Standard and electrically detected magnetic resonance in nanocrystalline silicon

被引:4
|
作者
Bronner, W
Brüggemann, R
Mehring, M
机构
[1] Univ Stuttgart, Inst Phys 2, D-70569 Stuttgart, Germany
[2] CNRS, Lab Genie Elect Paris, F-91192 Gif Sur Yvette, France
关键词
D O I
10.1016/S0022-3093(99)00844-3
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present results from standard and electrically detected magnetic resonance on nanocrystalline silicon from hot-wire and plasma-enhanced chemical vapour deposition for which the Raman spectra showed the same large crystalline fraction. Based on the fact that dangling bond spin density scales with the sub-band gap absorption coefficient at photon energies < 1.1 eV we suggest the introduction of a calibration factor between the dangling bond spin density and the absorption coefficient. The photocarrier mobility-lifetime product and diffusion length increase with decreasing dangling bond spin density and absorption coefficient. The electrically detected magnetic resonance spectra shows no signal in the dark current and a single line when measured by the spin-dependent photocurrent. The experimentally determined g-value of this line is temperature dependent. The quantum-mechanical spin-pair model explains the electrically detected magnetic resonance signal height. From the spin-pair model we determine microscopic parameters, e.g. singlet-decay rate. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [21] Electrically Detected Magnetic Resonance on a Chip (EDMRoC) for Analysis of Thin-Film Silicon Photovoltaics
    Segantini, Michele
    Marcozzi, Gianluca
    Djekic, Denis
    Chu, Anh
    Amkreutz, Daniel
    Trinh, Cham Thi
    Neubert, Sebastian
    Stannowski, Bernd
    Jacob, Kerstin
    Rudolph, Ivo
    McPeak, Joseph E.
    Anders, Jens
    Naydenov, Boris
    Lips, Klaus
    MAGNETOCHEMISTRY, 2023, 9 (07)
  • [22] Linewidth of Low-Field Electrically Detected Magnetic Resonance of Phosphorus in Isotopically Controlled Silicon
    Morishita, Hiroki
    Abe, Eisuke
    Akhtar, Waseem
    Vlasenko, Leonid S.
    Fujimoto, Akira
    Sawano, Kentarou
    Shiraki, Yasuhiro
    Dreher, Lukas
    Riemann, Helge
    Abrosimov, Nikolai V.
    Becker, Peter
    Pohl, Hans-J.
    Thewalt, Mike L. W.
    Brandt, Martin S.
    Itoh, Kohei M.
    APPLIED PHYSICS EXPRESS, 2011, 4 (02)
  • [23] TEMPERATURE-DEPENDENT ELECTRICALLY DETECTED MAGNETIC-RESONANCE STUDIES ON SILICON PN DIODES
    CHRISTMANN, P
    STADLER, W
    MEYER, BK
    APPLIED PHYSICS LETTERS, 1995, 66 (12) : 1521 - 1523
  • [24] Broadband electrically detected magnetic resonance of phosphorus donors in a silicon field-effect transistor
    van Beveren, L. H. Willems
    Huebl, H.
    McCamey, D. R.
    Duty, T.
    Ferguson, A. J.
    Clark, R. G.
    Brandt, M. S.
    APPLIED PHYSICS LETTERS, 2008, 93 (07)
  • [25] Electrically detected magnetic resonance at different microwave frequencies
    Brandt, MS
    Bayerl, MW
    Reinacher, NM
    Wimbauer, T
    Stutzmann, M
    DEFECTS IN SEMICONDUCTORS - ICDS-19, PTS 1-3, 1997, 258-2 : 963 - 968
  • [26] Pulsed electrically detected magnetic resonance in organic semiconductors
    Boehme, C.
    McCamey, D. R.
    van Schooten, K. J.
    Baker, W. J.
    Lee, S. -Y.
    Paik, S. -Y.
    Lupton, J. M.
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2009, 246 (11-12): : 2750 - 2755
  • [27] Electrically detected magnetic resonance on GaAs/AlGaAs heterostructures
    Wimbauer, T
    Hofmann, DM
    Meyer, BK
    Brandt, MS
    Brandl, T
    Bayerl, MW
    Reinacher, NM
    Stutzmann, M
    Mochizuki, Y
    Mizuta, M
    DEFECTS IN ELECTRONIC MATERIALS II, 1997, 442 : 511 - 516
  • [28] Electrically detected magnetic resonance in undoped polyacetylene and polyaniline
    Technische Universitaet Muenchen, Garching, Germany
    Phys Status Solidi A, 2 (713-721):
  • [29] Electrically detected magnetic resonance in undoped polyacetylene and polyaniline
    Graeff, CFO
    Brandt, MS
    Faria, RM
    Leising, G
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1997, 162 (02): : 713 - 721
  • [30] Wafer-Level Electrically Detected Magnetic Resonance: Magnetic Resonance in a Probing Station
    McCrory, Duane J.
    Anders, Mark A.
    Ryan, Jason T.
    Shrestha, Pragya R.
    Cheung, Kin P.
    Lenahan, Patrick M.
    Campbell, Jason P.
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2018, 18 (02) : 139 - 143