Standard and electrically detected magnetic resonance in nanocrystalline silicon

被引:4
|
作者
Bronner, W
Brüggemann, R
Mehring, M
机构
[1] Univ Stuttgart, Inst Phys 2, D-70569 Stuttgart, Germany
[2] CNRS, Lab Genie Elect Paris, F-91192 Gif Sur Yvette, France
关键词
D O I
10.1016/S0022-3093(99)00844-3
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present results from standard and electrically detected magnetic resonance on nanocrystalline silicon from hot-wire and plasma-enhanced chemical vapour deposition for which the Raman spectra showed the same large crystalline fraction. Based on the fact that dangling bond spin density scales with the sub-band gap absorption coefficient at photon energies < 1.1 eV we suggest the introduction of a calibration factor between the dangling bond spin density and the absorption coefficient. The photocarrier mobility-lifetime product and diffusion length increase with decreasing dangling bond spin density and absorption coefficient. The electrically detected magnetic resonance spectra shows no signal in the dark current and a single line when measured by the spin-dependent photocurrent. The experimentally determined g-value of this line is temperature dependent. The quantum-mechanical spin-pair model explains the electrically detected magnetic resonance signal height. From the spin-pair model we determine microscopic parameters, e.g. singlet-decay rate. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [1] Imaging of electrically detected magnetic resonance of a silicon wafer
    Sato, T
    Yokoyama, H
    Ohya, H
    Kamada, H
    JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (01) : 113 - 116
  • [2] THEORY OF ELECTRICALLY DETECTED MAGNETIC RESONANCE OF TRIPLET CENTERS IN SILICON
    Barabanov, A. V.
    Horoshok, R. A.
    UKRAINIAN JOURNAL OF PHYSICS, 2007, 52 (10): : 973 - 979
  • [3] Electrically detected magnetic resonance
    Fedorych, OM
    Wilamowski, Z
    Jantsch, W
    Sadowski, J
    ACTA PHYSICA POLONICA A, 2004, 105 (06) : 591 - 598
  • [4] Electrically Detected Magnetic Resonance of Donors and Interfacial Defects in Silicon Nanowires
    Fanciulli, M.
    Vellei, A.
    Canevali, C.
    Baldovino, S.
    Pennelli, G.
    Longo, M.
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2011, 3 (04) : 568 - 574
  • [5] The electrically detected magnetic resonance microscope: Combining conductive atomic force microscopy with electrically detected magnetic resonance
    Klein, Konrad
    Hauer, Benedikt
    Stoib, Benedikt
    Trautwein, Markus
    Matich, Sonja
    Huebl, Hans
    Astakhov, Oleksandr
    Finger, Friedhelm
    Bittl, Robert
    Stutzmann, Martin
    Brandt, Martin S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (10):
  • [6] Charge pumping electrically detected magnetic resonance of silicon carbide power transistors
    Lew, C. T. -K.
    Sewani, V. K.
    Ohshima, T.
    McCallum, J. C.
    Johnson, B. C.
    JOURNAL OF APPLIED PHYSICS, 2023, 134 (05)
  • [7] Compact electrically detected magnetic resonance setup
    Eckardt, Michael
    Behrends, Jan
    Muenter, Detlef
    Harneit, Wolfgang
    AIP ADVANCES, 2015, 5 (04):
  • [8] Electrically detected magnetic resonance applied to polyaniline
    Graeff, C.F.O.
    Brunello, C.A.
    Faria, R.M.
    Synthetic Metals, 1999, 101 (01): : 805 - 806
  • [9] Electrically detected magnetic resonance applied to polyaniline
    Graeff, CFO
    Brunello, CA
    Faria, RM
    SYNTHETIC METALS, 1999, 101 (1-3) : 805 - 806
  • [10] Electrically detected magnetic resonance in photoexcited fullerenes
    Eickelkamp, T
    Roth, S
    Mehring, M
    MOLECULAR PHYSICS, 1998, 95 (05) : 967 - 972