The effect of coronal preflaring on the accuracy of two electronic apex locators

被引:2
|
作者
Suryantoro, R. [1 ]
Meidyawati, R. [1 ]
Suprastiwi, E. [1 ]
机构
[1] Univ Indonesia, Dept Conservat Dent, Fac Dent, Jakarta, Indonesia
关键词
IN-VIVO EVALUATION; ROOT ZX; LENGTH; FREQUENCY;
D O I
10.1088/1742-6596/884/1/012059
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
One of the main factors that determines the success of root canal treatment is the instrumentation confined to the root canal; specific methods are available for measuring its working length. This study aims to compare the accuracy of two types of apex locators and evaluate the influence of coronal preflaring on their use. The working lengths of sixteen first mandibular bicuspids were measured visually, using two types of apex locators before and after coronal preflaring. The result showed that there is a statistically significant difference between the two types of apex locators before coronal preflaring, but no statistically significant difference after coronal preflaring. The study concludes that coronal preflaring increases the accuracy of apex locators in locating the apical foramen.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Coronal preflaring's influence on the accuracy of root canal length determination by electronic apex locators
    Batista, Larissa C. Novaes
    Janini, Ana Cristina Padilha
    Marciano, Marina A.
    Guimaraes, Tatiany G. F. Araujo
    Guimaraes, Bruno Martini
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2024, 65 (03): : 115 - 120
  • [2] Influence of Preflaring on the Accuracy of Length Determination With Four Electronic Apex Locators
    de Camargo, Ericson Janolio
    Zapata, Ronald Ordinola
    Medeiros, Paulo Leal
    Bramante, Clovis Monteiro
    Bernardineli, Norberti
    Garcia, Roberto Brandao
    de Moraes, Ivaldo Gomes
    Hungaro Duarte, Marco Antonio
    JOURNAL OF ENDODONTICS, 2009, 35 (09) : 1300 - 1302
  • [3] Effect of preflaring on Root ZX apex locators
    Ibarrola, JL
    Chapman, BL
    Howard, JH
    Knowles, KI
    Ludlow, MO
    JOURNAL OF ENDODONTICS, 1999, 25 (09) : 625 - 626
  • [4] Accuracy of two electronic apex locators in primary teeth
    Bolan, Michele
    de Carvalho Rocha, Maria Jose
    ENDO-ENDODONTIC PRACTICE TODAY, 2010, 4 (01): : 49 - 54
  • [5] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72
  • [6] Effect of pre-flaring and file size on the accuracy of two electronic apex locators
    Brito-Junior, Manoel
    Camilo, Carla Cristina
    Moreira-Junior, Gil
    Pecora, Jesus Djalma
    Sousa-Neto, Manoel Damiao
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (05) : 538 - 543
  • [7] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Marek, Ewa
    Lagocka, Ryta
    Kot, Katarzyna
    Wozniak, Krzysztof
    Lipski, Mariusz
    BMC ORAL HEALTH, 2019, 20 (01)
  • [8] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Ewa Marek
    Ryta Łagocka
    Katarzyna Kot
    Krzysztof Woźniak
    Mariusz Lipski
    BMC Oral Health, 20
  • [9] Influence of different sized files on the accuracy of two electronic apex locators
    Orosco, Fernando A.
    da Silva, Guilherme F.
    Weckwerth, Paulo H.
    Lopes, Maria Thereza M.
    Garcia, Alan M. R.
    Duarte, Marco Antonio H.
    de Moraes, Ivaldo G.
    AUSTRALIAN ENDODONTIC JOURNAL, 2018, 44 (03) : 251 - 254
  • [10] In vitro evaluation of the accuracy of three electronic apex locators
    Lucena-Martín, C
    Robles-Gijón, V
    Ferrer-Luque, M
    de Mondelo, JMNR
    JOURNAL OF ENDODONTICS, 2004, 30 (04) : 231 - 233