Dual-exposure technique for extending the dynamic range of x-ray flat panel detectors

被引:10
|
作者
Sisniega, A. [1 ,2 ]
Abella, M. [1 ,2 ]
Desco, M. [1 ,2 ,3 ]
Vaquero, J. J. [1 ,2 ]
机构
[1] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroespacial, Madrid, Spain
[2] IiSGM, Madrid, Spain
[3] Ctr Invest Red Salud Mental CIBERSAM, Madrid, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 02期
关键词
COMPUTED-TOMOGRAPHY; BREAST CT; RADIOGRAPHY; DESIGN; SYSTEM; NOISE;
D O I
10.1088/0031-9155/59/2/421
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work presents an approach to extend the dynamic range of x-ray flat panel detectors by combining two acquisitions of the same sample taken with two different x-ray photon flux levels and the same beam spectral configuration. In order to combine both datasets, the response of detector pixels was modelled in terms of mean and variance using a linear model. The model was extended to take into account the effect of pixel saturation. We estimated a joint probability density function (j-pdf) of the pixel values by assuming that each dataset follows an independent Gaussian distribution. This j-pdf was used for estimating the final pixel value of the high-dynamic-range dataset using amaximum likelihood method. The suitability of the pixel model for the representation of the detector signal was assessed using experimental data from a small-animal cone-beam micro-CT scanner equipped with a flat panel detector. The potential extension in dynamic range offered by our method was investigated for generic flat panel detectors using analytical expressions and simulations. The performance of the proposed dual-exposure approach in realistic imaging environments was compared with that of a regular single-exposure technique using experimental data from two different phantoms. Image quality was assessed in terms of signal-to-noise ratio, contrast, and analysis of profiles drawn on the images. The dynamic range, measured as the ratio between the exposure for saturation and the exposure equivalent to instrumentation noise, was increased from 76.9 to 166.7 when using our method. Dual-exposure results showed higher contrast-to-noise ratio and contrast resolution than the single-exposure acquisitions for the same x-ray dose. In addition, image artifacts were reduced in the combined dataset. This technique to extend the dynamic range of the detector without increasing the dose is particularly suited to image samples that contain both low and high attenuation regions.
引用
收藏
页码:421 / 439
页数:19
相关论文
共 50 条
  • [31] Development of a TLM to investigate the effect of a resistive interface in digital flat panel x-ray detectors
    Segui, J. A.
    Zhao, W.
    2007 IEEE 33RD ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2007, : 88 - 89
  • [32] X-ray photoconductors and stabilized a-Se for direct conversion digital flat-panel X-ray image-detectors
    Kasap, SO
    Rowlands, JA
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2000, 11 (03) : 179 - 198
  • [33] Video frame interpolation for high dynamic range sequences captured with dual-exposure sensors
    Cogalan, U.
    Bemana, M.
    Seidel, H. P.
    Myszkowski, K.
    COMPUTER GRAPHICS FORUM, 2023, 42 (02) : 119 - 131
  • [34] Reduction in operator X-ray exposure using a digital flat panel imaging system
    Ong, L
    Hajj-Ali, RH
    Marchant, D
    Green, S
    Katz, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 5A - 5A
  • [35] PHOTODIODES AS DETECTORS WITH HIGH DYNAMIC-RANGE FOR X-RAY REFLECTIVITY MEASUREMENTS
    STORB, C
    DEDEK, U
    WEBER, W
    LENGELER, B
    SCHUSTER, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (03): : 544 - 548
  • [36] A procedure for the dynamic range characterization of X-ray imaging linear and TDI detectors
    Re, Alessandro
    Peruzzi, Niccolo
    Del Greco, Filippo
    Nervo, Marco
    Pastrone, Nadia
    Sacchi, Roberto
    Lo Giudice, Alessandro
    JOURNAL OF INSTRUMENTATION, 2024, 19 (10):
  • [37] Fast and Wide Dynamic Range X-ray Detectors Enable Novel Science
    Philipp, H.
    Shanks, K.
    Tate, M.
    Weiss, J.
    Gruner, S.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C685 - C685
  • [38] Extended Dynamic Range CMOS Active Pixel Architecture for X-ray Detectors
    Maes, Willy H.
    Tousignant, Olivier
    Vullers, Ruud J. M.
    Kessener, Yves
    Miller, James J.
    Peters, Inge M.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [39] A High Dynamic Range CMOS Image Sensor With Dual-Exposure Charge Subtraction Scheme
    Qian, Xinyuan
    Yu, Hang
    Chen, Shoushun
    Low, Kay Soon
    IEEE SENSORS JOURNAL, 2015, 15 (02) : 661 - 662
  • [40] A new x-ray imaging technique for radiography mode of flat-panel imager
    Suzuki, K.
    Ikeda, S.
    Ueda, K.
    Baba, R.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510