Simulation studies of CZT detectors as gamma-ray calorimeter

被引:4
|
作者
Jung, I. [1 ]
Krawczynski, H. [1 ]
Komarov, S. [1 ]
Sobotka, L. [1 ]
机构
[1] Washington Univ, Dept Phys, St Louis, MO 63130 USA
关键词
CdZnTe; CZT detectors; astronomy; nuclear physics; MeV gamma-ray astronomy;
D O I
10.1016/j.astropartphys.2006.05.009
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications cadmium zinc telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and similar to 1 MeV. They operate at room temperature and achieve excellent position resolution and substantially better energy resolution than scintillation detectors. Furthermore, they can be built more compact and more economically than Ge detectors and do not require cryogenic cooling. In this paper, we describe the results of 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. The main objective of these studies is to evaluate the feasibility of CZT calorimeters, to study their performance and detect and understand performance limiting factors. Such a calorimeter consists of many layers of closely packed pixellated CZT detector units. Our simulations of single detector units reproduce experimental results, indicating that our simulations capture the main factors that limit the performance of a detector unit. For a full calorimeter the limiting factors within a range from similar to 20 keV to similar to 10 MeV are (a) the fact, that the incident energy is not totally deposited within the detector area because secondary particles leave the detector against the direction from which the incident radiation enters, (b) signal loss when the interaction is near the pixel edges and near the anodes. In this case signals which are induced in neighboring pixels are discarded when their intensities lie below the trigger threshold, (c) the steep weighting potential gradient close to the anodes, which affects about 0.25 cm next to the anode and impairs there the correction of the depth of interaction (DOI). This effect dominates in thin detectors (0.5 cm). Understanding the limiting factors we come to the conclusion that 1-1.5 cm thick detector units can be used to build a calorimeter with good performance over the energy range from similar to 20 keV to similar to 10 MeV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 50 条
  • [31] DIIODIDE CRYSTALS FOR GAMMA-RAY DETECTORS
    ZALETIN, VM
    NOZHKINA, IN
    FOMIN, VI
    SHUSTOV, NV
    PROTASOV, II
    SOVIET ATOMIC ENERGY, 1980, 48 (03): : 191 - 194
  • [32] Up Down Gamma Discrimination using the Imaging Ratio Method with CZT Gamma-Ray Detectors for In Situ and Remote Sensing Operations
    Nowicki, Suzanne F.
    Hunter, Stanley D.
    Parsons, Ann. M.
    Chen, Henry
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [33] Evaluation of a CZT Gamma-Ray Detection Module Concept for SPECT
    Montemont, Guillaume
    Lux, Silvere
    Monnet, Olivier
    Stanchina, Sylvain
    Verger, Loick
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4091 - 4097
  • [34] Defects in CZT crystals and their relationship to gamma-ray detector performance
    Burger, A
    Chattopadhyay, K
    Chen, H
    Ma, X
    Ndap, JO
    Schieber, M
    Schlesinger, TE
    Yao, HW
    Erickson, J
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 586 - 590
  • [35] Development of an airborne gamma-ray spectrometer based on a CZT detector
    Joung, S.
    Ji, Y-Y
    Choi, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10):
  • [36] Liquid xenon gamma-ray calorimeter for the MEG experiment
    Iwamoto, Toshiyuki
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 325 - 332
  • [37] MONTE-CARLO SIMULATION OF GAMMA-RAY DETECTORS USING SCINTILLATION FIBERS
    CHANEY, RC
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 18 - 26
  • [38] Simulation and research of the gamma-ray detectors based on the CsI crystals and Silicon Photomultipliers
    Romanova, G. E.
    Radilov, A. V.
    Denisov, V. M.
    Bokatyi, I. O.
    Titov, A. B.
    OPTICAL SENSORS 2017, 2017, 10231
  • [39] SIMULATION OF THE TOTAL EFFICIENCY OF CYLINDRICAL SCINTILLATION GAMMA-RAY DETECTORS FOR DISK SOURCES
    Rehman, Shakeel U.
    Mirza, Sikander M.
    Mirza, Nasir M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (02): : 85 - 92
  • [40] Calorimeter calibration of the ComPol CubeSat gamma-ray polarimeter
    Cojocari, Ion
    Meier, Matthias
    Laurent, Philippe
    Laviron, Adrien
    Arrigucci, Marco
    Carminati, Marco
    Deda, Griseld
    Fiorini, Carlo
    Geigenberger, Katrin
    Glas, Cynthia
    Greiner, Jochen
    Hindenberger, Peter
    King, Pietro
    Lechner, Peter
    Losekamm, Martin
    Mertens, Susanne
    Messmann, David
    Ruckerl, Sebastian
    Toscano, Lorenzo
    Walter, Ulrich
    Willers, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1046