COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CIPROFLOXACIN IN SERUM USING AMBERLITE XAD-7

被引:10
|
作者
LEE, HS [1 ]
ZEE, OP [1 ]
WOO, BH [1 ]
LEE, YJ [1 ]
机构
[1] SUNGKYUNKWAN UNIV,COLL PHARM,SUWON 440746,SOUTH KOREA
关键词
D O I
10.1080/10934529109375695
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A small precolumn (40 x 2 mm i.d.) packed with Amberlite XAD-7 facilitates the determination of ciprofloxacin in serum by permitting direct injection of a relatively small volume (100-mu-L) of diluted serum. A 0.05 M phosphate buffer (pH 7.0) washes out the plasma components. Acetonitrile-Methanol-5 mM tetrabutylammonium bromide (adjusted to pH 2.0 with phosphoric acid) (10:5:85, v/v) subsequently elutes the drug from the precolumn through the analytical column. This method shows excellent precision with good sensitivity and speed, and a detection limit of 0.1-mu-g/mL. The total analysis time per sample was less than 15 min, and the mean coefficients of variation for intra- and inter-assay were both less than 4.8%. The method has been successfully applied to serum samples from dogs and rats receiving oral administration of ciprofloxacin.
引用
收藏
页码:1253 / 1265
页数:13
相关论文
共 50 条
  • [1] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF VANCOMYCIN IN SERUM
    DEMOTESMAINARD, F
    LABAT, L
    VINCON, G
    BANNWARTH, B
    THERAPEUTIC DRUG MONITORING, 1994, 16 (03) : 293 - 297
  • [2] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CHLORPHENIRAMINE IN HUMAN SERUM USING COLUMN-SWITCHING
    YAMAGUCHI, M
    MONJI, H
    YAMASHITA, K
    AOKI, I
    YASHIKI, T
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01): : 168 - 172
  • [3] LIQUID-CHROMATOGRAPHIC ANALYSIS OF ANALGESICS ON AMBERLITE XAD-7
    BAUM, RG
    CANTWELL, FF
    ANALYTICAL CHEMISTRY, 1978, 50 (02) : 280 - 285
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PHENYLEPHRINE IN HUMAN SERUM USING COLUMN-SWITCHING WITH FLUORESCENCE DETECTION
    YAMAGUCHI, M
    MONJI, H
    AOKI, I
    YASHIKI, T
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01): : 93 - 99
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RIFAPENTINE IN SERUM USING COLUMN SWITCHING
    LEE, HS
    SHIN, HC
    HAN, SS
    ROH, JK
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 574 (01): : 175 - 178
  • [6] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF DICLOFENAC IN HUMAN PLASMA USING AUTOMATED COLUMN-SWITCHING
    MILLER, RB
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02): : 283 - 290
  • [7] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF ALPRAZOLAM IN PLASMA USING THE COLUMN-SWITCHING TECHNIQUE
    RIECK, W
    PLATT, D
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02): : 259 - 263
  • [8] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF A NEW ANTIVIRAL AGENT, CYCLARADINE, IN SERUM
    LIM, JM
    LIN, CC
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1986, 29 (06) : 977 - 979
  • [9] MODIFIED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE MEASUREMENT OF CYCLOSPORINE IN SERUM
    GMUR, DJ
    YEE, GC
    KENNEDY, MS
    JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV): : 422 - 427
  • [10] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROXYLYSYLPYRIDINOLINE AND LYSYLPYRIDINOLINE IN URINE USING A COLUMN-SWITCHING METHOD
    YOSHIMURA, Y
    OHNISHI, K
    HAMAMURA, M
    ODA, T
    SOHDA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 43 - 49