A performance comparison of convolutional neural network-based image denoising methods: The effect of loss functions on low-dose CT images

被引:78
|
作者
Kim, Byeongjoon [1 ,2 ]
Han, Minah [1 ,2 ]
Shim, Hyunjung [1 ,2 ]
Baek, Jongduk [1 ,2 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Incheon 21983, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Incheon 21983, South Korea
基金
新加坡国家研究基金会;
关键词
adversarial loss; deep learning; feature-level loss; image denoising; low-dose CT; mathematical observer; modulation transfer function; noise power spectrum; NOISE; FRAMELETS; OBSERVER; SPECTRUM;
D O I
10.1002/mp.13713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Convolutional neural network (CNN)-based image denoising techniques have shown promising results in low-dose CT denoising. However, CNN often introduces blurring in denoised images when trained with a widely used pixel-level loss function. Perceptual loss and adversarial loss have been proposed recently to further improve the image denoising performance. In this paper, we investigate the effect of different loss functions on image denoising performance using task-based image quality assessment methods for various signals and dose levels. Methods We used a modified version of U-net that was effective at reducing the correlated noise in CT images. The loss functions used for comparison were two pixel-level losses (i.e., the mean-squared error and the mean absolute error), Visual Geometry Group network-based perceptual loss (VGG loss), adversarial loss used to train the Wasserstein generative adversarial network with gradient penalty (WGAN-GP), and their weighted summation. Each image denoising method was applied to reconstructed images and sinogram images independently and validated using the extended cardiac-torso (XCAT) simulation and Mayo Clinic datasets. In the XCAT simulation, we generated fan-beam CT datasets with four different dose levels (25%, 50%, 75%, and 100% of a normal-dose level) using 10 XCAT phantoms and inserted signals in a test set. The signals had two different shapes (spherical and spiculated), sizes (4 and 12 mm), and contrast levels (60 and 160 HU). To evaluate signal detectability, we used a detection task SNR (tSNR) calculated from a non-prewhitening model observer with an eye filter. We also measured the noise power spectrum (NPS) and modulation transfer function (MTF) to compare the noise and signal transfer properties. Results Compared to CNNs without VGG loss, VGG-loss-based CNNs achieved a more similar tSNR to that of the normal-dose CT for all signals at different dose levels except for a small signal at the 25% dose level. For a low-contrast signal at 25% or 50% dose, adding other losses to the VGG loss showed more improved performance than only using VGG loss. The NPS shapes from VGG-loss-based CNN closely matched that of normal-dose CT images while CNN without VGG loss overly reduced the mid-high-frequency noise power at all dose levels. MTF also showed VGG-loss-based CNN with better-preserved high resolution for all dose and contrast levels. It is also observed that additional WGAN-GP loss helps improve the noise and signal transfer properties of VGG-loss-based CNN. Conclusions The evaluation results using tSNR, NPS, and MTF indicate that VGG-loss-based CNNs are more effective than those without VGG loss for natural denoising of low-dose images and WGAN-GP loss improves the denoising performance of VGG-loss-based CNNs, which corresponds with the qualitative evaluation.
引用
收藏
页码:3906 / 3923
页数:18
相关论文
共 50 条
  • [41] BEST IN PHYSICS (IMAGING): Comparison of Loss Functions in Dual-Domain Convolutional Neural Networks for Low-Dose CT Enhancement
    Chung, K. J.
    Souza, R.
    Frayne, R.
    Lee, T. Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E271 - E271
  • [42] A convolutional neural network-based model observer for breast CT images
    Kim, Gihun
    Han, Minah
    Shim, Hyunjung
    Baek, Jongduk
    MEDICAL PHYSICS, 2020, 47 (04) : 1619 - 1632
  • [43] Separation-based model for low-dose CT image denoising
    Chen, Wenbin
    Bai, Junjie
    Gu, Xiaohua
    Li, Yuyan
    Shao, Yanling
    Zhang, Quan
    Liu, Yi
    Liu, Yanli
    Gui, Zhiguo
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (12): : 1198 - 1208
  • [44] Convolutional Neural Network-Based CT Image Segmentation of Kidney Tumours
    Hu, Cong
    Jiang, Wenwen
    Zhou, Tian
    Wan, Chunting
    Zhu, Aijun
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2024, 34 (04)
  • [45] Residual-based Convolutional-Neural-Network (CNN) for Low-dose CT Denoising: Impact of Multi-slice Input
    Zhou, Zhongxing
    Huber, Nathan R.
    Inoue, Akitoshi
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [46] A convolutional neural network for ultra-low-dose CT denoising and emphysema screening
    Zhao, Tingting
    McNitt-Gray, Michael
    Ruan, Dan
    MEDICAL PHYSICS, 2019, 46 (09) : 3941 - 3950
  • [47] Residual-based convolutional-neural-network (CNN) for low-dose CT denoising: impact of multi-slice input
    Zhou, Zhongxing
    Huber, Nathan R.
    Inoue, Akitoshi
    Cynthia, McCollough H.
    Yu, Lifeng
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2022, 12031
  • [48] 3D Residual Convolutional Neural Network for Low Dose CT Denoising
    Zamyatin, Alex
    Yu, Leiming
    Rozas, David
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [49] Low-Dose CT Image Denoising Using a Generative Adversarial Network With a Hybrid Loss Function for Noise Learning
    Ma, Yinjin
    Wei, Biao
    Feng, Peng
    He, Peng
    Guo, Xiaodong
    Wang, Ge
    IEEE ACCESS, 2020, 8 (08): : 67519 - 67529
  • [50] Gradient regularized convolutional neural networks for low-dose CT image enhancement
    Gou, Shuiping
    Liu, Wei
    Jiao, Changzhe
    Liu, Haofeng
    Gu, Yu
    Zhang, Xiaopeng
    Lee, Jin
    Jiao, Licheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):