Off-pump transapical mitral valve replacement

被引:26
|
作者
Lutter, Georg [1 ]
Quaden, Rene [1 ]
Osaki, Satoru [2 ]
Hu, Jian [2 ]
Renner, Jochen [2 ]
Edwards, Niloo M. [3 ]
Cremer, Jochen [1 ]
Lozonschi, Lucian [3 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Cardiovasc Surg, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Anaesthesia, Kiel, Germany
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Cardiovasc Surg, Madison, WI USA
关键词
Valve replacement; Mitral; Off-pump; Catheter; Transapical; Transcatheter; Percutaneous; Minimally invasive; Valved stent; STENT;
D O I
10.1016/j.ejcts.2009.02.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Percutaneous valve replacement was recently introduced, and reports of early clinical experience have already been published. To date, this technique is limited to the replacement of pulmonary and aortic valves in a strictly selected group of patients. The aim of this study was to analyse a self-expanding valved stent for minimally invasive replacement of the mitral valve in animals. Methods: A newly designed nitinol stent was specially designed for this experimental acute study. It comprised of a left ventricular tubular stent with star shaped left atrial anchoring springs and carried a trileaflet bovine pericardial valve. A polytetrafluoroethylene membrane was sutured to envelop the atrial springs and the outside of the ventricular stent. The ventricular anchoring system was the same as in our previously reported results with a similar mitral valved stent. Seven pigs underwent minimally invasive off-pump mitral valved stent implantation. This was per-formed through a tower ministernotomy and a standard transapical approach under transoesophageal echocardiographic (TEE) guidance was used. Results: The valved stent is fully retrievable and precise deployment and accurate adjustment of its intra-annular position is achievable to eliminate paravalvular leakage. The deployment time ranged from 127 to 255 s and the blood loss from 70 to 220 cc. One animal died of intractable ventricular fibrillation. Mitral regurgitation in all surviving animals was minimal (trace in 5/6 and mild in 1/6 during echo examination; on the contrast ventriculogram no mitral insufficiency was observed except in one documented as mild paravalvular regurgitation). These animals remained haemodynamically stable (6/6) and without TEE or ventriculographic changes for 1 h. Conclusion: Implantation of a tricuspid bovine pericardial valved stent in the mitral position is feasible in pigs through a transcatheter approach. This was possible through a smaller delivery system than previously reported. Additional studies are required to demonstrate long-term feasibility, durability, and heart function. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. Ail rights reserved.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [41] Transapical off-pump echo-guided mitral valve repair with neochordae implantation mid-term outcomes
    Gerosa, Gino
    Nadali, Matteo
    Longinotti, Lorenzo
    Ponzoni, Matteo
    Caraffa, Raphael
    Fiocco, Alessandro
    Pradegan, Nicola
    Besola, Laura
    D'Onofrio, Augusto
    Bizzotto, Eleonora
    Bellu, Roberto
    Gentian, Denas
    Colli, Andrea
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (01) : 131 - 140
  • [42] Transapical Off-pump Echo-guided Mitral Valve Repair with Neochordae Implantation: 2-Years Results
    Colli, Andrea
    Bizzotto, Eleonora
    Manzan, Erica
    Besola, Laura
    Bellu, Roberto
    Fiocco, Alessandro
    Pradegan, Nicola
    Nadali, Matteo
    Gerosa, Gino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B23 - B23
  • [43] Minimally Invasive, Robotic, and Off-Pump Mitral Valve Surgery
    Woo, Y. Joseph
    Rodriguez, Evelio
    Atluri, Pavan
    Chitwood, W. Randolph, Jr.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2006, 18 (02) : 139 - 147
  • [44] Off-pump mitral valve repair: is less really more?
    Tomsic, Anton
    Klautz, Robert J. M.
    Palmen, Meindert
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (06) : 1147 - 1148
  • [45] Off-Pump Transapical Implantation of Artificial Neo-Chordae to Correct Mitral Regurgitation
    Seeburger, Joerg
    Rinaldi, Mauro
    Nielsen, Sten Lyager
    Salizzoni, Stefano
    Lange, Ruediger
    Schoenburg, Markus
    Alfieri, Ottavio
    Borger, Michael Andrew
    Mohr, Friedrich Wilhelm
    Aidietis, Audrius
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (09) : 914 - 919
  • [46] Transapical off-pump Neochord implantation on bileaflet prolapse to treat severe mitral regurgitation
    Colli, Andrea
    Bellu, Roberto
    Pittarello, Demetrio
    Gerosa, Gino
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (04) : 554 - 556
  • [47] Off-pump transapical closure of a mitral periprosthetic leak: a new approach to a difficult problem
    Gaia, Diego Felipe
    Breda, Joao Roberto
    Fischer, Claudio Henrique
    Palma, Jose Honorio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (06) : 1048 - 1050
  • [48] Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
    Chan, Daniel Tai-Leung
    Bhatia, Inderjeet
    Lam, Simon Chi-Cheung
    Au, Timmy Wing-Kuk
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 57 - 64
  • [49] Transapical off-pump mitral valve repair with neochord implantation: 6-months clinical and echocardiographic follow-up
    Colli, A.
    Zucchetta, F.
    Manzan, E.
    Bizzotto, E.
    Besola, L.
    Bellu, R.
    Pittarello, D.
    Gerosa, G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 28 - 28
  • [50] Off-pump tricuspid valve replacement for severe infective endocarditis
    Lee, Kun-Kuang
    Yu, Hsi-Yu
    Chen, Yih-Sharng
    Chi, Nai-Hsin
    Chang, Chung-I
    Wang, Shoei-Shen
    ANNALS OF THORACIC SURGERY, 2007, 84 (01): : 309 - 311