Propofol/Remifentanil Anesthesia Might Not Alter the Middle Cerebral Artery Diameter by Digital Subtraction Angiography

被引:2
|
作者
Arrigoni-Marocco, Stefano [1 ]
Engrand, Nicolas [3 ]
Civelli, Vittorio [4 ]
Mateo, Joaquim [1 ,2 ]
Labeyrie, Marc-Antoine [4 ]
Saint-Maurice, Jean-Pierre [4 ]
Mebazaa, Alexandre [1 ,2 ,5 ]
Gayat, Etienne [1 ,2 ,5 ]
Houdart, Emmanuel [2 ,4 ]
Vallee, Fabrice [1 ,2 ,5 ,6 ]
机构
[1] Hop Univ St Louis Lariboisiere, AP HP, Crit Care & Burn Unit, Dept Anesthesia, 2 Rue Ambroise Pare, F-75010 Paris, France
[2] Paris Diderot Univ, Paris, France
[3] Fdn Adolphe De Rothschild, Anaesthesia & Intens Care Div, 25 Rue Manin, F-75019 Paris, France
[4] Hop Univ St Louis Lariboisiere, AP HP, Intervent Neuroradiol Unit, 2 Rue Ambroise Pare, F-75010 Paris, France
[5] INSERM, UMR S 942, Paris, France
[6] Univ Paris Saclay, Ecole Polytech, LMS, M3DISIM,Inria,CNRS, St Aubin, France
关键词
Cerebral blood flow; Digital subtraction angiography; Middle cerebral artery; General anesthesia; Transcranial Doppler; TRANSCRANIAL DOPPLER SONOGRAPHY; FLOW VELOCITY; BLOOD-FLOW; SUBARACHNOID HEMORRHAGE; PROPOFOL ANESTHESIA; GENERAL-ANESTHESIA; CARBON-DIOXIDE; REMIFENTANIL; AUTOREGULATION; METABOLISM;
D O I
10.1007/s12028-019-00699-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Transcranial Doppler (TCD) of the middle cerebral artery (MCA) enables the measurement of the mean blood velocity (MCA(Vm)) and the estimation of the cerebral blood flow (CBF), provided that no significant changes occur in the MCA diameter (MCA(Diam)). Previous studies described a decrease in the MCA(Vm) associated with the induction of total intravenous anesthesia (TIVA) by propofol and remifentanil. This decrease in blood velocity might be interpreted as a decrease in the CBF only where the MCA(Diam) is not modified across TCD examinations. Methods In this observational study, we measured the MCA(Diam) of 24 subjects (almost exclusively females) on digital subtraction angiography under awake and TIVA conditions. Results Across the two phases, we observed a decrease in the mean arterial blood pressure (from 84 +/- 9 to 71 +/- 6 mmHg; p < 0.001) and heart rate (76 +/- 10 vs. 65 +/- 8 beats/min; p < 0.001), and a concomitant decrease in the MCA(Vm) (61 vs. 42 cm/s; p < 0.001). In contrast, the MCA(Diam) did not vary in association with TIVA (2.3 +/- 0.2 vs. 2.3 +/- 0.2 mm; p = 0.52). Conclusions Those results suggested that in this population, no significant changes in the MCA(Diam) are associated with TIVA.
引用
收藏
页码:338 / 345
页数:8
相关论文
共 50 条
  • [31] Digital subtraction angiography of a persistent trigeminal artery variant
    Temizoz, Osman
    Genchellac, Hakan
    Unlu, Ercuement
    Cagli, Bekir
    Ozdemir, Hueseyin
    Demir, M. Kemal
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2010, 16 (03) : 245 - 247
  • [32] Remifentanil-clonidine-propofol versus sufentanil-propofol anesthesia for coronary artery bypass surgery
    Gerlach, K
    Uhlig, T
    Hüppe, M
    Kraatz, E
    Saager, L
    Schmitz, A
    Dörges, V
    Schmucker, P
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (06) : 703 - 708
  • [33] DIGITAL SUBTRACTION CEREBRAL-ANGIOGRAPHY BY INTRAARTERIAL INJECTION - COMPARISON WITH CONVENTIONAL ANGIOGRAPHY
    BRANTZAWADZKI, M
    GOULD, R
    NORMAN, D
    NEWTON, TH
    LANE, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) : 347 - 353
  • [34] Evaluating the length, diameter, and stenosis of deep circumflex iliac artery and neighboring arteries based on digital subtraction angiography
    Schulte, Raimund
    Loberg, Christina
    Ghassemi, Alireza
    MICROSURGERY, 2023, 43 (04) : 373 - 381
  • [35] MR angiography of the great anterior radiculomedullary artery (Adamkiewicz artery) validated by digital subtraction angiography
    Nijenhuis, R. J.
    Mull, M.
    Wilmink, J. T.
    Thron, A. K.
    Backes, W. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (07) : 1565 - 1572
  • [36] Color-Coded Digital Subtraction Angiography in the Management of a Rare Case of Middle Cerebral Artery Pure Arterial Malformation A Technical and Case Report
    Feliciano, Caleb E.
    Pamias-Portalatin, Eva
    Mendoza-Torres, Jorge
    Effio, Euclides
    Moran, Yadira
    Rodriguez-Mercado, Rafael
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (06) : 715 - 721
  • [37] Utility of Screening for Cerebral Vasospasm Using Digital Subtraction Angiography
    Arias, Eric J.
    Vajapey, Sravya
    Reynolds, Matthew R.
    Chicoine, Michael R.
    Rich, Keith M.
    Dacey, Ralph G., Jr.
    Dorward, Ian G.
    Derdeyn, Colin P.
    Moran, Christopher J.
    Cross, DeWitte T., III
    Zipfel, Gregory J.
    Dhar, Rajat
    STROKE, 2015, 46 (11) : 3137 - 3141
  • [38] Cerebral Hemorrhage Identifying the Causes during digital Subtraction Angiography
    Meinrenken, Susanne
    FORTSCHRITTE DER NEUROLOGIE PSYCHIATRIE, 2016, 84 (02) : 64 - 64
  • [39] Safety of cerebral digital subtraction angiography : complication rate analysis
    Usman, Fritz Sumantri
    Sani, Achmad Firdaus
    Husain, Shakir
    UNIVERSA MEDICINA, 2012, 31 (01) : 27 - 33
  • [40] IODIXANOL IN INTRAARTERIAL CEREBRAL DIGITAL SUBTRACTION ANGIOGRAPHY - A COMPARISON WITH IOHEXOL
    KENDALL, BE
    SHEPPICK, A
    NOSSEN, JO
    STEVENS, JM
    NEURORADIOLOGY, 1995, 37 (07) : 512 - 514