Ventilation/perfusion mismatch during lung aeration at birth

被引:33
|
作者
Lang, Justin A. R. [1 ,2 ]
Pearson, James T. [3 ,4 ]
te Pas, Arjan B. [5 ]
Wallace, Megan J. [1 ,2 ]
Siew, Melissa L. [1 ,2 ]
Kitchen, Marcus J. [6 ]
Fouras, Andreas [7 ]
Lewis, Robert A. [8 ,9 ]
Wheeler, Kevin I. [1 ,10 ]
Polglase, Graeme R. [1 ,2 ]
Shirai, Mikiyasu [11 ]
Sonobe, Takashi [11 ]
Hooper, Stuart B. [1 ,2 ]
机构
[1] MIMR PHI, Inst Med Res, Ritchie Ctr, Melbourne, Vic, Australia
[2] Monash Univ, Dept Obstet & Gynaecol, Melbourne, Vic 3004, Australia
[3] Monash Biomed Imaging, Melbourne, Vic, Australia
[4] Australian Synchrotron, Melbourne, Vic, Australia
[5] Leiden Univ, Med Ctr, Dept Pediat, Leiden, Netherlands
[6] Monash Univ, Sch Phys, Melbourne, Vic 3004, Australia
[7] Monash Univ, Dept Mech & Aerosp Engn, Melbourne, Vic 3004, Australia
[8] Monash Univ, Dept Mech & Aerosp Engn, Melbourne, Vic 3004, Australia
[9] Univ Saskatchewan, Dept Med Imaging, Saskatoon, SK, Canada
[10] Royal Hobart Hosp, Hobart, Tas, Australia
[11] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Cardiac Physiol, Osaka, Japan
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会; 澳大利亚研究理事会;
关键词
pulmonary blood flow; newborn; ventilation; perfusion; angiography; RAY PHASE-CONTRAST; SYNCHROTRON-RADIATION MICROANGIOGRAPHY; FUNCTIONAL RESIDUAL CAPACITY; BLOOD-FLOW DISTRIBUTION; PULMONARY-CIRCULATION; VASCULAR-RESISTANCE; PRETERM LAMBS; FETAL LAMBS; FETUS; STIMULATION;
D O I
10.1152/japplphysiol.01358.2013
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
At birth, the transition to newborn life is triggered by lung aeration, which stimulates a large increase in pulmonary blood flow (PBF). Current theories predict that the increase in PBF is spatially related to ventilated lung regions as they aerate after birth. Using simultaneous phase-contrast X-ray imaging and angiography we investigated the spatial relationships between lung aeration and the increase in PBF after birth. Six near-term (30-day gestation) rabbits were delivered by caesarean section, intubated and an intravenous catheter inserted, before they were positioned for X-ray imaging. During imaging, iodine was injected before ventilation onset, after ventilation of the right lung only, and after ventilation of both lungs. Unilateral ventilation increased iodine levels entering both left and right pulmonary arteries (PAs) and significantly increased heart rate, iodine ejection per beat, diameters of both left and right PAs, and number of visible vessels in both lungs. Within the 6th intercostal space, the mean gray level (relative measure of iodine level) increased from 68.3 +/- 11.6 and 70.3 +/- 7.5%.s to 136.3 +/- 22.6 and 136.3 +/- 23.7%.s in the left and right PAs, respectively. No differences were observed between vessels in the left and right lungs, despite the left lung not initially being ventilated. The increase in PBF at birth is not spatially related to lung aeration allowing a large ventilation/perfusion mismatch, or pulmonary shunting, to occur in the partially aerated lung at birth.
引用
收藏
页码:535 / 543
页数:9
相关论文
共 50 条
  • [11] REVERSE VENTILATION - PERFUSION MISMATCH
    PALMAZ, JC
    BARNETT, CA
    REICH, SB
    KRUMPE, PE
    FARRER, PA
    CLINICAL NUCLEAR MEDICINE, 1984, 9 (01) : 6 - 9
  • [12] Reverse ventilation/perfusion mismatch
    Kao, CH
    SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (02) : 183 - 185
  • [13] PULMONARY PERFUSION AND VENTILATION - A MISMATCH
    SCHATZMANN, U
    EQUINE VETERINARY JOURNAL, 1995, 27 (02) : 80 - 81
  • [14] Partial ventilation/perfusion mismatch in lung scintigraphy: Incidence and diagnostic implications
    Lear, JL
    Lee, E
    Baca, L
    Trujillo, NP
    RADIOLOGY, 1997, 205 : 1625 - 1625
  • [15] Diagnostic implications of partial ventilation perfusion mismatch-lung scintigraphy
    Lear, J
    Lee, E
    Trujillo, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1113 - 1113
  • [17] QUANTITATIVE ASSESSMENT OF VENTILATION-PERFUSION MISMATCH BY RADIOXENON IMAGING OF LUNG
    ISHII, Y
    ITOH, H
    SUZUKI, T
    YONEKURA, Y
    MUKAI, T
    TORIZUKA, K
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 607 - 614
  • [18] Endexpiratory lung volume measurement correlates with the ventilation/perfusion mismatch in lung injured pigs
    Jens Kamuf
    Andreas Garcia-Bardon
    Bastian Duenges
    Tanghua Liu
    Antje Jahn-Eimermacher
    Florian Heid
    Matthias David
    Erik K. Hartmann
    Respiratory Research, 18
  • [19] Endexpiratory lung volume measurement correlates with the ventilation/perfusion mismatch in lung injured pigs
    Kamuf, Jens
    Garcia-Bardon, Andreas
    Duenges, Bastian
    Liu, Tanghua
    Jahn-Eimermacher, Antje
    Heid, Florian
    David, Matthias
    Hartmann, Erik K.
    RESPIRATORY RESEARCH, 2017, 18
  • [20] Modern methods of assessment of lung aeration during mechanical ventilation
    Wierzejski, Wojciech
    Adamski, Jan
    Weigl, Wojciech
    Gerega, Anna
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2012, 44 (04) : 226 - 231