A Practical, Automated Quality Assurance Method for Measuring Spatial Resolution in PET

被引:29
|
作者
Lodge, Martin A. [1 ]
Rahmim, Arman [1 ]
Wahl, Richard L. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Nucl Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr Johns Hopkins, Baltimore, MD USA
关键词
spatial resolution; quality assurance; multicenter trials; PET; IMAGE-RECONSTRUCTION; EMISSION-TOMOGRAPHY; PERFORMANCE;
D O I
10.2967/jnumed.108.060079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of different scanners, acquisition protocols, and reconstruction algorithms has been identified as a problem that limits the use of PET in multicenter trials. The aim of this project was to aid standardization of data collection by developing a quality assurance method for measuring the spatial resolution achieved with clinical imaging protocols. Methods: A commercially available 68Ge cylinder phantom (diameter, 20 cm) with a uniform activity concentration was positioned in the center of the PET field of view, and an image was acquired using typical clinical parameters. Spatial resolution was measured by artificially generating an object function (O) with uniform activity within a 20-cm-diameter cylinder, assuming no noise and perfect spatial resolution, centered on the original image (I); dividing F[I] by F[O], where F indicates a 2-dimensional Fourier transform, to produce a modulation transfer function; and taking the inverse Fourier transform of the modulation transfer function to produce a point-spread function in image space. The method was validated using data acquired on 4 different commercial PET systems. Results: Spatial resolution on the Discovery LS was measured at 5.75 +/- 0.58 mm, compared with 5.54 +/- 0.19 mm from separate point source measurements. Variability of the resolution measurements differed between scanners and protocols, but the typical SD was approximately 0.15 mm when iterative reconstruction was used. The potential for predicting resolution recovery coefficients for small objects was also demonstrated. Conclusion: The proposed method does not require elaborate phantom preparation and is practical to perform, and data analysis is fully automated. This approach is useful for evaluating clinical reconstruction protocols across varying scanners and reconstruction algorithms and should greatly aid standardization of data collection between centers.
引用
收藏
页码:1307 / 1314
页数:8
相关论文
共 50 条
  • [41] Practical Suggestions for Annual Quality Assurance in CyberKnife
    Prabhu, A.
    Saini, D.
    Patadiya, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] A practical approach to quality assurance in critical systems
    Moura, CAT
    Lahoz, CHN
    Abdala, MAD
    DEPENDABLE COMPUTING, 2003, 2847 : 369 - 370
  • [43] Quality Assurance in Immunocytochemistry: A Review and Practical Considerations
    Lozano, Maria D.
    Robledano, Ramon
    Argueta, Allan
    ACTA CYTOLOGICA, 2024,
  • [44] QUALITY ASSURANCE IN PROJECT MANAGEMENT -PRACTICAL EXPERIENCE
    Rakovic, Radoslav
    16TH ISSAT INTERNATIONAL CONFERENCE ON RELIABILITY AND QUALITY IN DESIGN, 2010, : 372 - 376
  • [45] QUALITY ASSURANCE IN GYNECOLOGIC CYTOLOGY - WHAT IS PRACTICAL
    ROHR, LR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1990, 94 (06) : 754 - 758
  • [46] QUALITY ASSURANCE - OPPORTUNITY FOR PRACTICAL STUDENT EXPERIENCE
    BRAYMAN, SJ
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1992, 46 (04): : 369 - 371
  • [47] Robust automated quality assurance of radiosonde temperatures
    Durre, Imke
    Vose, Russell S.
    Wuertz, David B.
    JOURNAL OF APPLIED METEOROLOGY AND CLIMATOLOGY, 2008, 47 (08) : 2081 - 2095
  • [48] PET IMAGE QUALITY ASSURANCE WITH MADEIRA PHANTOM
    Chipiga, Larisa
    Zvonova, Irina
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 111 - 114
  • [49] MEDIAN POLISH FOR QUALITY ASSURANCE OF A PET SCANNER
    KEARFOTT, KJ
    RUCKER, RH
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (05) : 932 - 939
  • [50] Automated Quality Assurance for XML Controlled Linacs
    Valdes, G.
    Morin, O.
    Pouliot, J.
    Chuang, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 232 - 232