Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair

被引:0
|
作者
Chan, Daniel Tai-Leung [1 ]
Bhatia, Inderjeet [1 ]
Lam, Simon Chi-Cheung [2 ]
Au, Timmy Wing-Kuk [1 ]
机构
[1] Queen Mary Hosp, Dept Cardiothorac Surg, Room 308, New Clin Bldg, Hong Kong, Peoples R China
[2] Queen Mary Hosp, Dept Med, Div Cardiol, Hong Kong, Peoples R China
关键词
AtriClip; Atrial fibrillation; Minimally invasive cardiac surgery; NeoChord; Mitral valve repair; LIGATION; SURGERY;
D O I
10.1007/s10047-023-01383-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6-12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [1] Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
    Daniel Tai-Leung Chan
    Inderjeet Bhatia
    Simon Chi-Cheung Lam
    Timmy Wing-Kuk Au
    Journal of Artificial Organs, 2024, 27 : 57 - 64
  • [2] Feasibility of novel transapical off pump beating heart mitral valve repair in a patient with dextrocardia and situs inversus
    Bhatia, Inderjeet
    Chan, Daniel Tai-Leung
    Lam, Simon Chi-Cheung
    Au, Timmy Wing-Kuk
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (02) : 392 - 394
  • [3] Good 5-Year Durability of Transapical Beating Heart Off-Pump Mitral Valve Repair With Neochordae
    Kiefer, Philipp
    Meier, Sabine
    Noack, Thilo
    Borger, Michael Andrew
    Ender, Joerg
    Hoyer, Alexandro
    Mohr, Friedrich Wilhelm
    Seeburger, Joerg
    Gerosa, Gino
    ANNALS OF THORACIC SURGERY, 2018, 106 (02): : 440 - 446
  • [4] Safety, Feasibility And Efficacy Of Transapical Off-Pump Mitral Valve Repair With Neochord Implantation
    Colli, Andrea
    Manzan, Erica
    Zucchetta, Fabio
    Sarais, Cristiano
    Pittarello, Demetrio
    Gerosa, Gino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B234 - B235
  • [5] Ultrasound based mitral valve annulus tracking for off-pump beating heart mitral valve repair
    Li, Feng P.
    Rajchl, Martin
    Moore, John
    Peters, Terry M.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [6] A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair
    Li, Feng P.
    Rajchl, Martin
    Moore, John
    Peters, Terry M.
    MEDICAL PHYSICS, 2015, 42 (01) : 456 - 468
  • [7] Off-pump transapical mitral valve replacement
    Lutter, Georg
    Quaden, Rene
    Osaki, Satoru
    Hu, Jian
    Renner, Jochen
    Edwards, Niloo M.
    Cremer, Jochen
    Lozonschi, Lucian
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (01) : 124 - 128
  • [8] Transapical Beating Heart Mitral Valve Repair
    Seeburger, Joerg
    Borger, Michael Andrew
    Tschernich, Heinz
    Leontjev, Sergej
    Holzhey, David
    Noack, Thilo
    Ender, Joerg
    Mohr, Friedrich Wilhelm
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (06) : 611 - 612
  • [9] Artificial papillary muscle device for off-pump transapical mitral valve repair
    Imbrie-Moore, Annabel M.
    Zhu, Yuanjia
    Park, Matthew H.
    Paulsen, Michael J.
    Wang, Hanjay
    Woo, Y. Joseph
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 164 (04): : E133 - E141
  • [10] Numerical simulation of transapical off-pump mitral valve repair with neochordae implantation
    Gaidulis, Gediminas
    Votta, Emiliano
    Selmi, Matteo
    Aidietiene, Sigita
    Aidietis, Audrius
    Kacianauskas, Rimantas