Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung

被引:8
|
作者
Tolnai, Jozsef [1 ]
Fodor, Gergely H. [2 ]
Babik, Barna [3 ]
Rocha, Andre Dos Santos [2 ]
Bayat, Sam [4 ]
Petak, Ferenc [1 ]
Habre, Walid [2 ]
机构
[1] Univ Szeged, Dept Med Phys & Informat, Szeged, Hungary
[2] Univ Geneva, Dept Anesthesiol Pharmacol & Intens Care, Unit Anesthesiol Invest, Geneva, Switzerland
[3] Univ Szeged, Dept Anesthesiol & Intens Therapy, Szeged, Hungary
[4] Univ Grenoble, Grenoble Univ Hosp, Dept Clin Physiol Sleep & Exercise, EA 7442 RSRM Lab, Grenoble, France
来源
FRONTIERS IN PHYSIOLOGY | 2018年 / 9卷
基金
瑞士国家科学基金会;
关键词
mechanical ventilation; acute respiratory distress syndrome; respiratory monitoring; lung injury; ventilation to perfusion ratio; capnography; DEAD-SPACE; PRESSURE; AIRWAY; MODEL;
D O I
10.3389/fphys.2018.01805
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Whereas time capnography (Tcap) is routinely displayed during mechanical ventilation, the volumetric representation (Vcap) is seldom used. We compared the diagnostic value of indices derived from Tcap and Vcap following ventilation to perfusion ratio (<(V)over dot>/<(Q)over dot>) mismatch subsequent to experimentally induced acute respiratory distress syndrome (ARDS), and alveolar recruitment by elevating the positive end-expiratory pressure (PEEP). Lung injury was induced by iv lipopolysaccharide, whole lung lavage and injurious ventilation in anesthetized, mechanically ventilated rabbits (n = 26). Mainstream Tcap and Vcap were performed to assess normalized phase 2 (Sn2(T), Sn2(V)) and phase 3 slopes (Sn3(T), Sn3(V)) in the time and volumetric domains. Vcap was also used to estimate Enghoff's physiological dead space (VDE). Lung oxygenation index (PaO2/FiO(2)) and intrapulmonary shunt (Qs/Qt) were derived from arterial and central venous blood gas samples. All measurements were made under baseline conditions, and, following lung injury, under moderate (6 cmH(2)O) and high PEEP levels (9 cmH(2)O). Lung injury deteriorated the PaO2/FiO(2) (baseline vs. injured 466 +/- 10.2 [95% confidence interval] vs. 77.3 +/- 17.1 mmHg, p < 0.05) and compromised all mechanical parameters significantly, whereas Tcap parameters exhibited contradictory or inconsistent changes. Conversely, Vcap indices exhibited consistent changes and provided excellent diagnostic value in detecting lung-function deterioration subsequent to lung injury [area under the receiver operating characteristic (ROC) curve of 1.0 +/- 0.0, 0.87 +/- 0.22 and 0.86 +/- 0.22 for VDE, Sn3(V) and Sn3(V)/Sn2(V), respectively]. Elevated PEEP increased PaO2/FiO(2) and decreased Qs/Qt, which was reflected only in the Vcap slope ratio (Sn3(V)/Sn2(V), p < 0.05). Our findings demonstrate the limited value of Tcap to detect ventilation to perfusion ratio (<(V)over dot>/<(Q)over dot>) mismatch, following severe lung injury. Conversely, indices derived from Vcap proved to be sensitive for detecting lung volume loss and alveolar recruitment. Therefore, promotion of Vcap is of paramount importance as a real-time, non-invasive, bedside monitoring modality to detect the development of and to follow-up the progression of lung injury in a model of ARDS.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Endexpiratory lung volume measurement correlates with the ventilation/perfusion mismatch in lung injured pigs
    Jens Kamuf
    Andreas Garcia-Bardon
    Bastian Duenges
    Tanghua Liu
    Antje Jahn-Eimermacher
    Florian Heid
    Matthias David
    Erik K. Hartmann
    Respiratory Research, 18
  • [2] Endexpiratory lung volume measurement correlates with the ventilation/perfusion mismatch in lung injured pigs
    Kamuf, Jens
    Garcia-Bardon, Andreas
    Duenges, Bastian
    Liu, Tanghua
    Jahn-Eimermacher, Antje
    Heid, Florian
    David, Matthias
    Hartmann, Erik K.
    RESPIRATORY RESEARCH, 2017, 18
  • [3] VENTILATION-PERFUSION MISMATCH - LUNG IMAGING
    WOOD, MJ
    CLINICAL NUCLEAR MEDICINE, 1983, 8 (04) : 181 - 181
  • [4] VENTILATION-PERFUSION MISMATCH - LUNG IMAGING
    DATZ, FL
    SEMINARS IN NUCLEAR MEDICINE, 1980, 10 (02) : 193 - 194
  • [5] Capnography reflects ventilation/perfusion distribution in a model of acute lung injury
    Tusman, G.
    Suarez-Sipmann, F.
    Bohm, S. H.
    Borges, J. B.
    Hedenstierna, G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (05) : 597 - 606
  • [6] Ventilation inhomogeneity assessed by nitrogen washout and ventilation-perfusion mismatch by capnography in stable and induced airway obstruction
    Strömberg, NOT
    Gustafsson, PM
    PEDIATRIC PULMONOLOGY, 2000, 29 (02) : 94 - 102
  • [7] EFFECT OF ANESTHETICS ON MATCHING OF VENTILATION AND PERFUSION IN THE INJURED LUNG
    DAHMS, TE
    SCHWEISS, JF
    BAUDENDISTEL, LJ
    ANESTHESIOLOGY, 1994, 81 (3A) : A1453 - A1453
  • [8] Ventilation/perfusion mismatch during lung aeration at birth
    Lang, Justin A. R.
    Pearson, James T.
    te Pas, Arjan B.
    Wallace, Megan J.
    Siew, Melissa L.
    Kitchen, Marcus J.
    Fouras, Andreas
    Lewis, Robert A.
    Wheeler, Kevin I.
    Polglase, Graeme R.
    Shirai, Mikiyasu
    Sonobe, Takashi
    Hooper, Stuart B.
    JOURNAL OF APPLIED PHYSIOLOGY, 2014, 117 (05) : 535 - 543
  • [9] Evaluation of effect of lung resection on lobar ventilation and perfusion using intrabronchial capnography
    Yoshimasu, T
    Miyoshi, S
    Maebeya, S
    Hirai, I
    Naito, Y
    CHEST, 1996, 109 (01) : 25 - 30
  • [10] Lactating breast producing a mismatch on ventilation perfusion lung scan
    Gallegos, E
    Balon, H
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (05) : 430 - 431