A Novel electronic chain for high level neutron coincidence counters

被引:3
|
作者
Fazzi, A
Pirovano, C
Varoli, V
机构
[1] Politecnico di Milano, Dip. Ingegneria Nucleare, Milano 20133
关键词
D O I
10.1109/23.603710
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a counting chain (charge preamplifier, shaping amplifier and threshold discriminator) devoted to He-3 neutron detectors. The preamplifier adopts an innovative circuit with the gate of the input JFET floating and a DC feedback loop that stabilizes the output voltage acting on the input cascade second transistor. Static and dynamic analysis, including the effects of the detector bias network, is developed and reported. The shaping amplifier is a fifth-order quasi-gaussian OPAMP active filter that minimizes the number of components. Shaping time constants ranging from 1 mu s down to 100 ns are explored in order to maximize the count rate capability, maintaining nevertheless neutron discrimination. Experimental signals and spectra show that 100 ns shaping time is a lower limit for the usual He-3 proportional detector. Since this counting chain is characterized by single 5V supply operation, high counting rate, small size and low cost, it is well suited for high efficiency neutron well detectors where a large number (10 - 100) of counting tubes are used (High Level Neutron Coincidence Counter HLNCC).
引用
收藏
页码:557 / 562
页数:6
相关论文
共 50 条
  • [21] IMPROVED PERFORMANCE OF BF3 NEUTRON COUNTERS IN HIGH GAMMA FLUXES
    STOKES, AJ
    MEAL, TJ
    MYERS, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (01) : 630 - &
  • [22] Electronic neutron dosimeter in high-energy neutron fields
    Wielunski, M.
    Brall, T.
    Dommert, M.
    Trinkl, S.
    Ruehm, W.
    Mares, V.
    RADIATION MEASUREMENTS, 2018, 114 : 12 - 18
  • [23] A HIGH RESOLUTION COINCIDENCE INSTRUMENT WITH SCINTILLATION COUNTERS - DELAYED AND PROMPT COINCIDENCES IN THE DECAY OF HF-181
    DEWAARD, H
    PHYSICA, 1952, 18 (12): : 1151 - 1156
  • [24] COMPUTER CONTROLLED, HIGH PERFORMANCE NEUTRON COINCIDENCE COUNTING SYSTEM.
    Lightfoot, J.A.
    Toon, G.
    Nuclear instruments and methods in physics research, 1988, A271 (03): : 636 - 643
  • [25] Simulation study of detection efficiency and precision on a novel coincidence neutron spectrometer technique
    Xia, Yan
    He, Shiyi
    Fan, Peng
    Ma, Tianyu
    Zhao, Chunqing
    Ding, Yigang
    Shen, Zicai
    Yang, Yanbin
    Zhou, Qin
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [26] Tissue-equivalent proportional counters in a high-energy neutron field at CERN
    Lim, T
    BottollierDepois, JF
    Festag, JG
    Golnik, H
    Grillmaier, RE
    Hofert, M
    Lindborg, L
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 300 - 305
  • [27] HIGH-ENERGY LIMITATIONS IN NEUTRON SPECTROMETRY WITH PROTON-RECOIL PROPORTIONAL COUNTERS
    YULE, TJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01): : 269 - &
  • [28] Neutron detector of high-efficiency arrays of BF3 proportional counters
    Fan, Rui-Feng
    Ma, Jing-Fang
    Yang, De-Xin
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2004, 24 (03):
  • [29] A COMPUTER-CONTROLLED, HIGH-PERFORMANCE, NEUTRON COINCIDENCE COUNTING SYSTEM
    LIGHTFOOT, JA
    TOON, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03): : 636 - 643
  • [30] NOVEL CARRY PROPAGATION IN HIGH-SPEED SYNCHRONOUS COUNTERS AND DIVIDERS
    LARSSON, P
    YUAN, J
    ELECTRONICS LETTERS, 1993, 29 (16) : 1457 - 1458