The effect of coronal preflaring on the accuracy of two electronic apex locators

被引:2
|
作者
Suryantoro, R. [1 ]
Meidyawati, R. [1 ]
Suprastiwi, E. [1 ]
机构
[1] Univ Indonesia, Dept Conservat Dent, Fac Dent, Jakarta, Indonesia
关键词
IN-VIVO EVALUATION; ROOT ZX; LENGTH; FREQUENCY;
D O I
10.1088/1742-6596/884/1/012059
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
One of the main factors that determines the success of root canal treatment is the instrumentation confined to the root canal; specific methods are available for measuring its working length. This study aims to compare the accuracy of two types of apex locators and evaluate the influence of coronal preflaring on their use. The working lengths of sixteen first mandibular bicuspids were measured visually, using two types of apex locators before and after coronal preflaring. The result showed that there is a statistically significant difference between the two types of apex locators before coronal preflaring, but no statistically significant difference after coronal preflaring. The study concludes that coronal preflaring increases the accuracy of apex locators in locating the apical foramen.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study
    Jain, Saru
    Kapur, Ravi
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (06) : 140 - 145
  • [22] Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study
    Tosun, G.
    Erdemir, A.
    Eldeniz, A. U.
    Sermet, U.
    Sener, Y.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (05) : 436 - 441
  • [23] Comparative Evaluation of Accuracy of Two Electronic Apex Locators in the Presence of Contemporary Irrigants: An In vitro Study
    Baruah, Queentaj
    Sinha, Nidhi
    Singh, Bijay
    Reddy, P. Narendranatha
    Baruah, Kaveri
    Augustine, Vaishak
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2018, 8 (04): : 349 - 353
  • [24] Effect of electronic apex locators on cardiac pacemaker function
    Garofalo, RR
    Ede, EN
    Dorn, SO
    Kuttler, S
    JOURNAL OF ENDODONTICS, 2002, 28 (12) : 831 - 833
  • [25] Evaluation of the accuracy of three electronic apex locators using glass tubules
    Fan, W
    Fan, B
    Gutmann, JL
    Bian, Z
    Fan, MW
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (02) : 127 - 135
  • [27] Accuracy of electronic apex locators in primary teeth: a meta-analysis
    Ahmad, I. A.
    Pani, S. C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (03) : 298 - 307
  • [28] Evaluation of the Accuracy of Electronic Apex Locators in Modern Endodontics: An Umbrella Review
    Pisano, Massimo
    Sangiovanni, Giuseppe
    Frucci, Eugenio
    Scorziello, Michela
    De Benedetto, Giuseppina
    Iandolo, Alfredo
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [29] In vitro evaluation of the accuracy of Root ZX series electronic apex locators
    Duh, Bor-Ren
    JOURNAL OF DENTAL SCIENCES, 2009, 4 (02) : 75 - 80
  • [30] Accuracy of electronic apex locators in comparison to actual length - an in vivo study
    Haffner, C
    Folwaczny, M
    Galler, K
    Hickel, R
    JOURNAL OF DENTISTRY, 2005, 33 (08) : 619 - 625