Evaluation of the Abbott m2000rt RealTime™ HIV-1 assay with manual sample preparation compared with the ROCHE COBAS® AmpliPrep™/AMPLICOR™ HIV-1 MONITOR® v1.5 using specimens from East Africa

被引:31
|
作者
Crump, John A. [1 ,2 ,3 ,4 ]
Scott, Lesley E. [5 ]
Msuya, Emma [3 ]
Morrissey, Anne B. [1 ]
Kimaro, Ekyafyose E. [3 ]
Shao, John F. [3 ,4 ]
Stevens, Wendy S. [5 ,6 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Infect Dis & Int Health, Durham, NC 27710 USA
[2] Duke Univ, Duke Global Hlth Inst, Durham, NC 27710 USA
[3] Kilimanjaro Christian Med Ctr, Moshi, Tanzania
[4] Tumaini Univ, Kilimanjaro Christian Med Coll, Moshi, Tanzania
[5] Univ Witwatersrand, Dept Mol Med & Haematol, Sch Pathol, Fac Hlth Sci, ZA-2050 Wits, South Africa
[6] Natl Hlth Lab Serv, Johannesburg, South Africa
基金
美国国家卫生研究院;
关键词
HIV; Reverse transcriptase polymerase chain reaction; Viral load; Validation studies; Tanzania; GENETICALLY DIVERSE PANEL; DRIED BLOOD SPOTS; VIRUS TYPE-1 RNA; QUANTITATIVE DETECTION; PERFORMANCE; NUCLISENS; PLASMA; TANZANIA; PCR; QUANTIFICATION;
D O I
10.1016/j.jviromet.2009.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of the Abbott m2000rt RealTime (TM) HIV-1 assay (RealTime HIV-1) with manual sample preparation was compared against the ROCHE COBAS (R) AmpliPrep (TM)/AMPLICOR (TM) HIV-1 MONITOR Test v0.5 (CAP/CA HIV-1) using samples collected from 100 donors infected with HIV and 20 donors not infected with HIV in northern Tanzania where HIV-1 subtypes A, C, D, and their recombinant forms predominate. The RealTime HIV-1 appeared to have more within-run variability at high HIV-1 RNA concentrations, but total assay variability over the dynamic range tested was within the manufacturer's claim of < 0.3 SD copies/mL Accuracy studies showed 100% concordance for positive and negative values. When continuous values were examined, CAP/CA HIV-1 yielded higher values than the RealTime HIV-1 at higher nominal HIV-1 RNA concentrations. The RealTime HIV-1 assay showed excellent linearity between 2.5 and 7.0 log copies/mL Of negative samples, 100% showed negative results, and > 95% of samples with nominal concentrations of 40 copies/mL were detected at >= 40 copies/mL by RealTime HIV-1. Manual sample preparation may contribute to higher total assay variability. This study suggests that the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation is an acceptable and feasible alternative to the conventional ROCHE COBAS AmpliPrep/AMLICOR HIV-1 Monitor v1.5 assay and that the RealTime HIV-1 assay performs well on samples from East Africa. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 43 条
  • [21] Comparing Abbott m2000 RealTime HIV test and Roche COBAS Ampliprep/COBAS Taqman HIV test, v2.0 in treated HIV-1 B and non-B subjects with low viraemia
    Margariti, Apostolia
    Chatzidimitriou, Dimitrios
    Metallidis, Simeon
    Pilalas, Dimitrios
    Kourelis, Andreas
    Papadimitriou, Evangelia
    Haidich, Anna-Bettina
    Malisiovas, Nicolaos
    Skoura, Lemonia
    JOURNAL OF MEDICAL VIROLOGY, 2016, 88 (04) : 724 - 727
  • [22] Classification of HIV-1 virological treatment failure using the Roche cobas plasma separation card on cobas 8800 compared to dried blood spots on Abbott RealTime HIV-1
    Hans, Lucia
    Marins, Ed G.
    Simon, Christian O.
    Magubane, Dieketseng
    Seiverth, Britta
    Carmona, Sergio
    JOURNAL OF CLINICAL VIROLOGY, 2021, 140
  • [23] Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants
    Mourez, Thomas
    Delaugerre, Constance
    Vray, Muriel
    Lemee, Veronique
    Simon, Francois
    Plantier, Jean-Christophe
    JOURNAL OF CLINICAL VIROLOGY, 2015, 71 : 76 - 81
  • [24] Performance Evaluation of Three Real-Time HIV-1 Viral Load Assays against Amplicor COBAS Monitor v1.5 platform
    McClemon, D.
    Mallan, M.
    Fix, C.
    Hassan, J.
    Conroy, P.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 633 - 634
  • [25] Evaluation of a next-generation Vacutainer® tube for HIV viral load measurements with the Roche COBAS Amplicor HIV-1 Monitor® Assay
    Rainen, L.
    Belem, P.
    Wan, H.
    Dastane, A.
    Brown, M.
    Fernandes, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 645 - 645
  • [26] Evaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma
    Muenchhoff, Maximilian
    Madurai, Savathee
    Hempenstall, Allison Jo
    Adland, Emily
    Carlqvist, Anna
    Moonsamy, Angeline
    Jaggernath, Manjeetha
    Mlotshwa, Busisiwe
    Siboto, Emma
    Ndung'u, Thumbi
    Goulder, Philip Jeremy Renshaw
    PLOS ONE, 2014, 9 (08):
  • [27] Evaluation of the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qualitative version 2 assay on whole blood using specimens with unknown ARV exposure
    Viana, Raquel
    Xaba, Thabisile
    Stojiljkovic, Teja
    Gunther, Nico
    Wallis, Carole
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2015, 18
  • [28] Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays-LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5
    Katsoulidou, A
    Petrodaskalaki, M
    Sypsa, V
    Papachristou, E
    Anastassopoulou, CG
    Gargalianos, P
    Karafoulidou, A
    Lazanas, M
    Kordossis, T
    Andoniadou, A
    Hatzakis, A
    JOURNAL OF VIROLOGICAL METHODS, 2006, 131 (02) : 168 - 174
  • [29] Improving clinical laboratory efficiency: a time-motion evaluation of the Abbott m2000 RealTime and Roche COBAS AmpliPrep/COBAS TaqMan PCR systems for the simultaneous quantitation of HIV-1 RNA and HCV RNA
    Amendola, Alessandra
    Coen, Sabrina
    Belladonna, Stefano
    Pulvirenti, F. Renato
    Clemens, John M.
    Capobianchi, M. Rosaria
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) : 1283 - 1288
  • [30] Improved Performance of COBAS AmpliPrep/COBAS TaqMan Version 2.0 Assay Over Amplicor Monitor Version 1.5 in the Quantification of HIV-1 RNA Viral Load in Abuja, Nigeria
    Abubakar, Ado
    Ndembi, Nicaise
    Ogbanufe, Obinna
    Inalegwu, Auchi
    Wilson, Simi
    Ebagua, Irene
    Peters, Sam
    Chime, Chris
    Dakum, Patrick
    Abimiku, Alash'le G.
    CURRENT HIV RESEARCH, 2015, 13 (04) : 262 - 267