Microfluidic Magnetic Bead Assay for Cell Detection

被引:32
|
作者
Liu, Fan [1 ]
Pawan, K. C. [2 ]
Zhang, Ge [2 ]
Zhe, Jiang [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
[2] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
基金
美国国家科学基金会;
关键词
POLYMERASE-CHAIN-REACTION; HUMAN PERIPHERAL-BLOOD; STEM-CELLS; ENDOTHELIAL-CELLS; FLOW-CYTOMETRY; BREAST-CANCER; RARE CELLS; SEPARATION; DIFFERENTIATION; ANGIOGENESIS;
D O I
10.1021/acs.analchem.5b02716
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a novel cell detection device based on a magnetic bead cell assay and microfluidic Coulter counting technology. The device cannot only accurately measure cells size distribution and concentration but also detect specific target cells. The device consists of two identical micro Coulter counters separated by a fluid chamber where an external magnetic field is applied. Antibody-functionalized magnetic beads were bound to specific antigens expressed on the target cells. A high-gradient magnetic field was applied to the chamber closer to the second counter via an external cylindrical magnet. Because of the magnetic interaction between the magnetic beads and the magnetic field, target cells were retarded by the magnetic field; transit time of a target cell (bound with magnetic beads) passing through the second counter was longer than that through the first counter. In comparison, transit times of a nontarget cell remained nearly the same when it passed through both counters. Thus, from the transit time delay we can identify target cells and quantify their concentration in a cell suspension. The transit time and the size of each cell were accurately measured in terms of the width and amplitude of the resistive pulses generated from the two Coulter counters. Experiments demonstrated that for mixed cells with various target cell ratios, the transit time delay increased approximately linearly with the increasing target cell ratio. The limit of detection (LOD) of the assay was estimated to be 5.6% in terms of target cell ratio. Cell viability tests further demonstrated that most cells were viable after the detection. With the simple device configuration and easy sample preparation, this rapid and reliable method is expected to accurately detect target cells and could be applied to facilitate stem cell isolation and characterization.
引用
收藏
页码:711 / 717
页数:7
相关论文
共 50 条
  • [41] Magnetic microspheres-based cytometric bead array assay for highly sensitive detection of ochratoxin A
    Kong, Weijun
    Xiao, Changbin
    Ying, Guangyao
    Liu, Xiaofei
    Zhao, Xiaohong
    Wang, Ruilin
    Wan, Li
    Yang, Meihua
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 420 - 428
  • [42] Fabrication of microfluidic devices incorporating bead-based reaction and microarray-based detection system for enzymatic assay
    Kim, Dae Nyun
    Lee, Yeol
    Koh, Won-Gun
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) : 305 - 312
  • [43] Microfluidic bead trap as a visual bar for quantitative detection of oligonucleotides
    Zhao, Zichen
    Bao, Yuanye
    Chu, Lok Ting
    Ho, John Kin Lim
    Chieng, Ching-Chang
    Chen, Ting-Hsuan
    LAB ON A CHIP, 2017, 17 (19) : 3240 - 3245
  • [44] Porous bead-based microfluidic assay: theory and confocal microscope imaging
    Thompson, Jason A.
    Bau, Haim H.
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 12 (1-4) : 625 - 637
  • [45] A Microfluidic Microbeads Fluorescence Assay with Quantum Dots-Bead-DNA Probe
    Ankireddy, S. R.
    Kim, Jongsung
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (03) : 2897 - 2899
  • [46] Rotation-Driven Microfluidic Disc for White Blood Cell Enumeration Using Magnetic Bead Aggregation
    Ouyang, Yiwen
    Li, Jingyi
    Haverstick, Doris M.
    Landers, James P.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 11046 - 11054
  • [47] Porous bead-based microfluidic assay: theory and confocal microscope imaging
    Jason A. Thompson
    Haim H. Bau
    Microfluidics and Nanofluidics, 2012, 12 : 625 - 637
  • [48] A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification
    Wang, Chih-Hung
    Lien, Kang-Yi
    Wu, Jiunn-Jong
    Lee, Gwo-Bin
    LAB ON A CHIP, 2011, 11 (08) : 1521 - 1531
  • [49] Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay
    Schilling, EA
    Kamholz, AE
    Yager, P
    ANALYTICAL CHEMISTRY, 2002, 74 (08) : 1798 - 1804
  • [50] Small volume bead assay for ovalbumin with electrochemical detection
    Purushothama, S
    Kradtap, S
    Wijayawardhana, CA
    Halsall, HB
    Heineman, WR
    ANALYST, 2001, 126 (03) : 337 - 341