Effect of electronic apex locators on cardiac pacemaker function

被引:26
|
作者
Garofalo, RR [1 ]
Ede, EN [1 ]
Dorn, SO [1 ]
Kuttler, S [1 ]
机构
[1] Nova SE Univ, Coll Dent Med, Dept Endodont, Ft Lauderdale, FL 33316 USA
关键词
D O I
10.1097/00004770-200212000-00009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to assess the effects of five electronic apex locators on pacemaker function in vitro. A Biotronik Actros DR+ pacemaker was evaluated at maximum sensitivity on a flat bench top. The pacemaker lead, electronic apex locator, and oscilloscope were connected across a 150-ohm resistor. Pace monitoring was carried out with a Biotronik EPR 1000 programmer and a Tektronix TDS 220 2-channel digital real-time oscilloscope. Four of five electronic apex locators tested did not cause inhibition or interfere with normal pacemaker function. It seems that electronic apex locators can be used safely in patients with pacemakers.
引用
收藏
页码:831 / 833
页数:3
相关论文
共 50 条
  • [2] The effects of six electronic apex locators on pacemaker function: an in vitro study
    Gomez, G.
    Duran-Sindreu, F.
    Jara Clemente, F.
    Garofalo, R. R.
    Garcia, M.
    Bueno, R.
    Roig, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (05) : 399 - 405
  • [3] Electronic apex locators
    Gordon, MPJ
    Chandler, NP
    INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) : 425 - 437
  • [4] The effect of coronal preflaring on the accuracy of two electronic apex locators
    Suryantoro, R.
    Meidyawati, R.
    Suprastiwi, E.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [5] Use of electronic apex locators may improve determination of working lengthQuestion: Are electronic apex locators (EALs) accurate?
    Isabel Mello
    Evidence-Based Dentistry, 2014, 15 (4) : 120 - 120
  • [6] Occurrence of no-function of two electronic apex locators: an in vivo study
    Chevalier, Valerie
    Arbab-Chirani, Reza
    Nicolas, Marie
    Morin, Vincent
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (06): : E61 - E65
  • [7] Use of an electronic apex locator on a cardiac pacemaker patient
    Beach, CW
    Bramwell, JD
    Hutter, JW
    JOURNAL OF ENDODONTICS, 1996, 22 (04) : 182 - 184
  • [8] Effect of using electronic apex locators on selected endodontic treatment parameters
    Fouad, AF
    Reid, LC
    JOURNAL OF ENDODONTICS, 2000, 26 (06) : 364 - 367
  • [9] An overview of electronic apex locators: part 1
    Ali, R.
    Okechukwu, N. C.
    Brunton, P.
    Nattress, B.
    BRITISH DENTAL JOURNAL, 2013, 214 (04) : 155 - 158
  • [10] THE USE OF ELECTRONIC APEX LOCATORS IN ENDODONTIC THERAPY
    FOUAD, AF