Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy

被引:185
|
作者
Taddei, Fulvia [1 ]
Cristofolini, Luca
Martelli, Saulo
Gill, H. S.
Viceconti, Marco
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[2] Univ Bologna, Fac Engn, DIEM, Bologna, Italy
[3] Univ Oxford, Nuffield Dept Orthopaed Surg, OOEC, Oxford, England
关键词
finite element modelling; automatic mesh generation; computed tomography; experimental validation; human bones;
D O I
10.1016/j.jbiomech.2005.07.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of the mechanical stresses induced in human bones is of great importance in both research and clinical practice. Since the stresses in bones cannot be measured non-invasively in vivo, the only way to estimate them is through subject-specific finite element modelling. Several methods exist for the automatic generation of these models from CT data, but before bringing them in the clinical practice it is necessary to assess their accuracy in the predictions of the bone stresses. Particular attention should be paid to those regions, like the epiphyseal and metaphyseal parts of long bones, where the automatic methods are typically less accurate. Aim of the present study was to implement a general procedure to automatically generate subject-specific finite element models of bones from CT data and estimate the accuracy of this general procedure by applying it to one real femur. This femur was tested in vitro under five different loading scenarios and the results of these tests were used to verify how the adoption of a simplified two-material homogeneous model would change the accuracy with respect to the density-based inhomogeneous one, with special attention paid to the epiphyseal and metaphyseal proximal regions of the bone. The results showed that the density-based inhomogeneous model predicts with a very good accuracy the measured stresses (R(2) = 0.91, RMSE = 8.6%, peak error = 27%), while the two-material model was less accurate (R(2) = 0.89, RMSE = 9.6%, peak error = 35%). The results showed that it is possible to automatically generate accurate finite element models of bones from CT data and that the strategy of material properties mapping has a significant influence on its accuracy. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2457 / 2467
页数:11
相关论文
共 50 条
  • [21] Investigating the Effect of Brain Size on Deformation Magnitude Using Subject-Specific Finite Element Models
    Giudice, J. Sebastian
    Druzgal, T. Jason
    Panzer, Matthew B.
    JOURNAL OF NEUROTRAUMA, 2023, 40 (15-16) : 1796 - 1807
  • [22] Automatic generation of subject-specific finite element models of the spine from magnetic resonance images
    Kok, Joeri
    Shcherbakova, Yulia M.
    Schlosser, Tom P. C.
    Seevinck, Peter R.
    van der Velden, Tijl A.
    Castelein, Rene M.
    Ito, Keita
    van Rietbergen, Bert
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [23] In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area
    Kyoung-Tak Kang
    Sung-Hwan Kim
    Juhyun Son
    Young Han Lee
    Heoung-Jae Chun
    International Journal of Precision Engineering and Manufacturing, 2015, 16 : 1171 - 1177
  • [24] Predicting the subject-specific primary stability of cementless implants during pre-operative planning: Preliminary validation of subject-specific finite-element models
    Reggiani, B.
    Cristofolini, L.
    Varini, E.
    Viceconti, M.
    JOURNAL OF BIOMECHANICS, 2007, 40 (11) : 2552 - 2558
  • [25] In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area
    Kang, Kyoung-Tak
    Kim, Sung-Hwan
    Son, Juhyun
    Lee, Young Han
    Chun, Heoung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (06) : 1171 - 1177
  • [26] Development and validation of a subject-specific finite element model of a human clavicle
    Li, Zuoping
    Kindig, Matthew W.
    Kerrigan, Jason R.
    Kent, Richard W.
    Crandall, Jeff R.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (08) : 819 - 829
  • [27] Total Knee Replacement: Subject-Specific Modeling, Finite Element Analysis, and Evaluation of Dynamic Activities
    Loi, Iliana
    Stanev, Dimitar
    Moustakas, Konstantinos
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [28] Achilles tendon stress is more sensitive to subject-specific geometry than subject-specific material properties: A finite element analysis
    Hansen, Wencke
    Shim, Vickie B.
    Obst, Steven
    Lloyd, David G.
    Newsham-West, Richard
    Barrett, Rod S.
    JOURNAL OF BIOMECHANICS, 2017, 56 : 26 - 31
  • [29] An Image Registration-Based Morphing Technique for Generating Subject-Specific Brain Finite Element Models
    J. Sebastian Giudice
    Ahmed Alshareef
    Taotao Wu
    Christina A. Gancayco
    Kristen A. Reynier
    Nicholas J. Tustison
    T. Jason Druzgal
    Matthew B. Panzer
    Annals of Biomedical Engineering, 2020, 48 : 2412 - 2424
  • [30] Are subject-specific models necessary to predict patellar tendon fatigue life? A finite element modelling study
    Firminger, Colin R.
    Haider, Ifaz T.
    Bruce, Olivia L.
    Wannop, John W.
    Stefanyshyn, Darren J.
    Edwards, W. Brent
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (07) : 729 - 739