Development and Validation of a Rapid Column-Switching High-Performance Liquid Chromatographic Method for the Determination of Lamotrigine in Human Serum

被引:1
|
作者
del Rosario Brunetto, Maria [1 ]
Contreras, Yaritza [1 ]
Delgado, Yelitza [1 ]
Gallignani, Maximo [1 ]
Manuel Estela, Jose [2 ]
Cerda Martin, Victor [2 ]
机构
[1] Univ Los Andes, Fac Ciencias, Lab Espect Mol, Dept Quim, Merida 5101 A, Venezuela
[2] Univ Islas Baleares, Fac Ciencias, Dept Quim, Palma de Mallorca, Islas Baleares, Spain
关键词
ANTIEPILEPTIC DRUGS; CAPILLARY-ELECTROPHORESIS; PLASMA-CONCENTRATIONS; EPILEPSY; PHARMACOKINETICS; CARBAMAZEPINE; ANTICONVULSANTS; METABOLITES; EXTRACTION; SAMPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes a simple and sensitive column-switching high-performance liquid chromatographic method with UV detection for the determination of Lamotrigine in 50 mu L of serum. After solid-phase extraction of Lamotrigine on an Oasis HLB extraction precolumn (20 x 3.9 mm; dp: 25 mu m), chromatographic separation was achieved at 30 degrees C on a Chromolith RP-18e column (50 mm x 4.6 mm i.d.) using a solution of 20% acetonitrile in 15 mM phosphate buffer (pH 7.0) as the mobile phase, at a flow-rate of 2.0 mL/min. The eluant was detected at 215 nm. The retention time for Lamotrigine was 1.28 min. The total analysis time was ca. 5 min. However, the overlap of sample preparation, analysis, and reconditioning of the precolumn increased the overall sample throughput to one injection every 3 min. The method was validated for system suitability, linearity, precision, accuracy, robustness, and limit of quantitation. The linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.9996. Recovery studies achieved from Lamotrigine spiked plasma samples showed values greater than 93%, demonstrating the excellent extraction efficiency of the precolumn. Intra- and inter-day precision were generally acceptable; the coefficient of variation was < 2.3% in all cases. The detection limits for Lamotrigine at a signal-to-noise ratio of 3 was 0.002 mu g/mL when a sample volume of 50 mu L was injected. However, it was possible to enhance the sensitivity further by injecting larger volumes, up to 200 mu L. The method was shown to be robust and the results were within the acceptable range. The method was successfully applied to the determination of Lamotrigine in human serum samples of patients submitted to Lamotrigine therapy.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [21] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF BUSULFAN IN HUMAN SERUM WITH ONLINE DERIVATIZATION, COLUMN-SWITCHING AND ULTRAVIOLET ABSORBENCY DETECTION
    FUNAKOSHI, K
    YAMASHITA, K
    CHAO, WF
    YAMAGUCHI, M
    YASHIKI, T
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 660 (01): : 200 - 204
  • [22] Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma
    Ban, EM
    Maeng, JE
    Woo, JS
    Kim, CK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 230 - 235
  • [23] Simple and simultaneous determination of sulphapyridine and acetylsulphapyridine in human serum by column-switching high-performance liquid chromatography
    Teshima, D
    Hino, B
    Itoh, Y
    Oishi, R
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2002, 27 (06) : 403 - 408
  • [24] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF NEDOCROMIL SODIUM IN HUMAN URINE USING BIMODAL COLUMN-SWITCHING
    BAKER, PR
    GARDNER, JJ
    WILKINSON, D
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (01): : 59 - 65
  • [25] Development and Validation of a Column High-Performance Liquid Chromatographic Method for Determination of Sibutramine in Capsules
    Fracao Diefenbach, Isabel Cristina
    Friedrich, Milene
    Dos Santos, Marcos Roberto
    Bittencourt, Celso Figueiredo
    JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (01) : 148 - 151
  • [26] Column-switching high-performance liquid chromatographic assay for the determination of quercetin in human urine with ultraviolet absorbance detection
    Nielsen, SE
    Dragsted, LO
    JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2): : 81 - 89
  • [27] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROXYLYSYLPYRIDINOLINE AND LYSYLPYRIDINOLINE IN URINE USING A COLUMN-SWITCHING METHOD
    YOSHIMURA, Y
    OHNISHI, K
    HAMAMURA, M
    ODA, T
    SOHDA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 43 - 49
  • [28] DETERMINATION OF BROMPERIDOL IN SERUM BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    MIYAZAKI, T
    KOJIMA, N
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 : 227 - 234
  • [29] COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC (HPLC) DETERMINATION OF HYDROCHLOROTHIAZIDE IN RAT, DOG, AND HUMAN PLASMA
    KUO, BS
    MANDAGERE, A
    OSBORNE, DR
    HWANG, KK
    PHARMACEUTICAL RESEARCH, 1990, 7 (12) : 1257 - 1261
  • [30] Determination of aloesin in rat plasma using a column-switching high-performance liquid chromatographic assay
    Baek, M
    Jeong, JH
    Kim, DH
    JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (01): : 121 - 126