Dosimetry inside MIR station using a silicon detector telescope (DOSTEL)

被引:31
|
作者
Beaujean, R [1 ]
Kopp, J
Burmeister, S
Peterson, F
Reitz, G
机构
[1] Univ Kiel, Inst Expt & Angew Phys, D-24109 Kiel, Germany
[2] DLR, Inst Luft & Raumfahrtmed Strahlenbiol, D-51140 Cologne, Germany
关键词
space flights; active dosimetry; silicon detectors; dose equivalent; LET-spectra;
D O I
10.1016/S1350-4487(02)00074-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dosimetry telescope (DOSTEL)was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 muGy/d and 121 +/- 13 muGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:433 / 438
页数:6
相关论文
共 50 条
  • [31] THE MARK-II SILICON STRIP VERTEX DETECTOR AND PERFORMANCE OF A SILICON DETECTOR TELESCOPE IN THE MARK-II DETECTOR AT THE SLC
    LABARGA, L
    ADOLPHSEN, C
    GRATTA, G
    LITKE, A
    TURALA, M
    ZACCARDELLI, C
    BREAKSTONE, A
    PARKER, S
    BARNETT, B
    DAUNCEY, P
    DREWER, D
    MATTHEWS, J
    JACOBSEN, R
    LUTH, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (01) : 25 - 29
  • [32] Measurements of beta ray spectra inside nuclear generating stations using a silicon detector coincidence telescope: Skin dose beta correction factors for TL elements
    Horowitz, YS
    Weizman, Y
    Hirning, CR
    RADIATION PROTECTION DOSIMETRY, 1996, 64 (03) : 193 - 204
  • [33] A silicon strip detector dose magnifying glass for IMRT dosimetry
    Wong, J. H. D.
    Carolan, M.
    Lerch, M. L. F.
    Petasecca, M.
    Khanna, S.
    Perevertaylo, V. L.
    Metcalfe, P.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2010, 37 (02) : 427 - 439
  • [34] Gas-silicon detector telescope for charged particle spectroscopy
    Honkanen, A
    Oinonen, M
    Eskola, K
    Jokinen, A
    Aysto, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (02): : 217 - 225
  • [35] Preliminary results on a dedicated silicon diode detector for proton dosimetry
    De Angelis, C
    Onori, S
    Pacilio, M
    Cirrone, GAP
    Cuttone, G
    Raffaele, L
    Sabini, MG
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 461 - 464
  • [36] Preliminary results on a dedicated silicon diode detector for proton dosimetry
    De Angelis, C
    Onori, S
    Pacilio, M
    Cirrone, GAP
    Cuttone, G
    Raffaele, L
    Sabini, MG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A461 - A464
  • [37] Yield Function of the DOSimetry TELescope Count and Dose Rates Aboard the International Space Station
    Caprotti, A. S.
    Bruedern, M.
    Burmeister, S.
    Heber, B.
    Herbst, K.
    SPACE WEATHER-THE INTERNATIONAL JOURNAL OF RESEARCH AND APPLICATIONS, 2021, 19 (05):
  • [38] Angular independent silicon detector for dosimetry in external beam radiotherapy
    Petasecca, M.
    Alhujaili, S.
    Aldosari, A. H.
    Fuduli, I.
    Newall, M.
    Porumb, C. S.
    Carolan, M.
    Nitschke, K.
    Lerch, M. L. F.
    Kalliopuska, J.
    Perevertaylo, V.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2015, 42 (08) : 4708 - 4718
  • [39] FLAW DETECTOR FOR THE INSIDE SURFACES OF PIPES IN A NUCLEAR-POWER STATION
    MADOYAN, AA
    KANTSEDALOV, VG
    SAMOILENKO, VP
    SAMOILENKO, PB
    SOVIET ATOMIC ENERGY, 1982, 53 (01): : 465 - 468
  • [40] Measurements of beta ray spectra in CANDU nuclear generating stations using a silicon detector coincidence telescope
    Horowitz, YS
    Weizman, Y
    Hirning, CR
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 97 - 100