A performance comparison of convolutional neural network-based image denoising methods: The effect of loss functions on low-dose CT images

被引:78
|
作者
Kim, Byeongjoon [1 ,2 ]
Han, Minah [1 ,2 ]
Shim, Hyunjung [1 ,2 ]
Baek, Jongduk [1 ,2 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Incheon 21983, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Incheon 21983, South Korea
基金
新加坡国家研究基金会;
关键词
adversarial loss; deep learning; feature-level loss; image denoising; low-dose CT; mathematical observer; modulation transfer function; noise power spectrum; NOISE; FRAMELETS; OBSERVER; SPECTRUM;
D O I
10.1002/mp.13713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Convolutional neural network (CNN)-based image denoising techniques have shown promising results in low-dose CT denoising. However, CNN often introduces blurring in denoised images when trained with a widely used pixel-level loss function. Perceptual loss and adversarial loss have been proposed recently to further improve the image denoising performance. In this paper, we investigate the effect of different loss functions on image denoising performance using task-based image quality assessment methods for various signals and dose levels. Methods We used a modified version of U-net that was effective at reducing the correlated noise in CT images. The loss functions used for comparison were two pixel-level losses (i.e., the mean-squared error and the mean absolute error), Visual Geometry Group network-based perceptual loss (VGG loss), adversarial loss used to train the Wasserstein generative adversarial network with gradient penalty (WGAN-GP), and their weighted summation. Each image denoising method was applied to reconstructed images and sinogram images independently and validated using the extended cardiac-torso (XCAT) simulation and Mayo Clinic datasets. In the XCAT simulation, we generated fan-beam CT datasets with four different dose levels (25%, 50%, 75%, and 100% of a normal-dose level) using 10 XCAT phantoms and inserted signals in a test set. The signals had two different shapes (spherical and spiculated), sizes (4 and 12 mm), and contrast levels (60 and 160 HU). To evaluate signal detectability, we used a detection task SNR (tSNR) calculated from a non-prewhitening model observer with an eye filter. We also measured the noise power spectrum (NPS) and modulation transfer function (MTF) to compare the noise and signal transfer properties. Results Compared to CNNs without VGG loss, VGG-loss-based CNNs achieved a more similar tSNR to that of the normal-dose CT for all signals at different dose levels except for a small signal at the 25% dose level. For a low-contrast signal at 25% or 50% dose, adding other losses to the VGG loss showed more improved performance than only using VGG loss. The NPS shapes from VGG-loss-based CNN closely matched that of normal-dose CT images while CNN without VGG loss overly reduced the mid-high-frequency noise power at all dose levels. MTF also showed VGG-loss-based CNN with better-preserved high resolution for all dose and contrast levels. It is also observed that additional WGAN-GP loss helps improve the noise and signal transfer properties of VGG-loss-based CNN. Conclusions The evaluation results using tSNR, NPS, and MTF indicate that VGG-loss-based CNNs are more effective than those without VGG loss for natural denoising of low-dose images and WGAN-GP loss improves the denoising performance of VGG-loss-based CNNs, which corresponds with the qualitative evaluation.
引用
收藏
页码:3906 / 3923
页数:18
相关论文
共 50 条
  • [1] Performance comparison of convolutional neural network based denoising in low dose CT images for various loss functions
    Kim, Byeongjoon
    Han, Minah
    Shim, Hyunjung
    Baek, Jongduk
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [2] Low-Dose CT Image Denoising Method Based on Convolutional Neural Network
    Zhang Yungang
    Yi Benshun
    Wu Chenyue
    Feng Yu
    ACTA OPTICA SINICA, 2018, 38 (04)
  • [3] Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography
    Keisuke Usui
    Koichi Ogawa
    Masami Goto
    Yasuaki Sakano
    Shinsuke Kyougoku
    Hiroyuki Daida
    Visual Computing for Industry, Biomedicine, and Art, 4
  • [4] Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography
    Usui, Keisuke
    Ogawa, Koichi
    Goto, Masami
    Sakano, Yasuaki
    Kyougoku, Shinsuke
    Daida, Hiroyuki
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2021, 4 (01)
  • [5] Low-dose CT denoising via convolutional neural network with an observer loss function
    Han, Minah
    Shim, Hyunjung
    Baek, Jongduk
    MEDICAL PHYSICS, 2021, 48 (10) : 5727 - 5742
  • [6] Image Denoising for Low-Dose CT via Convolutional Dictionary Learning and Neural Network
    Yan, Rongbiao
    Liu, Yi
    Liu, Yuhang
    Wang, Lei
    Zhao, Rongge
    Bai, Yunjiao
    Gui, Zhiguo
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 83 - 93
  • [7] A deeper convolutional neural network for denoising low dose CT images
    Kim, Byeongjoon
    Shim, Hyunjung
    Baek, Jongduk
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [8] Low-dose CT image denoising using residual convolutional network with fractional TV loss
    Chen, Miao
    Pu, Yi-Fei
    Bai, Yu-Cai
    NEUROCOMPUTING, 2021, 452 : 510 - 520
  • [9] Robust Denoising of Low-Dose CT Images using Convolutional Neural Networks
    Nguyen Thanh Trung
    Trinh Dinh Hoan
    Nguyen Linh Trung
    Luu Manh Ha
    PROCEEDINGS OF 2019 6TH NATIONAL FOUNDATION FOR SCIENCE AND TECHNOLOGY DEVELOPMENT (NAFOSTED) CONFERENCE ON INFORMATION AND COMPUTER SCIENCE (NICS), 2019, : 506 - 511
  • [10] Convolutional Neural Network-Based Robust Denoising of Low-Dose Computed Tomography Perfusion Maps
    Kadimesetty, Venkata S.
    Gutta, Sreedevi
    Ganapathy, Sriram
    Yalavarthy, Phaneendra K.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (02) : 137 - 152