Propofol/Remifentanil Anesthesia Might Not Alter the Middle Cerebral Artery Diameter by Digital Subtraction Angiography

被引:2
|
作者
Arrigoni-Marocco, Stefano [1 ]
Engrand, Nicolas [3 ]
Civelli, Vittorio [4 ]
Mateo, Joaquim [1 ,2 ]
Labeyrie, Marc-Antoine [4 ]
Saint-Maurice, Jean-Pierre [4 ]
Mebazaa, Alexandre [1 ,2 ,5 ]
Gayat, Etienne [1 ,2 ,5 ]
Houdart, Emmanuel [2 ,4 ]
Vallee, Fabrice [1 ,2 ,5 ,6 ]
机构
[1] Hop Univ St Louis Lariboisiere, AP HP, Crit Care & Burn Unit, Dept Anesthesia, 2 Rue Ambroise Pare, F-75010 Paris, France
[2] Paris Diderot Univ, Paris, France
[3] Fdn Adolphe De Rothschild, Anaesthesia & Intens Care Div, 25 Rue Manin, F-75019 Paris, France
[4] Hop Univ St Louis Lariboisiere, AP HP, Intervent Neuroradiol Unit, 2 Rue Ambroise Pare, F-75010 Paris, France
[5] INSERM, UMR S 942, Paris, France
[6] Univ Paris Saclay, Ecole Polytech, LMS, M3DISIM,Inria,CNRS, St Aubin, France
关键词
Cerebral blood flow; Digital subtraction angiography; Middle cerebral artery; General anesthesia; Transcranial Doppler; TRANSCRANIAL DOPPLER SONOGRAPHY; FLOW VELOCITY; BLOOD-FLOW; SUBARACHNOID HEMORRHAGE; PROPOFOL ANESTHESIA; GENERAL-ANESTHESIA; CARBON-DIOXIDE; REMIFENTANIL; AUTOREGULATION; METABOLISM;
D O I
10.1007/s12028-019-00699-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Transcranial Doppler (TCD) of the middle cerebral artery (MCA) enables the measurement of the mean blood velocity (MCA(Vm)) and the estimation of the cerebral blood flow (CBF), provided that no significant changes occur in the MCA diameter (MCA(Diam)). Previous studies described a decrease in the MCA(Vm) associated with the induction of total intravenous anesthesia (TIVA) by propofol and remifentanil. This decrease in blood velocity might be interpreted as a decrease in the CBF only where the MCA(Diam) is not modified across TCD examinations. Methods In this observational study, we measured the MCA(Diam) of 24 subjects (almost exclusively females) on digital subtraction angiography under awake and TIVA conditions. Results Across the two phases, we observed a decrease in the mean arterial blood pressure (from 84 +/- 9 to 71 +/- 6 mmHg; p < 0.001) and heart rate (76 +/- 10 vs. 65 +/- 8 beats/min; p < 0.001), and a concomitant decrease in the MCA(Vm) (61 vs. 42 cm/s; p < 0.001). In contrast, the MCA(Diam) did not vary in association with TIVA (2.3 +/- 0.2 vs. 2.3 +/- 0.2 mm; p = 0.52). Conclusions Those results suggested that in this population, no significant changes in the MCA(Diam) are associated with TIVA.
引用
收藏
页码:338 / 345
页数:8
相关论文
共 50 条
  • [21] Automated image registration of cerebral digital subtraction angiography
    Hellebrekers, Vincent J. W.
    van Walsum, Theo
    Smal, Ihor
    Cornelissen, Sandra A. P.
    van Zwam, Wim H.
    Van der Lugt, Aad
    Van der Sluijs, Matthijs
    Su, Ruisheng
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (01) : 147 - 150
  • [22] Digital Subtraction Angiography of Cerebral Vessels: Basic Technique
    Singh, Deepak K.
    Yadav, Kuldeep
    Singh, Arun K.
    Sinha, Kshitij
    Kaif, Mohd
    Kumar, Rakesh
    Chand, Vipin K.
    NEUROLOGY INDIA, 2023, 71 (01) : 31 - 34
  • [23] Cerebral Blood Flow Assessment by Digital Subtraction Angiography
    Hsu, C. -Y.
    Alaraj, A.
    Linninger, A. A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 43 - 43
  • [24] Evaluation of relation among aneurysmal neck, parent artery, and daughter arteries in middle cerebral artery aneurysms, by three-dimensional digital subtraction angiography
    Sadatomo, T
    Yuki, K
    Migita, K
    Taniguchi, E
    Kodama, Y
    Kurisu, K
    NEUROSURGICAL REVIEW, 2005, 28 (03) : 196 - 200
  • [25] Evaluation of relation among aneurysmal neck, parent artery, and daughter arteries in middle cerebral artery aneurysms, by three-dimensional digital subtraction angiography
    Takashi Sadatomo
    Kiyoshi Yuki
    Keisuke Migita
    Eiji Taniguchi
    Yasunori Kodama
    Kaoru Kurisu
    Neurosurgical Review, 2005, 28 : 196 - 200
  • [26] MR digital subtraction angiography of cerebral arteriovenous malformations
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (04) : 707 - 711
  • [27] DIGITAL VIDEO SUBTRACTION ANGIOGRAPHY OF THE CERVICAL AND CEREBRAL VASCULATURE
    SEEGER, JF
    WEINSTEIN, PR
    CARMODY, RF
    OVITT, TW
    FISHER, HD
    CAPP, MP
    JOURNAL OF NEUROSURGERY, 1982, 56 (02) : 173 - 179
  • [28] Automated image registration of cerebral digital subtraction angiography
    Vincent J. W. Hellebrekers
    Theo van Walsum
    Ihor Smal
    Sandra A. P. Cornelissen
    Wim H. van Zwam
    Aad van der Lugt
    Matthijs van der Sluijs
    Ruisheng Su
    International Journal of Computer Assisted Radiology and Surgery, 2024, 19 : 147 - 150
  • [29] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF THE EXTRACRANIAL CEREBRAL VESSELS
    PORTE, ME
    MCIVOR, J
    CLINICAL RADIOLOGY, 1992, 46 (03) : 218 - 218
  • [30] Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study
    Halama, Dirk
    Merkel, Helena
    Werdehausen, Robert
    Gaber, Khaled
    Schob, Stefan
    Quaschling, Ulf
    Ziganshyna, Svitlana
    Hoffmann, Karl-Titus
    Lindner, Dirk
    Richter, Cindy
    DIAGNOSTICS, 2022, 12 (10)