Simulation studies of CZT detectors as gamma-ray calorimeter

被引:4
|
作者
Jung, I. [1 ]
Krawczynski, H. [1 ]
Komarov, S. [1 ]
Sobotka, L. [1 ]
机构
[1] Washington Univ, Dept Phys, St Louis, MO 63130 USA
关键词
CdZnTe; CZT detectors; astronomy; nuclear physics; MeV gamma-ray astronomy;
D O I
10.1016/j.astropartphys.2006.05.009
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications cadmium zinc telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and similar to 1 MeV. They operate at room temperature and achieve excellent position resolution and substantially better energy resolution than scintillation detectors. Furthermore, they can be built more compact and more economically than Ge detectors and do not require cryogenic cooling. In this paper, we describe the results of 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. The main objective of these studies is to evaluate the feasibility of CZT calorimeters, to study their performance and detect and understand performance limiting factors. Such a calorimeter consists of many layers of closely packed pixellated CZT detector units. Our simulations of single detector units reproduce experimental results, indicating that our simulations capture the main factors that limit the performance of a detector unit. For a full calorimeter the limiting factors within a range from similar to 20 keV to similar to 10 MeV are (a) the fact, that the incident energy is not totally deposited within the detector area because secondary particles leave the detector against the direction from which the incident radiation enters, (b) signal loss when the interaction is near the pixel edges and near the anodes. In this case signals which are induced in neighboring pixels are discarded when their intensities lie below the trigger threshold, (c) the steep weighting potential gradient close to the anodes, which affects about 0.25 cm next to the anode and impairs there the correction of the depth of interaction (DOI). This effect dominates in thin detectors (0.5 cm). Understanding the limiting factors we come to the conclusion that 1-1.5 cm thick detector units can be used to build a calorimeter with good performance over the energy range from similar to 20 keV to similar to 10 MeV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 50 条
  • [41] Use of Monte Carlo simulation to examine gamma-ray interactions in germanium detectors
    Kamboj, S
    Kahn, B
    RADIATION MEASUREMENTS, 2003, 37 (01) : 1 - 8
  • [42] GAMMA-RAY ENERGY DEPOSITION IN SILICON DETECTORS
    LURIE, NA
    STEINMAN, DK
    HARRIS, L
    WONDRA, JP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, 22 (06) : 2582 - 2585
  • [43] Recent developments in semiconductor gamma-ray detectors
    P. N. Luke
    M. Amman
    C. Tindall
    J. S. Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 145 - 153
  • [44] Recent Development of TlBr Gamma-Ray Detectors
    Tanaka, Tomonobu
    Hitomi, Keitaro
    Tada, Tsutomu
    Kim, Seong-Yun
    Wu, Yan
    Shoji, Tadayoshi
    Yamazaki, Hiromichi
    Ishii, Keizo
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3927 - 3931
  • [45] Recent Development of TlBr Gamma-Ray Detectors
    Hitomi, Keitaro
    Tada, Tsutomu
    Kim, Seong-Yun
    Wu, Yan
    Tanaka, Tomonobu
    Shoji, Tadayoshi
    Yamazaki, Hiromichi
    Ishii, Keizo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (04) : 1987 - 1991
  • [46] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2434 - 2438
  • [47] GAMMA-RAY DETECTORS WITH HGCDTE CONTACT LAYERS
    RYAN, FJ
    SHIN, SH
    EDWALL, DD
    PASKO, JG
    KHOSHNEVISAN, M
    WESTMARK, CI
    FULLER, C
    APPLIED PHYSICS LETTERS, 1985, 46 (03) : 274 - 276
  • [48] DISPERSION OF AMPLITUDE SPECTRUM OF GAMMA-RAY DETECTORS
    KATKOV, VP
    KRUPMAN, AI
    TAKSAR, IM
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1972, 5 (07): : 1214 - +
  • [49] Gamma-ray tracking with segmented HPGe detectors
    Wieland, O
    Kröll, T
    Bazzacco, D
    Venturelli, R
    Camera, F
    Million, B
    Musso, E
    Quintana, B
    Ur, CA
    Bellato, M
    Isocrate, R
    Manea, C
    Menegazzo, R
    Pavan, P
    Alvarez, CR
    Farnea, E
    Gadea, A
    Rosso, D
    Spolaore, R
    Pullia, A
    Casati, G
    Geraci, A
    Ripamonti, G
    Descovich, M
    BRAZILIAN JOURNAL OF PHYSICS, 2003, 33 (02) : 206 - 210
  • [50] Development of neutron shields for gamma-ray detectors
    Hong, J
    Hailey, CJ
    Craig, WW
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 121 - 131