Development and Validation of a Rapid Column-Switching High-Performance Liquid Chromatographic Method for the Determination of Lamotrigine in Human Serum

被引:1
|
作者
del Rosario Brunetto, Maria [1 ]
Contreras, Yaritza [1 ]
Delgado, Yelitza [1 ]
Gallignani, Maximo [1 ]
Manuel Estela, Jose [2 ]
Cerda Martin, Victor [2 ]
机构
[1] Univ Los Andes, Fac Ciencias, Lab Espect Mol, Dept Quim, Merida 5101 A, Venezuela
[2] Univ Islas Baleares, Fac Ciencias, Dept Quim, Palma de Mallorca, Islas Baleares, Spain
关键词
ANTIEPILEPTIC DRUGS; CAPILLARY-ELECTROPHORESIS; PLASMA-CONCENTRATIONS; EPILEPSY; PHARMACOKINETICS; CARBAMAZEPINE; ANTICONVULSANTS; METABOLITES; EXTRACTION; SAMPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes a simple and sensitive column-switching high-performance liquid chromatographic method with UV detection for the determination of Lamotrigine in 50 mu L of serum. After solid-phase extraction of Lamotrigine on an Oasis HLB extraction precolumn (20 x 3.9 mm; dp: 25 mu m), chromatographic separation was achieved at 30 degrees C on a Chromolith RP-18e column (50 mm x 4.6 mm i.d.) using a solution of 20% acetonitrile in 15 mM phosphate buffer (pH 7.0) as the mobile phase, at a flow-rate of 2.0 mL/min. The eluant was detected at 215 nm. The retention time for Lamotrigine was 1.28 min. The total analysis time was ca. 5 min. However, the overlap of sample preparation, analysis, and reconditioning of the precolumn increased the overall sample throughput to one injection every 3 min. The method was validated for system suitability, linearity, precision, accuracy, robustness, and limit of quantitation. The linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.9996. Recovery studies achieved from Lamotrigine spiked plasma samples showed values greater than 93%, demonstrating the excellent extraction efficiency of the precolumn. Intra- and inter-day precision were generally acceptable; the coefficient of variation was < 2.3% in all cases. The detection limits for Lamotrigine at a signal-to-noise ratio of 3 was 0.002 mu g/mL when a sample volume of 50 mu L was injected. However, it was possible to enhance the sensitivity further by injecting larger volumes, up to 200 mu L. The method was shown to be robust and the results were within the acceptable range. The method was successfully applied to the determination of Lamotrigine in human serum samples of patients submitted to Lamotrigine therapy.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [31] Development of a simple column-switching high-performance liquid chromatography (HPLC) method for rapid and simultaneous routine serum monitoring of lamotrigine, oxcarbazepine and 10-monohydroxycarbazepine (MHD)
    Greiner, Christine
    Haen, Ekkehard
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 338 - 344
  • [32] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CIPROFLOXACIN IN SERUM USING AMBERLITE XAD-7
    LEE, HS
    ZEE, OP
    WOO, BH
    LEE, YJ
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1991, 26 (07): : 1253 - 1265
  • [33] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN-SWITCHING METHOD FOR 2 CYCLOSPORINE METABOLITES IN BLOOD
    GMUR, DJ
    MEIER, P
    YEE, GC
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (02): : 343 - 352
  • [34] Rapid and Simple Determination of Vitamin A and Vitamin E in Human Plasma by Column-Switching High-Performance Liquid Chromatography
    Sadilek, Petr
    Satinsky, Dalibor
    Ot'apka, Martin
    Sladkovsky, Radek
    Solich, Petr
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (04) : 311 - 315
  • [35] VALIDATION OF A COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC (HPLC) METHOD FOR DETERMINATION OF ML-1035 AND ITS 5 METABOLITES IN PLASMA
    KUO, BS
    POOLE, JC
    HWANG, KK
    PHARMACEUTICAL RESEARCH, 1992, 9 (01) : 119 - 125
  • [36] DETERMINATION OF CEFODIZIME IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    BOMPADRE, S
    FERRANTE, L
    LEONE, L
    DEMARTINIS, M
    GINALDI, L
    QUAGLINO, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (14): : 2895 - 2909
  • [37] Validated high-performance liquid chromatographic method for the determination of lamotrigine in human plasma
    Barbosa, NR
    Mídio, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 741 (02): : 289 - 293
  • [38] DETERMINATION OF ALFUZOSIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    CARLUCCI, G
    DIGIUSEPPE, E
    MAZZEO, P
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (18): : 3989 - 3997
  • [39] DETERMINATION OF THE POLAR DRUG DIMIRACETAM IN HUMAN PLASMA AND SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TORCHIO, L
    LOMBARDI, F
    VISCONTI, M
    DOYLE, E
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01): : 169 - 177
  • [40] High-performance liquid chromatographic determination of cefepime in human plasma and in urine and dialysis fluid using a column-switching technique
    Cherti, N
    Kinowski, JM
    Lefrant, JY
    Bressolle, F
    JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (02): : 377 - 386