Standard and electrically detected magnetic resonance in nanocrystalline silicon

被引:4
|
作者
Bronner, W
Brüggemann, R
Mehring, M
机构
[1] Univ Stuttgart, Inst Phys 2, D-70569 Stuttgart, Germany
[2] CNRS, Lab Genie Elect Paris, F-91192 Gif Sur Yvette, France
关键词
D O I
10.1016/S0022-3093(99)00844-3
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present results from standard and electrically detected magnetic resonance on nanocrystalline silicon from hot-wire and plasma-enhanced chemical vapour deposition for which the Raman spectra showed the same large crystalline fraction. Based on the fact that dangling bond spin density scales with the sub-band gap absorption coefficient at photon energies < 1.1 eV we suggest the introduction of a calibration factor between the dangling bond spin density and the absorption coefficient. The photocarrier mobility-lifetime product and diffusion length increase with decreasing dangling bond spin density and absorption coefficient. The electrically detected magnetic resonance spectra shows no signal in the dark current and a single line when measured by the spin-dependent photocurrent. The experimentally determined g-value of this line is temperature dependent. The quantum-mechanical spin-pair model explains the electrically detected magnetic resonance signal height. From the spin-pair model we determine microscopic parameters, e.g. singlet-decay rate. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [31] Electrically detected magnetic resonance of phosphorous due to spin dependent recombination with triplet centers in γ-irradiated silicon
    Akhtar, W.
    Morishita, H.
    Vlasenko, L. S.
    Poloskin, D. S.
    Itoh, K. M.
    PHYSICA B-CONDENSED MATTER, 2009, 404 (23-24) : 4583 - 4585
  • [32] Identification of transport and recombination paths in homo and heterojunction silicon solar cells by electrically detected magnetic resonance
    Müller, R
    Kanschat, P
    von Aichberger, S
    Lips, K
    Fuhs, W
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2000, 266 : 1124 - 1128
  • [33] Quanitative Electrically Detected Magnetic Resonance for Device Reliability Studies
    Cochrane, Corey J.
    Anders, Mark
    Mutch, Mike
    Lenahan, Patrick
    2014 IEEE INTERNATIONAL INTEGRATED RELIABILITY WORKSHOP FINAL REPORT (IIRW), 2014, : 6 - 9
  • [34] Lock-in detection for pulsed electrically detected magnetic resonance
    Hoehne, Felix
    Dreher, Lukas
    Behrends, Jan
    Fehr, Matthias
    Huebl, Hans
    Lips, Klaus
    Schnegg, Alexander
    Suckert, Max
    Stutzmann, Martin
    Brandt, Martin S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04):
  • [35] Pulsed low-field electrically detected magnetic resonance
    Dreher, L.
    Hoehne, F.
    Morishita, H.
    Huebl, H.
    Stutzmann, M.
    Itoh, K. M.
    Brandt, M. S.
    PHYSICAL REVIEW B, 2015, 91 (07):
  • [36] Broadband electrically detected magnetic resonance using adiabatic pulses
    Hrubesch, F. M.
    Braunbeck, G.
    Voss, A.
    Stutzmann, M.
    Brandt, M. S.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 254 : 62 - 69
  • [37] Electrically detected magnetic resonance studies of phosphorus doped diamond
    Graf, T
    Brandt, MS
    Nebel, CE
    Stutzmann, M
    Koizumi, S
    PHYSICA B-CONDENSED MATTER, 2001, 308 : 593 - 597
  • [38] Aging effects in polyaniline studied by electrically detected magnetic resonance
    Graeff, CFO
    Brunello, CA
    SYNTHETIC METALS, 2001, 119 (1-3) : 327 - 328
  • [39] Electrically detected magnetic resonance of organic Schottky barrier diodes
    Masuno, Yukari
    Kitami, Yusuke
    Fukuda, Kunito
    Kanki, Teruo
    Tanaka, Hidekazu
    Asakawa, Naoki
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2020, 704 (01) : 17 - 23
  • [40] Electrically detected magnetic resonance of MEH-PPV diodes
    Silva, GB
    Santos, LF
    Faria, RM
    Graeff, CFO
    ORGANIC AND POLYMERIC MATERIALS AND DEVICES-OPTICAL, ELECTRICAL AND OPTOELECTRONIC PROPERTIES, 2002, 725 : 105 - 110