randazzo, N.
    Rizzo, F.
    Russo, G. V.
    Russotto, P.
    Scire, C.
    Scire, S.
    Trifiro, A.
    Trimarchi, M.
    Valvo, G.
    Zetta, L.
    NUCLEAR PHYSICS A, 2010, 834 (1-4) : 758C - 760C
  • [44] A SILICON STRIP DETECTOR TELESCOPE FOR THE MEASUREMENT OF PRODUCTION AND DECAY OF CHARMED PARTICLES
    BAILEY, R
    BELAU, ER
    BOHRINGER, T
    BOSMAN, M
    CHABAUD, V
    DAMERELL, C
    DAUM, C
    DERIJK, G
    DIJKSTRA, H
    DWURAZNY, A
    GILL, S
    GILLMAN, A
    GILMORE, R
    GORLICH, L
    HAJDUK, Z
    HARDWICK, C
    HOOGLAND, W
    HYAMS, BD
    KEMMER, J
    KLANNER, R
    KOTZ, U
    LUTJENS, G
    LUTZ, G
    MALOS, J
    MANNER, W
    NEUGEBAUER, E
    POLOK, G
    ROZANSKA, M
    RYBICKI, K
    SEEBRUNNER, HJ
    STIERLIN, U
    TAPPER, RJ
    TIECKE, HG
    TURALA, M
    WALTERMANN, G
    WEILHAMMER, P
    WICKENS, F
    WIGGERS, LW
    WYLIE, A
    ZELUDZIEWICZ, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 56 - 58
  • [45] Radiation measurements inside a human phantom aboard the International Space Station using Liulin-5 charged particle telescope
    Semkova, J.
    Koleva, R.
    Maltchev, St.
    Kanchev, N.
    Benghin, V.
    Chernykh, I.
    Shurshakov, V.
    Petrov, V.
    Yarmanova, E.
    Bankov, N.
    Lyagushin, V.
    Goranova, M.
    ADVANCES IN SPACE RESEARCH, 2010, 45 (07) : 858 - 865
  • [46] Beta ray spectroscopy based on a plastic scintillation detector/silicon surface barrier detector coincidence telescope
    Horowitz, Y.S.
    Hirning, C.R.
    Yuen, P.
    Aikens, M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A338 (2-3) : 522 - 533
  • [47] PRECISE POINTING OF SPACE TELESCOPE USING A QUADRANT DETECTOR
    STRIKWERDA, TE
    STROHBEHN, K
    HEYLER, GA
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 550 : 51 - 57
  • [48] IN-VIVO DOSIMETRY USING A DIODE DETECTOR SYSTEM
    PODGORSAK, MB
    BALOG, JP
    SIBATA, CH
    HO, AK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (02): : 556 - 557
  • [49] TEMPERATURE-DEPENDENCE OF TIME RESOLUTION AND ELECTRONIC NOISE IN A SILICON DETECTOR TELESCOPE
    CODINO, A
    FEDERICO, C
    GRIMANI, C
    MACCHIAIOLO, T
    MENICHELLI, M
    MINELLI, G
    MIOZZA, M
    BRUNETTI, MT
    PLOUIN, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 361 (1-2): : 216 - 221
  • [50] SILICON STRIP DETECTOR TELESCOPE FOR THE MEASUREMENT OF PRODUCTION AND DECAY OF CHARMED PARTICLES.
    Bailey, R.
    Belau, E.R.
    Bohringer, T.
    Bosman, M.
    Chabaud, V.
    Damerell, C.
    Daum, C.
    de Rijk, G.
    Dijkstra, H.
    Dwurazny, A.
    Gill, S.
    Gillman, A.
    Gilmore, R.
    Gorlich, L.
    Hajduk, Z.
    Nuclear instruments and methods in physics research, 1983, 226 (01): : 56 - 58