Dual-exposure technique for extending the dynamic range of x-ray flat panel detectors

被引:10
|
作者
Sisniega, A. [1 ,2 ]
Abella, M. [1 ,2 ]
Desco, M. [1 ,2 ,3 ]
Vaquero, J. J. [1 ,2 ]
机构
[1] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroespacial, Madrid, Spain
[2] IiSGM, Madrid, Spain
[3] Ctr Invest Red Salud Mental CIBERSAM, Madrid, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 02期
关键词
COMPUTED-TOMOGRAPHY; BREAST CT; RADIOGRAPHY; DESIGN; SYSTEM; NOISE;
D O I
10.1088/0031-9155/59/2/421
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work presents an approach to extend the dynamic range of x-ray flat panel detectors by combining two acquisitions of the same sample taken with two different x-ray photon flux levels and the same beam spectral configuration. In order to combine both datasets, the response of detector pixels was modelled in terms of mean and variance using a linear model. The model was extended to take into account the effect of pixel saturation. We estimated a joint probability density function (j-pdf) of the pixel values by assuming that each dataset follows an independent Gaussian distribution. This j-pdf was used for estimating the final pixel value of the high-dynamic-range dataset using amaximum likelihood method. The suitability of the pixel model for the representation of the detector signal was assessed using experimental data from a small-animal cone-beam micro-CT scanner equipped with a flat panel detector. The potential extension in dynamic range offered by our method was investigated for generic flat panel detectors using analytical expressions and simulations. The performance of the proposed dual-exposure approach in realistic imaging environments was compared with that of a regular single-exposure technique using experimental data from two different phantoms. Image quality was assessed in terms of signal-to-noise ratio, contrast, and analysis of profiles drawn on the images. The dynamic range, measured as the ratio between the exposure for saturation and the exposure equivalent to instrumentation noise, was increased from 76.9 to 166.7 when using our method. Dual-exposure results showed higher contrast-to-noise ratio and contrast resolution than the single-exposure acquisitions for the same x-ray dose. In addition, image artifacts were reduced in the combined dataset. This technique to extend the dynamic range of the detector without increasing the dose is particularly suited to image samples that contain both low and high attenuation regions.
引用
收藏
页码:421 / 439
页数:19
相关论文
共 50 条
  • [1] Automated Dual-Exposure Technique to Extend the Dynamic Range of Flat-Panel Detectors Used in Small-Animal Cone-Beam Micro-CT
    Sisniega, Alejandro
    Vaquero, Juan J.
    Abella, Monica
    Vidal Migallon, Irina
    Lage, Eduardo
    Desco, Manuel
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2948 - 2950
  • [2] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [3] Dual-energy technique for digital flat-panel detectors without x-ray tube voltage switching
    Coello, Christopher S.
    Dinten, Jean-Marc
    Arques, Marc
    Rohr, Pierre
    Odet, Christophe
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [4] New materials and processes for flat panel X-ray detectors
    Street, RA
    Lu, JP
    Ready, SR
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2003, 150 (04): : 250 - 257
  • [5] Temporal artefacts in flat dynamic X-ray detectors
    Overdick, M
    Solf, T
    Wischmann, HA
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 47 - 58
  • [6] Dynamic defectoscopy with flat panel and CdTe Timepix X-ray detectors combined with an optical camera
    Vavrik, D.
    Fauler, A.
    Fiederle, M.
    Jandejsek, I.
    Jakubek, M.
    Turecek, D.
    Zwerger, A.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications
    Hata, Akinori
    Yamada, Yoshitake
    Tanaka, Rie
    Nishino, Mizuki
    Hida, Tomoyuki
    Hino, Takuya
    Ueyama, Masako
    Yanagawa, Masahiro
    Kamitani, Takeshi
    Kurosaki, Atsuko
    Sanada, Shigeru
    Jinzaki, Masahiro
    Ishigami, Kousei
    Tomiyama, Noriyuki
    Honda, Hiroshi
    Kudoh, Shoji
    Hatabu, Hiroto
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (04) : 634 - 651
  • [8] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [9] A semiempirical linear model of indirect, flat-panel x-ray detectors
    Huang, Shih-Ying
    Yang, Kai
    Abbey, Craig K.
    Boone, John M.
    MEDICAL PHYSICS, 2012, 39 (04) : 2108 - 2118
  • [10] Properties of a-Se for use in flat panel X-ray image detectors
    Kasap, SO
    Haugen, C
    Nesdoly, M
    Rowlands, JA
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2000, 266 : 1163 - 1167