Microfluidic Magnetic Bead Assay for Cell Detection

被引:32
|
作者
Liu, Fan [1 ]
Pawan, K. C. [2 ]
Zhang, Ge [2 ]
Zhe, Jiang [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
[2] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
基金
美国国家科学基金会;
关键词
POLYMERASE-CHAIN-REACTION; HUMAN PERIPHERAL-BLOOD; STEM-CELLS; ENDOTHELIAL-CELLS; FLOW-CYTOMETRY; BREAST-CANCER; RARE CELLS; SEPARATION; DIFFERENTIATION; ANGIOGENESIS;
D O I
10.1021/acs.analchem.5b02716
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a novel cell detection device based on a magnetic bead cell assay and microfluidic Coulter counting technology. The device cannot only accurately measure cells size distribution and concentration but also detect specific target cells. The device consists of two identical micro Coulter counters separated by a fluid chamber where an external magnetic field is applied. Antibody-functionalized magnetic beads were bound to specific antigens expressed on the target cells. A high-gradient magnetic field was applied to the chamber closer to the second counter via an external cylindrical magnet. Because of the magnetic interaction between the magnetic beads and the magnetic field, target cells were retarded by the magnetic field; transit time of a target cell (bound with magnetic beads) passing through the second counter was longer than that through the first counter. In comparison, transit times of a nontarget cell remained nearly the same when it passed through both counters. Thus, from the transit time delay we can identify target cells and quantify their concentration in a cell suspension. The transit time and the size of each cell were accurately measured in terms of the width and amplitude of the resistive pulses generated from the two Coulter counters. Experiments demonstrated that for mixed cells with various target cell ratios, the transit time delay increased approximately linearly with the increasing target cell ratio. The limit of detection (LOD) of the assay was estimated to be 5.6% in terms of target cell ratio. Cell viability tests further demonstrated that most cells were viable after the detection. With the simple device configuration and easy sample preparation, this rapid and reliable method is expected to accurately detect target cells and could be applied to facilitate stem cell isolation and characterization.
引用
收藏
页码:711 / 717
页数:7
相关论文
共 50 条
  • [1] TARGET CELL DETECTION VIA MICROFLUIDIC MAGNETIC BEAD ASSAY
    Liu, Fan
    Pawan, K. C.
    Zhang, Ge
    Zhe, Jiang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 10, 2017,
  • [2] In situ single cell detection via microfluidic magnetic bead assay
    Liu, Fan
    Pawan, K. C.
    Zhang, Ge
    Zhe, Jiang
    PLOS ONE, 2017, 12 (02):
  • [3] Integrated microfluidic chip for cell culture and stimulation and magnetic bead-based biomarker detection
    Ruffert, Christine
    Ramadan, Qasem
    Ruegg, Matthieu
    Vergères, Guy
    Gijs, Martin A. M.
    Micro and Nanosystems, 2014, 6 (01) : 61 - 68
  • [4] Magnetic-bead-based microfluidic systems for detection of genetic diseases
    Lien, Kang Yi
    Liu, Chien-Ju
    Lee, Gwo-Bin
    MEMS 2008: 21ST IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2008, : 66 - 69
  • [5] Microfluidic magnetic bead conveyor belt
    van Pelt, Stijn
    Frijns, Arjan
    den Toonder, Jaap
    LAB ON A CHIP, 2017, 17 (22) : 3826 - 3840
  • [6] A microfluidic magnetic bead impact generator for physical stimulation of osteoblast cell
    Song, Suk-Heung
    Choi, Jeongheon
    Jung, Hyo-Ii
    ELECTROPHORESIS, 2010, 31 (16) : 2762 - 2770
  • [7] Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays
    Tekin, H. Cumhur
    Gijs, Martin A. M.
    LAB ON A CHIP, 2013, 13 (24) : 4711 - 4739
  • [8] Microfluidic, bead-based assay: Theory and experiments
    Thompson, Jason A.
    Bau, Haim H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 228 - 236
  • [9] Magnetic bead-based hybridization assay for electrochemical detection of microRNA
    Bartosik, Martin (martin.bartosik@mou.cz), 1600, Elsevier B.V., Netherlands (813):
  • [10] Magnetic bead-based hybridization assay for electrochemical detection of microRNA
    Bartosik, Martin
    Hrstka, Roman
    Palecek, Emil
    Vojtesek, Borivoj
    ANALYTICA CHIMICA ACTA, 2014, 813 : 35 - 40