Evaluation of the Abbott m2000rt RealTime™ HIV-1 assay with manual sample preparation compared with the ROCHE COBAS® AmpliPrep™/AMPLICOR™ HIV-1 MONITOR® v1.5 using specimens from East Africa

被引:31
|
作者
Crump, John A. [1 ,2 ,3 ,4 ]
Scott, Lesley E. [5 ]
Msuya, Emma [3 ]
Morrissey, Anne B. [1 ]
Kimaro, Ekyafyose E. [3 ]
Shao, John F. [3 ,4 ]
Stevens, Wendy S. [5 ,6 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Infect Dis & Int Health, Durham, NC 27710 USA
[2] Duke Univ, Duke Global Hlth Inst, Durham, NC 27710 USA
[3] Kilimanjaro Christian Med Ctr, Moshi, Tanzania
[4] Tumaini Univ, Kilimanjaro Christian Med Coll, Moshi, Tanzania
[5] Univ Witwatersrand, Dept Mol Med & Haematol, Sch Pathol, Fac Hlth Sci, ZA-2050 Wits, South Africa
[6] Natl Hlth Lab Serv, Johannesburg, South Africa
基金
美国国家卫生研究院;
关键词
HIV; Reverse transcriptase polymerase chain reaction; Viral load; Validation studies; Tanzania; GENETICALLY DIVERSE PANEL; DRIED BLOOD SPOTS; VIRUS TYPE-1 RNA; QUANTITATIVE DETECTION; PERFORMANCE; NUCLISENS; PLASMA; TANZANIA; PCR; QUANTIFICATION;
D O I
10.1016/j.jviromet.2009.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of the Abbott m2000rt RealTime (TM) HIV-1 assay (RealTime HIV-1) with manual sample preparation was compared against the ROCHE COBAS (R) AmpliPrep (TM)/AMPLICOR (TM) HIV-1 MONITOR Test v0.5 (CAP/CA HIV-1) using samples collected from 100 donors infected with HIV and 20 donors not infected with HIV in northern Tanzania where HIV-1 subtypes A, C, D, and their recombinant forms predominate. The RealTime HIV-1 appeared to have more within-run variability at high HIV-1 RNA concentrations, but total assay variability over the dynamic range tested was within the manufacturer's claim of < 0.3 SD copies/mL Accuracy studies showed 100% concordance for positive and negative values. When continuous values were examined, CAP/CA HIV-1 yielded higher values than the RealTime HIV-1 at higher nominal HIV-1 RNA concentrations. The RealTime HIV-1 assay showed excellent linearity between 2.5 and 7.0 log copies/mL Of negative samples, 100% showed negative results, and > 95% of samples with nominal concentrations of 40 copies/mL were detected at >= 40 copies/mL by RealTime HIV-1. Manual sample preparation may contribute to higher total assay variability. This study suggests that the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation is an acceptable and feasible alternative to the conventional ROCHE COBAS AmpliPrep/AMLICOR HIV-1 Monitor v1.5 assay and that the RealTime HIV-1 assay performs well on samples from East Africa. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 43 条
  • [31] Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya
    Zeh, Clement
    Ndiege, Kenneth
    Inzaule, Seth
    Achieng, Rebecca
    Williamson, John
    Chang, Joy Chih-Wei
    Ellenberger, Dennis
    Nkengasong, John
    PLOS ONE, 2017, 12 (06):
  • [32] Comparative evaluation of the Aptima HIV-1 Quant Dx assay and COBAS TaqMan HIV-1 v2.0 assay using the Roche High Pure System for the quantification of HIV-1 RNA in plasma
    Schalasta, Gunnar
    Boerner, Anna
    Speicher, Andrea
    Enders, Martin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (03) : 493 - 499
  • [33] Comparison of the Generic HIV Viral Load® assay with the Amplicor™ HIV-1 Monitor v1.5 and Nuclisens HIV-1 EasyQ® v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: The Kesho Bora preparatory study
    Rouet, Francois
    Foulongne, Vincent
    Viljoen, Johannes
    Steegen, Kim
    Becquart, Pierre
    Valea, Diane
    Danaviah, Sivapragashini
    Segondy, Michel
    Verhofstede, Chris
    Van de Perre, Philippe
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 253 - 257
  • [34] Comparative evaluation of the QUANTIPLEX HIV-1 RNA 2.0 and 3.0 (bDNA) assays and the AMPLICOR HIV-1 MONITOR v1.5 test for the quantitation of human immunodeficiency virus type 1 RNA in plasma
    Anastassopoulou, CG
    Toulomi, G
    Katsoulidou, A
    Hatzitheodorou, H
    Pappa, M
    Paraskevis, D
    Lazanas, M
    Gargalianos, P
    Hatzakis, A
    JOURNAL OF VIROLOGICAL METHODS, 2001, 91 (01) : 67 - 74
  • [35] Field evaluation of Abbott Real Time HIV-1 Qualitative test for early infant diagnosis using dried blood spots samples in comparison to Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qual Test in Kenya
    Chang, Joy
    Omuomo, Kenneth
    Anyango, Emily
    Kingwara, Leonard
    Basiye, Frank
    Morwabe, Alex
    Shanmugam, Vedapuri
    Shon Nguyen
    Sabatier, Jennifer
    Zeh, Clement
    Ellenberger, Dennis
    JOURNAL OF VIROLOGICAL METHODS, 2014, 204 : 25 - 30
  • [36] Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots
    Maritz, Jean
    Preiser, Wolfgang
    van Zyl, Gert U.
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (02) : 106 - 109
  • [37] Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay
    Vidya, Madhavan
    Saravanan, Shanmugam
    Rifkin, Samara
    Solomon, Sunil S.
    Waldrop, Greer
    Mayer, Kenneth H.
    Solomon, Suniti
    Balakrishnan, Pachamuthu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 181 (02) : 177 - 181
  • [38] Experiences using Roche COBAS AmpliScreen HCV test v2.0/HIV-1 test v1.5 nucleic acid amplification testing in volunteer blood donations for 2001.
    Tiongson, GO
    Holland, P
    Bonney, EN
    Aceituno, S
    Puth, P
    Chadwell, GE
    TRANSFUSION, 2002, 42 (09) : 136S - 136S
  • [39] Evaluation of Effect of Specimen-Handling Parameters for Plasma Preparation Tubes on Viral Load Measurements Obtained by Using the Abbott RealTime HIV-1 Load Assay
    Fernandes, Helen
    Morosyuk, Svetlana
    Abravaya, Klara
    Ramanathan, Madhuri
    Rainen, Lynne
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (07) : 2464 - 2468
  • [40] Measures of viral load using Abbott RealTime HIV-1 Assay on venous and fingerstick dried blood spots from provider-collected specimens in Malawian District Hospitals
    Rutstein, Sarah E.
    Kamwendo, Deborah
    Lugali, Lebah
    Thengolose, Isaac
    Tegha, Gerald
    Fiscus, Susan A.
    Nelson, Julie A. E.
    Hosseinipour, Mina C.
    Sarr, Abdoulaye
    Gupta, Sundeep
    Chimbwandira, Frank
    Mwenda, Reuben
    Mataya, Ronald
    JOURNAL OF CLINICAL VIROLOGY, 2014, 60 (04) : 392 - 398