Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy

被引:185
|
作者
Taddei, Fulvia [1 ]
Cristofolini, Luca
Martelli, Saulo
Gill, H. S.
Viceconti, Marco
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[2] Univ Bologna, Fac Engn, DIEM, Bologna, Italy
[3] Univ Oxford, Nuffield Dept Orthopaed Surg, OOEC, Oxford, England
关键词
finite element modelling; automatic mesh generation; computed tomography; experimental validation; human bones;
D O I
10.1016/j.jbiomech.2005.07.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of the mechanical stresses induced in human bones is of great importance in both research and clinical practice. Since the stresses in bones cannot be measured non-invasively in vivo, the only way to estimate them is through subject-specific finite element modelling. Several methods exist for the automatic generation of these models from CT data, but before bringing them in the clinical practice it is necessary to assess their accuracy in the predictions of the bone stresses. Particular attention should be paid to those regions, like the epiphyseal and metaphyseal parts of long bones, where the automatic methods are typically less accurate. Aim of the present study was to implement a general procedure to automatically generate subject-specific finite element models of bones from CT data and estimate the accuracy of this general procedure by applying it to one real femur. This femur was tested in vitro under five different loading scenarios and the results of these tests were used to verify how the adoption of a simplified two-material homogeneous model would change the accuracy with respect to the density-based inhomogeneous one, with special attention paid to the epiphyseal and metaphyseal proximal regions of the bone. The results showed that the density-based inhomogeneous model predicts with a very good accuracy the measured stresses (R(2) = 0.91, RMSE = 8.6%, peak error = 27%), while the two-material model was less accurate (R(2) = 0.89, RMSE = 9.6%, peak error = 35%). The results showed that it is possible to automatically generate accurate finite element models of bones from CT data and that the strategy of material properties mapping has a significant influence on its accuracy. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2457 / 2467
页数:11
相关论文
共 50 条
  • [41] Toward subject-specific evaluation: methods of evaluating finite element brain models using experimental high-rate rotational brain motion
    Ahmed Alshareef
    Taotao Wu
    J. Sebastian Giudice
    Matthew B. Panzer
    Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2301 - 2317
  • [42] ARE MRIs NECESSARY TO DEVELOP SUBJECT-SPECIFIC CARTILAGE AND MENISCI GEOMETRIES FOR SUBJECT-SPECIFIC KNEE MODELS?
    Pianigiani, Silvia
    D'Aiuto, Marta
    Croce, Davide
    Innocenti, Bernardo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [43] Toward subject-specific evaluation: methods of evaluating finite element brain models using experimental high-rate rotational brain motion
    Alshareef, Ahmed
    Wu, Taotao
    Giudice, J. Sebastian
    Panzer, Matthew B.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (06) : 2301 - 2317
  • [44] Expediting Finite Element Analyses for Subject-Specific Studies of Knee Osteoarthritis: A Literature Review
    Paz, Alexander
    Orozco, Gustavo A.
    Korhonen, Rami K.
    Garcia, Jose J.
    Mononen, Mika E.
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [45] Sensitivity analysis of a validated subject-specific finite element model of the human craniofacial skeleton
    Szwedowski, T. D.
    Fialkov, J.
    Whyne, C. M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H1) : 58 - 67
  • [46] Maximum principal strain as a criterion for prediction of orthodontic mini-implants failure in subject-specific finite element models
    Albogha, Mhd Hassan
    Kitahara, Toru
    Todo, Mitsugu
    Hyakutake, Hiroto
    Takahashi, Ichiro
    ANGLE ORTHODONTIST, 2016, 86 (01) : 24 - 31
  • [47] Subject-Specific Finite Element Models of the Tibia With Realistic Boundary Conditions Predict Bending Deformations Consistent With In Vivo Measurement
    Haider, Ifaz T.
    Baggaley, Michael
    Edwards, W. Brent
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (02):
  • [48] Explicit Finite Element Models Accurately Predict Subject-Specific and Velocity-Dependent Kinetics of Sideways Fall Impact
    Fleps, Ingmar
    Guy, Pierre
    Ferguson, Stephen J.
    Cripton, Peter A.
    Helgason, Benedikt
    JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 (10) : 1837 - 1850
  • [49] Subject-specific finite element analysis of a lumbar cage produced by electron beam melting
    Epasto, Gabriella
    Distefano, Fabio
    Mineo, Rosalia
    Guglielmino, Eugenio
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (12) : 2771 - 2781
  • [50] Atlas-Based Automatic Generation of Subject-Specific Finite Element Tongue Meshes
    Ahmad Bijar
    Pierre-Yves Rohan
    Pascal Perrier
    Yohan Payan
    Annals of Biomedical Engineering, 2016, 44 : 16 - 34