Simulation studies of CZT detectors as gamma-ray calorimeter

被引:4
|
作者
Jung, I. [1 ]
Krawczynski, H. [1 ]
Komarov, S. [1 ]
Sobotka, L. [1 ]
机构
[1] Washington Univ, Dept Phys, St Louis, MO 63130 USA
关键词
CdZnTe; CZT detectors; astronomy; nuclear physics; MeV gamma-ray astronomy;
D O I
10.1016/j.astropartphys.2006.05.009
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications cadmium zinc telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and similar to 1 MeV. They operate at room temperature and achieve excellent position resolution and substantially better energy resolution than scintillation detectors. Furthermore, they can be built more compact and more economically than Ge detectors and do not require cryogenic cooling. In this paper, we describe the results of 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. The main objective of these studies is to evaluate the feasibility of CZT calorimeters, to study their performance and detect and understand performance limiting factors. Such a calorimeter consists of many layers of closely packed pixellated CZT detector units. Our simulations of single detector units reproduce experimental results, indicating that our simulations capture the main factors that limit the performance of a detector unit. For a full calorimeter the limiting factors within a range from similar to 20 keV to similar to 10 MeV are (a) the fact, that the incident energy is not totally deposited within the detector area because secondary particles leave the detector against the direction from which the incident radiation enters, (b) signal loss when the interaction is near the pixel edges and near the anodes. In this case signals which are induced in neighboring pixels are discarded when their intensities lie below the trigger threshold, (c) the steep weighting potential gradient close to the anodes, which affects about 0.25 cm next to the anode and impairs there the correction of the depth of interaction (DOI). This effect dominates in thin detectors (0.5 cm). Understanding the limiting factors we come to the conclusion that 1-1.5 cm thick detector units can be used to build a calorimeter with good performance over the energy range from similar to 20 keV to similar to 10 MeV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 50 条
  • [21] Characterization of single-sided charge-sharing CZT strip detectors for gamma-ray astronomy
    Donmez, Burcin
    Macri, John R.
    Ryan, James M.
    Legere, Jason S.
    McConnell, Mark L.
    Widholm, Mark
    Narita, Tomohiko
    Hamel, Louis-Andre
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [22] ENERGY CALORIMETER FOR A COSMIC GAMMA-RAY DETECTOR
    SOOD, RK
    ROCHESTER, GK
    CLAYTON, PG
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 311 - 313
  • [23] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [24] COMPUTER-SIMULATION OF AN ARRAY OF GE DETECTORS FOR GAMMA-RAY IMAGING
    ARISTE, JEN
    ALBERNHE, F
    VEDRENNE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (01): : 170 - 177
  • [25] Charge sharing on monolithic CdZnTe gamma-ray detectors:: A simulation study
    d'Aillon, Eric Gros
    Tabary, Joachim
    Gliere, Alain
    Verger, Loick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 124 - 127
  • [26] APPLICATIONS OF GERMANIUM GAMMA-RAY DETECTORS
    SHIRLEY, DA
    NUCLEONICS, 1965, 23 (03): : 62 - &
  • [27] Modeling of the stacked gamma-ray detectors
    Samui, A.
    Kshetri, R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (03)
  • [28] GAMMA-RAY IMAGING WITH GERMANIUM DETECTORS
    MAHONEY, WA
    CALLAS, JL
    LING, JC
    RADOCINSKI, RG
    SKELTON, RT
    VARNELL, LS
    WHEATON, WA
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1993, 97 (01): : 385 - 388
  • [29] Sensitivity of gamma-ray detectors to polarization
    Yadigaroglu, IA
    EXPERIMENTAL ASTRONOMY, 1997, 7 (03) : 221 - 237
  • [30] ADVANCES IN CDTE GAMMA-RAY DETECTORS
    SERREZE, HB
    ENTINE, G
    BELL, RO
    WALD, FV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 404 - 407