Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study

被引:4
|
作者
Halama, Dirk [1 ]
Merkel, Helena [2 ]
Werdehausen, Robert [3 ]
Gaber, Khaled [4 ]
Schob, Stefan [5 ]
Quaschling, Ulf [6 ]
Ziganshyna, Svitlana [7 ]
Hoffmann, Karl-Titus [1 ]
Lindner, Dirk [4 ]
Richter, Cindy [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Oral & Maxillofacial Surg, D-04103 Leipzig, Germany
[2] Univ Leipzig, Med Ctr, Dept Neuroradiol, D-04103 Leipzig, Germany
[3] Univ Leipzig, Med Ctr, Dept Anesthesiol & Intens Care Med, D-04103 Leipzig, Germany
[4] Univ Leipzig, Med Ctr, Dept Neurosurg, D-04103 Leipzig, Germany
[5] Halle Univ Hosp, Dept Radiol, D-06120 Halle, Germany
[6] Kantonsspital Baselland, Dept Radiol, CH-4410 Liestal, Switzerland
[7] Univ Leipzig, Med Ctr, Transplant Coordinator Unit, D-04103 Leipzig, Germany
关键词
vessel diameter; reference value; effect size; nomogram; morphological variation; digital subtraction angiography; ANEURYSMAL SUBARACHNOID HEMORRHAGE; ADULT LIFE; BLOOD-FLOW; VASOSPASM; WILLIS; CIRCLE; SEX; AGE; EPIDEMIOLOGY; BIFURCATION;
D O I
10.3390/diagnostics12102471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A threshold-based classification of cerebral vasospasm needs reference values for intracranial vessel diameters on digital subtraction angiography (DSA). We aimed to generate adjusted reference values for this purpose by retrospectively analyzing angiograms and potential influencing factors on vessel diameters. Angiograms of the anterior circulation were evaluated in 278 patients aged 18-81 years. The vessel diameters of 453 angiograms (175 bilateral) were gathered from nine defined measuring sites. The effect sizes of physical characteristics (i.e., body weight and height, body mass index, gender, age, and cranial side) and anatomical variations were calculated with MANOVA. Segments bearing aneurysms were excluded for the calculation of reference values. Adjusted vessel diameters were calculated via linear regression analysis of the vessel diameter data. Vessel diameters increased with age and body height. Male and right-sided vessels were larger in diameter. Of the anatomical variations, only the hypoplastic/aplastic A1 segment had a significant influence (p < 0.05) on values of the anterior cerebral artery and the internal carotid artery with a small effect size (|omega(2)| > 0.01) being excluded from the reference values. We provide gender-, age-, and side-adjusted reference values and nomograms of arterial vessel diameters in the anterior circulation.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] MEASUREMENT OF ABSOLUTE CORONARY-ARTERY DIAMETERS BY DIGITAL SUBTRACTION ANGIOGRAPHY
    ROSENBERG, MC
    KLEIN, LW
    AGARWAL, JB
    STETS, G
    WEINTRAUB, WS
    HELFANT, RH
    CLINICAL RESEARCH, 1987, 35 (03): : A321 - A321
  • [2] Middle rectal artery: myth or reality? Retrospective study with CT angiography and digital subtraction angiography
    Bilhim, Tiago
    Pereira, Jose A.
    Tinto, Hugo Rio
    Fernandes, Lucia
    Duarte, Marisa
    O'Neill, Joao E.
    Pisco, Joao M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2013, 35 (06) : 517 - 522
  • [3] Middle rectal artery: myth or reality? Retrospective study with CT angiography and digital subtraction angiography
    Tiago Bilhim
    José A. Pereira
    Hugo Rio Tinto
    Lúcia Fernandes
    Marisa Duarte
    João E. O’Neill
    João M. Pisco
    Surgical and Radiologic Anatomy, 2013, 35 : 517 - 522
  • [4] MR angiography of the great anterior radiculomedullary artery (Adamkiewicz artery) validated by digital subtraction angiography
    Nijenhuis, R. J.
    Mull, M.
    Wilmink, J. T.
    Thron, A. K.
    Backes, W. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (07) : 1565 - 1572
  • [5] Identification of the ascending middle cerebral artery branches on digital subtraction angiography
    Christoforidis, GA
    Kollias, SS
    Valavanis, A
    NEURORADIOLOGY, 2002, 44 (10) : 803 - 805
  • [6] Identification of the ascending middle cerebral artery branches on digital subtraction angiography
    G. Christoforidis
    S. Kollias
    A. Valavanis
    Neuroradiology, 2002, 44 : 803 - 805
  • [7] CAVE: Cerebral artery-vein segmentation in digital subtraction angiography
    Su, Ruisheng
    van der Sluijs, P. Matthijs
    Chen, Yuan
    Cornelissen, Sandra
    van den Broek, Ruben
    van Zwam, Wim H.
    van der Lugt, Aad
    Niessen, Wiro J.
    Ruijters, Danny
    van Walsum, Theo
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2024, 115
  • [8] Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: Injection method and optimization
    Tu, RK
    Cohen, WA
    Maravilla, KR
    Bush, WH
    Patel, NH
    Eskridge, J
    Winn, HR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (06) : 1127 - 1136
  • [9] Reevaluating the Transcranial Doppler Criteria for Estimation of Anterior Circulation Artery Stenosis Transcranial Doppler Sonography Versus Digital Subtraction Angiography
    Fu, Xian
    Yin, Jianrui
    Wong, Ka Sing
    Gao, Cong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (08) : 1187 - 1191
  • [10] Three dimensional digital subtraction angiography imaging of a ruptured aneurysm on the anterior communicating artery
    Kojima, A
    Yamaguchi, N
    Okui, S
    SURGICAL NEUROLOGY, 2002, 58 (01): : 49 - 53