Off-pump transapical mitral valve replacement

被引:26
|
作者
Lutter, Georg [1 ]
Quaden, Rene [1 ]
Osaki, Satoru [2 ]
Hu, Jian [2 ]
Renner, Jochen [2 ]
Edwards, Niloo M. [3 ]
Cremer, Jochen [1 ]
Lozonschi, Lucian [3 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Cardiovasc Surg, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Anaesthesia, Kiel, Germany
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Cardiovasc Surg, Madison, WI USA
关键词
Valve replacement; Mitral; Off-pump; Catheter; Transapical; Transcatheter; Percutaneous; Minimally invasive; Valved stent; STENT;
D O I
10.1016/j.ejcts.2009.02.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Percutaneous valve replacement was recently introduced, and reports of early clinical experience have already been published. To date, this technique is limited to the replacement of pulmonary and aortic valves in a strictly selected group of patients. The aim of this study was to analyse a self-expanding valved stent for minimally invasive replacement of the mitral valve in animals. Methods: A newly designed nitinol stent was specially designed for this experimental acute study. It comprised of a left ventricular tubular stent with star shaped left atrial anchoring springs and carried a trileaflet bovine pericardial valve. A polytetrafluoroethylene membrane was sutured to envelop the atrial springs and the outside of the ventricular stent. The ventricular anchoring system was the same as in our previously reported results with a similar mitral valved stent. Seven pigs underwent minimally invasive off-pump mitral valved stent implantation. This was per-formed through a tower ministernotomy and a standard transapical approach under transoesophageal echocardiographic (TEE) guidance was used. Results: The valved stent is fully retrievable and precise deployment and accurate adjustment of its intra-annular position is achievable to eliminate paravalvular leakage. The deployment time ranged from 127 to 255 s and the blood loss from 70 to 220 cc. One animal died of intractable ventricular fibrillation. Mitral regurgitation in all surviving animals was minimal (trace in 5/6 and mild in 1/6 during echo examination; on the contrast ventriculogram no mitral insufficiency was observed except in one documented as mild paravalvular regurgitation). These animals remained haemodynamically stable (6/6) and without TEE or ventriculographic changes for 1 h. Conclusion: Implantation of a tricuspid bovine pericardial valved stent in the mitral position is feasible in pigs through a transcatheter approach. This was possible through a smaller delivery system than previously reported. Additional studies are required to demonstrate long-term feasibility, durability, and heart function. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. Ail rights reserved.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [31] Acute intraoperative echocardiographic changes after transapical off-pump mitral valve repair with NeoChord implantation
    Colli, Andrea
    Besola, Laura
    Montagner, Matteo
    Soriani, Nicola
    Manzan, Erica
    Bizzotto, Eleonora
    Zucchetta, Fabio
    Azzolina, Danila
    Bellu, Roberto
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 257 : 230 - 234
  • [32] Transapical off-pump mitral valve repair with NeoChord™ implantation: An early single-center Portuguese experience
    Goncalves-Teixeira, Pedro
    Costa, Sara
    Martins, Daniel
    Neves, Paulo
    Ribeiro, Jose
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (12) : 933 - 941
  • [33] Good 5-Year Durability of Transapical Beating Heart Off-Pump Mitral Valve Repair With Neochordae
    Kiefer, Philipp
    Meier, Sabine
    Noack, Thilo
    Borger, Michael Andrew
    Ender, Joerg
    Hoyer, Alexandro
    Mohr, Friedrich Wilhelm
    Seeburger, Joerg
    Gerosa, Gino
    ANNALS OF THORACIC SURGERY, 2018, 106 (02): : 440 - 446
  • [34] Transapical Off-Pump Valve-in-Valve Implantation in Patients With Degenerated Aortic Xenografts
    Kempfert, Joerg
    Van Linden, Arnaud
    Linke, Axel
    Borger, Michael A.
    Rastan, Ardawan
    Mukherjee, Chirojit
    Ender, Joerg
    Schuler, Gerhard
    Mohr, Friedrich W.
    Walther, Thomas
    ANNALS OF THORACIC SURGERY, 2010, 89 (06): : 1934 - 1941
  • [35] New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves
    Boudjemline, Y
    Pineau, E
    Borenstein, N
    Behr, L
    Bonhoeffer, P
    EUROPEAN HEART JOURNAL, 2005, 26 (19) : 2013 - 2017
  • [36] Transapical off-pump mitral valve repair with Neochord Implantation (TOP-MINI): step-by-step guide
    Colli, Andrea
    Zucchetta, Fabio
    Torregrossa, Gianluca
    Manzan, Erica
    Bizzotto, Eleonora
    Besola, Laura
    Bellu, Roberto
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    ANNALS OF CARDIOTHORACIC SURGERY, 2015, 4 (03) : 295 - 297
  • [37] Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation
    Gaia, Diego Felipe
    Palma, Jose Honorio
    Marcondes de Souza, Jose Augusto
    Stocco Guilhen, Jose Cicero
    Telis, Andre
    Fischer, Claudio Henrique
    Neves Duarte Ferreira, Carolina Baeta
    Buffolo, Enio
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2009, 24 (02): : 233 - 238
  • [38] Transapical aortic valve implantation and minimally invasive off-pump bypass surgery
    Ahad, Samir
    Baumbach, Hardy
    Hill, Stephan
    Franke, Ulrich F. W.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (02) : 248 - 249
  • [39] Transapical off-pump mitral valve repair. First experience with the NeoChord system in Poland (report of two cases)
    Wrobel, Krzysztof
    Kurnicka, Katarzyna
    Zygier, Marcin
    Dyk, Wojciech
    Wojdyga, Ryszard
    Zielinski, Dariusz
    Jarzebska, Malgorzata
    Juraszynski, Zbigniew
    Lichodziejewska, Barbara
    Pruszczyk, Piotr
    Biederman, Andrzej
    Speziali, Giovanni
    Kasten, Uwe
    KARDIOLOGIA POLSKA, 2017, 75 (01) : 7 - 12
  • [40] On-pump or off-pump transapical aortic valve implantation provides better clinical outcomes?
    Apostolakis, Efstratios E.
    Akinosoglou, Karolina
    Dougenis, Dimitrios
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (02) : 376 - 377