A hydrogen peroxide biosensor with high stability based on gelatin-multiwalled carbon nanotubes modified glassy carbon electrode

被引:20
|
作者
Wang, Yulin [1 ]
Li, Tianyu [2 ]
Zhang, Weijie [1 ]
Huang, Yaqin [1 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Key Lab Carbon Fiber & Funct Polymers, Minist Educ, Beijing 100029, Peoples R China
[2] Tsinghua Univ, Dept Chem, Key Lab Organ Optoelect & Mol Engn, Beijing 100084, Peoples R China
关键词
Hydrogen peroxide biosensor; Multiwalled carbon nanotube; Gelatin; Catalase; Direct electrochemistry; GLUCOSE BIOSENSOR; HEMOGLOBIN; CATALASE; BIOELECTROCHEMISTRY; IMMOBILIZATION; NANOPARTICLES; SURFACES; FILM;
D O I
10.1007/s10008-014-2441-z
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A biosensor with high stability was prepared to determine hydrogen peroxide (H2O2). This hydrogen peroxide biosensor was obtained by modifying glassy carbon electrode (GCE) with a composite film composed of gelatin-multiwalled carbon nanotubes. Catalase (Cat) was covalently immobilized into gelatin-multiwalled carbon nanotubes modified GCE through the well-known glutaraldehyde (GAD) chemistry in order to enhance the stability of electrodes. The enzyme sensor can achieve direct electrochemical response of hydrogen peroxide. The cyclic voltammograms at different scan rates, electrochemical impedance spectroscopy (EIS), and scanning electron microscope (SEM) tests indicate that the enzyme sensor performs positively on increasing permeability, reducing the electron transfer resistance, and improving the electrode performance. The linear response of standard curve for H2O2 is in the range of 0.2 to 5.0 mM with a correlation coefficient of 0.9972, and the detection limit of 0.001 mM. A high operational and storage stability is demonstrated for the biosensor. The peak potential at room temperature in two consecutive weeks stays almost consistent, and the enzyme activity is kept stable even after 30 days in further study.
引用
收藏
页码:1981 / 1987
页数:7
相关论文
共 50 条
  • [1] A hydrogen peroxide biosensor with high stability based on gelatin-multiwalled carbon nanotubes modified glassy carbon electrode
    Yulin Wang
    Tianyu Li
    Weijie Zhang
    Yaqin Huang
    Journal of Solid State Electrochemistry, 2014, 18 : 1981 - 1987
  • [2] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Ren, Jing
    Kang, Tian-Fang
    Xue, Rui
    Ge, Chao-Nan
    Cheng, Shui-Yuan
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 303 - 309
  • [3] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Jing Ren
    Tian-Fang Kang
    Rui Xue
    Chao-Nan Ge
    Shui-Yuan Cheng
    Microchimica Acta, 2011, 174 : 303 - 309
  • [4] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes
    Tang, Wenwei
    Li, Lei
    Wu, Lujun
    Gong, Jiemin
    Zeng, Xinping
    PLOS ONE, 2014, 9 (05):
  • [5] Amperometric glucose sensor based on glucose oxidase immobilized on gelatin-multiwalled carbon nanotube modified glassy carbon electrode
    Periasamy, Arun Prakash
    Chang, Yu-Jung
    Chen, Shen-Ming
    BIOELECTROCHEMISTRY, 2011, 80 (02) : 114 - 120
  • [6] A Novel Hydrogen Peroxide Sensor Based on Multiwalled Carbon Nanotubes/Poly(pyrocatechol violet)-Modified Glassy Carbon Electrode
    Fang, Bin
    Zhang, Na
    Zhang, Wei
    Gu, Aixia
    Wang, Guangfeng
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 112 (06) : 3488 - 3493
  • [7] A hydrogen peroxide biosensor based on multiwalled carbon nanotubes-polyvinyl butyral film modified electrode
    Li Han
    Han Tao
    Minsheng Huang
    Yiming Zhang
    Shunbin Qiao
    Ruili Shi
    Russian Journal of Electrochemistry, 2016, 52 : 115 - 122
  • [8] A hydrogen peroxide biosensor based on multiwalled carbon nanotubes-polyvinyl butyral film modified electrode
    Han, Li
    Tao, Han
    Huang, Minsheng
    Zhang, Yiming
    Qiao, Shunbin
    Shi, Ruili
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (02) : 115 - 122
  • [9] Analytical Biosensing of Hydrogen Peroxide on Brilliant Cresyl Blue/Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode
    Peng, Ya-Yu
    Upadhyay, A. K.
    Chen, Shen-Ming
    ELECTROANALYSIS, 2010, 22 (04) : 463 - 470
  • [10] A norepinephrine biosensor based on a glassy carbon electrode modified with carbon nanotubes
    Mohammadi, Ali
    Moghaddam, Abdolmajid Bayandori
    Hosseini, Samanesadat
    Kazemzad, Mahmood
    Dinarvand, Rassoul
    ANALYTICAL METHODS, 2011, 3 (10) : 2406 - 2411