Dosimetry inside MIR station using a silicon detector telescope (DOSTEL)

被引:31
|
作者
Beaujean, R [1 ]
Kopp, J
Burmeister, S
Peterson, F
Reitz, G
机构
[1] Univ Kiel, Inst Expt & Angew Phys, D-24109 Kiel, Germany
[2] DLR, Inst Luft & Raumfahrtmed Strahlenbiol, D-51140 Cologne, Germany
关键词
space flights; active dosimetry; silicon detectors; dose equivalent; LET-spectra;
D O I
10.1016/S1350-4487(02)00074-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dosimetry telescope (DOSTEL)was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 muGy/d and 121 +/- 13 muGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:433 / 438
页数:6
相关论文
共 50 条
  • [21] Personal neutron dosimetry in the space station MIR and the space shuttle
    Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
    不详
    不详
    Radiat. Meas., 1 (425-430):
  • [22] Passive dosimetry aboard the Mir Orbital Station: Internal measurements
    Benton, Eric R.
    Benton, E.V.
    Frank, A.L.
    2002, Elsevier Ltd (35)
  • [23] P-TYPE SILICON DETECTOR FOR BRACHYTHERAPY DOSIMETRY
    PIERMATTEI, A
    AZARIO, L
    MONACO, G
    SORIANI, A
    ARCOVITO, G
    MEDICAL PHYSICS, 1995, 22 (06) : 835 - 839
  • [24] Development of a silicon diode detector for skin dosimetry in radiotherapy
    Vicoroski, Nikolina
    Espinoza, Anthony
    Duncan, Mitchell
    Oborn, Bradley M.
    Carolan, Martin
    Metcalfe, Peter
    Menichelli, David
    Perevertaylo, Vladimir L.
    Lerch, Michael L. F.
    Rosenfeld, Anatoly B.
    Petasecca, Marco
    MEDICAL PHYSICS, 2017, 44 (10) : 5402 - 5412
  • [25] The Pixel Luminosity Telescope: a detector for luminosity measurement at CMS using silicon pixel sensors
    Ayala, E.
    Jarrin, E. Carrera
    Ahmed, I.
    Campbell, A.
    Danilov, V.
    Banos, L. I. Estevez
    Giraldi, A.
    Guthoff, M.
    Hempel, M.
    Henschel, H.
    Knolle, J.
    Lange, W.
    Leonard, J.
    Lohmann, W.
    Meyer, A. B.
    Myronenko, V.
    Penno, M.
    Ribeiro Lopes, B.
    Ruebenach, J.
    Saggio, A.
    Scheurer, V.
    Sosa Ricardo, R. E.
    Turkot, O.
    Walter, D.
    Kassel, F.
    Mallows, S.
    Bartok, M.
    Chudasama, R.
    Farkas, K.
    Fejes, M.
    Gadallah, M. M. A.
    Major, P.
    Mehta, A.
    Pasztor, G.
    Radl, A. J.
    Veres, G. I.
    Bakhshiansohi, H.
    Gholami, A.
    Khazaie, E.
    Sedghi, M.
    Zeinali, M.
    Fabbri, F.
    Tosi, N.
    Bacchetta, N.
    Trapani, P. P.
    Daugalas, J.
    Benitez, J. F.
    Castaneda Hernandez, A.
    Encinas Acosta, H. A.
    Gallegos Marinez, L. G.
    EUROPEAN PHYSICAL JOURNAL C, 2023, 83 (07):
  • [26] The Pixel Luminosity Telescope: a detector for luminosity measurement at CMS using silicon pixel sensors
    E. Ayala
    E. CarreraJarrin
    I. Ahmed
    A. Campbell
    V. Danilov
    L. I. EstevezBanos
    A. Giraldi
    M. Guthoff
    M. Hempel
    H. Henschel
    J. Knolle
    W. Lange
    J. Leonard
    W. Lohmann
    A. B. Meyer
    V. Myronenko
    M. Penno
    B. Ribeiro Lopes
    J. Rübenach
    A. Saggio
    V. Scheurer
    R. E. Sosa Ricardo
    O. Turkot
    D. Walter
    F. Kassel
    S. Mallows
    M. Bartók
    R. Chudasama
    K. Farkas
    M. Fejes
    M. M. A. Gadallah
    P. Major
    A. Mehta
    G. Pásztor
    A. J. Rádl
    G. I. Veres
    H. Bakhshiansohi
    A. Gholami
    E. Khazaie
    M. Sedghi
    M. Zeinali
    F. Fabbri
    N. Tosi
    N. Bacchetta
    P. P. Trapani
    J. Daugalas
    J. F. Benitez
    A. Castaneda Hernandez
    H. A. Encinas Acosta
    L. G. Gallegos Maríñez
    The European Physical Journal C, 83
  • [27] LOW-ENERGY ION IDENTIFICATION METHOD USING A SILICON SEMICONDUCTOR DETECTOR TELESCOPE
    DELPERAL, L
    MEDINA, J
    BRONCHALO, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (01): : 192 - 197
  • [28] Exploiting different active silicon detectors in the International Space Station: ALTEA and DOSTEL galactic cosmic radiation (GCR) measurements
    Narici, Livo
    Berger, Thomas
    Burmeister, Sonke
    Di Fino, Luca
    Rizzo, Alessandro
    Matthiae, Daniel
    Reitz, Guenther
    JOURNAL OF SPACE WEATHER AND SPACE CLIMATE, 2017, 7
  • [29] Monte Carlo studies on proton computed tomography using a silicon strip detector telescope
    Johnson, LR
    Keeney, B
    Ross, G
    Sadrozinski, HEW
    Seiden, A
    Williams, DC
    Zhang, L
    Bashkirov, V
    Schulte, RW
    Shahnazi, K
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 916 - 920
  • [30] PASSIVE DOSIMETRY USING DETECTOR TUBES
    HILL, RH
    FRASER, DA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (10): : 721 - 729