Ventilation/perfusion mismatch during lung aeration at birth

被引:33
|
作者
Lang, Justin A. R. [1 ,2 ]
Pearson, James T. [3 ,4 ]
te Pas, Arjan B. [5 ]
Wallace, Megan J. [1 ,2 ]
Siew, Melissa L. [1 ,2 ]
Kitchen, Marcus J. [6 ]
Fouras, Andreas [7 ]
Lewis, Robert A. [8 ,9 ]
Wheeler, Kevin I. [1 ,10 ]
Polglase, Graeme R. [1 ,2 ]
Shirai, Mikiyasu [11 ]
Sonobe, Takashi [11 ]
Hooper, Stuart B. [1 ,2 ]
机构
[1] MIMR PHI, Inst Med Res, Ritchie Ctr, Melbourne, Vic, Australia
[2] Monash Univ, Dept Obstet & Gynaecol, Melbourne, Vic 3004, Australia
[3] Monash Biomed Imaging, Melbourne, Vic, Australia
[4] Australian Synchrotron, Melbourne, Vic, Australia
[5] Leiden Univ, Med Ctr, Dept Pediat, Leiden, Netherlands
[6] Monash Univ, Sch Phys, Melbourne, Vic 3004, Australia
[7] Monash Univ, Dept Mech & Aerosp Engn, Melbourne, Vic 3004, Australia
[8] Monash Univ, Dept Mech & Aerosp Engn, Melbourne, Vic 3004, Australia
[9] Univ Saskatchewan, Dept Med Imaging, Saskatoon, SK, Canada
[10] Royal Hobart Hosp, Hobart, Tas, Australia
[11] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Cardiac Physiol, Osaka, Japan
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会; 澳大利亚研究理事会;
关键词
pulmonary blood flow; newborn; ventilation; perfusion; angiography; RAY PHASE-CONTRAST; SYNCHROTRON-RADIATION MICROANGIOGRAPHY; FUNCTIONAL RESIDUAL CAPACITY; BLOOD-FLOW DISTRIBUTION; PULMONARY-CIRCULATION; VASCULAR-RESISTANCE; PRETERM LAMBS; FETAL LAMBS; FETUS; STIMULATION;
D O I
10.1152/japplphysiol.01358.2013
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
At birth, the transition to newborn life is triggered by lung aeration, which stimulates a large increase in pulmonary blood flow (PBF). Current theories predict that the increase in PBF is spatially related to ventilated lung regions as they aerate after birth. Using simultaneous phase-contrast X-ray imaging and angiography we investigated the spatial relationships between lung aeration and the increase in PBF after birth. Six near-term (30-day gestation) rabbits were delivered by caesarean section, intubated and an intravenous catheter inserted, before they were positioned for X-ray imaging. During imaging, iodine was injected before ventilation onset, after ventilation of the right lung only, and after ventilation of both lungs. Unilateral ventilation increased iodine levels entering both left and right pulmonary arteries (PAs) and significantly increased heart rate, iodine ejection per beat, diameters of both left and right PAs, and number of visible vessels in both lungs. Within the 6th intercostal space, the mean gray level (relative measure of iodine level) increased from 68.3 +/- 11.6 and 70.3 +/- 7.5%.s to 136.3 +/- 22.6 and 136.3 +/- 23.7%.s in the left and right PAs, respectively. No differences were observed between vessels in the left and right lungs, despite the left lung not initially being ventilated. The increase in PBF at birth is not spatially related to lung aeration allowing a large ventilation/perfusion mismatch, or pulmonary shunting, to occur in the partially aerated lung at birth.
引用
收藏
页码:535 / 543
页数:9
相关论文
共 50 条
  • [21] VENTILATION PERFUSION MISMATCH IN INTERSTITIAL FIBROSIS
    RAWLINSON, J
    ACKERY, D
    CLINICAL NUCLEAR MEDICINE, 1988, 13 (12) : 878 - 879
  • [22] Diminished Redistribution of Aeration and Perfusion with Prone Ventilation in Late Stage Experimental Lung Injury
    Martin, K. T.
    Xin, Y.
    Herrmann, J.
    Gerard, S. E.
    Delvecchio, P.
    Humayun, S.
    Lenart, A.
    Sidhu, U.
    Abate, N.
    Petrov, M.
    Reutlinger, K.
    Staley, M.
    Esposito, S.
    Shen, J.
    Doiphode, A.
    Mulye, J.
    Tustison, N.
    Gee, J.
    Rizi, R. R.
    Cereda, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [23] TRANSIENT UNILATERAL REVERSE VENTILATION PERFUSION MISMATCH IN A PATIENT WITH LUNG-CANCER
    WATANABE, N
    HIRANO, T
    INOUE, T
    MATSUMOTO, M
    ORIUCHI, N
    TATENO, M
    MATSUMOTO, H
    NAGAMACHI, Y
    ENDO, K
    CLINICAL NUCLEAR MEDICINE, 1992, 17 (09) : 705 - 708
  • [24] Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung
    Tolnai, Jozsef
    Fodor, Gergely H.
    Babik, Barna
    Rocha, Andre Dos Santos
    Bayat, Sam
    Petak, Ferenc
    Habre, Walid
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [25] Effect of expiratory flow limitation on ventilation/perfusion mismatch and perioperative lung function during pneumoperitoneum and Trendelenburg position
    Fogagnolo, Alberto
    Spadaro, Savino
    Karbing, Dan S.
    Scaramuzzo, Gaetano
    Mari, Matilde
    Guirrini, Silvia
    Ragazzi, Riccardo
    Al-husinat, Lou'i
    Greco, Pantaleo
    Rees, Stephen E.
    Volta, Carlo A.
    MINERVA ANESTESIOLOGICA, 2023, 89 (09) : 733 - 743
  • [26] Partial ventilation perfusion mismatch in lung scintigraphy: Incidence and diagnostic implications.
    Lear, JL
    Lee, E
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 55P - 55P
  • [27] Improvement of Ventilation-Perfusion Mismatch by PEEP Is Correlated with Lung Recruitability in ARDS
    Mauri, T.
    Pavlovsky, B.
    Spinelli, E.
    Scaramuzzo, G.
    Marongiu, I.
    Tagliabue, P.
    Spadaro, S.
    Grasselli, G.
    Mercat, A.
    Pesenti, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [28] Diagnosis of pulmonary embolus using ventilation/perfusion lung scintigraphy: more than 0.5 segment of ventilation/perfusion mismatch is sufficient
    Howarth, DM
    Booker, JA
    Voutnis, DD
    INTERNAL MEDICINE JOURNAL, 2006, 36 (05) : 281 - 288
  • [29] VENTILATION AND PERFUSION OF EACH LUNG DURING DIFFERENTIAL VENTILATION WITH SELECTIVE PEEP
    HEDENSTIERNA, G
    BAEHRENDTZ, S
    KLINGSTEDT, C
    SANTESSON, J
    SODERBORG, B
    DAHLBORN, M
    BINDSLEV, L
    ANESTHESIOLOGY, 1984, 61 (04) : 369 - 376
  • [30] Optimization of ventilation-perfusion matching during protective lung ventilation
    Wu, CP
    Huang, KL
    Perng, WC
    Chang, H
    Chen, CW
    Su, CL
    Chuang, HL
    Yan, HC
    Huang, YC
    CHEST, 2005, 128 (04) : 225S - 226S