Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols

被引:0
|
作者
Dacunto, Philip J. [1 ,2 ]
Klepeis, Neil E. [1 ,3 ]
Cheng, Kai-Chung [1 ]
Acevedo-Bolton, Viviana [1 ]
Jiang, Ruo-Ting [1 ]
Repace, James L. [4 ]
Ott, Wayne R. [1 ]
Hildemann, Lynn M. [1 ]
机构
[1] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
[2] US Mil Acad, Dept Geog & Environm Engn, West Point, NY 10996 USA
[3] San Diego State Univ Res Fdn, Grad Sch Publ Hlth, Ctr Behav Epidemiol & Community Hlth CBEACH, San Diego, CA 92123 USA
[4] Repace Associates, Bowie, MD 20720 USA
关键词
OUTDOOR;
D O I
10.1039/c5em00365b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak T Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 mm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. mg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.
引用
收藏
页码:1959 / 1966
页数:8
相关论文
共 50 条
  • [31] One year evaluation of three low-cost PM2.5 monitors
    Zamora, Misti Levy
    Rice, Jessica
    Koehler, Kirsten
    ATMOSPHERIC ENVIRONMENT, 2020, 235
  • [32] Evaluation of PM2.5 measured in an urban setting using a low-cost optical particle counter and a Federal Equivalent Method Beta Attenuation Monitor
    Magi, Brian I.
    Cupini, Calvin
    Francis, Jeff
    Green, Megan
    Hauser, Cindy
    AEROSOL SCIENCE AND TECHNOLOGY, 2020, 54 (02) : 147 - 159
  • [33] Estimating Hourly Concentrations of PM2.5 across a Metropolitan Area Using Low-Cost Particle Monitors
    Zikova, Nadezda
    Masiol, Mauro
    Chalupa, David C.
    Rich, David Q.
    Ferro, Andrea R.
    Hopke, Philip K.
    SENSORS, 2017, 17 (08)
  • [34] Characterizing outdoor infiltration and indoor contribution of PM2.5 with citizen-based low-cost monitoring data
    Bi, Jianzhao
    Wallace, Lance A.
    Sarnat, Jeremy A.
    Liu, Yang
    ENVIRONMENTAL POLLUTION, 2021, 276
  • [35] Evaluations of Low-cost Air Quality Sensors for Particulate Matter (PM2.5) under Indoor and Outdoor Conditions
    Rabuan, Utbah
    Nadzir, Mohd Shahrul Mohd
    Sham, Siti Zahanah Abdullah
    Bahri, Sharifah Batrisyia Izzati Wan Shaiful
    Borah, Jintu
    Majumdar, Shubhankar
    Lei, Thomas M. T.
    Ali, Sawal Hamid Md
    Wahab, Muhammad Ikram A.
    Yunus, Noor Hidayah Mohd
    SENSORS AND MATERIALS, 2023, 35 (08) : 2881 - 2895
  • [36] Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
    Huang, Ching-Hsuan
    He, Jiayang
    Austin, Elena
    Seto, Edmund
    Novosselov, Igor
    PLOS ONE, 2021, 16 (11):
  • [37] An efficient spatiotemporal data calibration approach for the low-cost PM2.5 sensing network: A case study in Taiwan
    Lee, Chieh-Han
    Wang, Yeuh-Bin
    Yu, Hwa-Lung
    ENVIRONMENT INTERNATIONAL, 2019, 130
  • [38] Publicly available low-cost sensor measurements for PM2.5 exposure modeling: Guidance for monitor deployment and data selection
    Bi, Jianzhao
    Carmona, Nancy
    Blanco, Magali N.
    Gassett, Amanda J.
    Seto, Edmund
    Szpiro, Adam A.
    V. Larson, Timothy
    Sampson, Paul D.
    Kaufman, Joel D.
    Sheppard, Lianne
    ENVIRONMENT INTERNATIONAL, 2022, 158
  • [39] A Low-Cost Liquid-Based Capacitive Sensor for PM2.5 Monitoring
    Ashoori, Ehsan
    Parsnejad, Sina
    Yin, Heyu
    Figueroa, J.
    Sepulveda, N.
    Mason, Andrew J.
    2021 IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2021, : 907 - 910
  • [40] Improved PM2.5 concentration estimates from low-cost sensors using calibration models categorized by relative humidity
    Hua, Jinxi
    Zhang, Yuanxun
    de Foy, Benjamin
    Mei, Xiaodong
    Shang, Jing
    Zhang, Yang
    Sulaymon, Ishaq Dimeji
    Zhou, Dandan
    AEROSOL SCIENCE AND TECHNOLOGY, 2021, 55 (05) : 600 - 613