Microfluidic Magnetic Bead Assay for Cell Detection

被引:32
|
作者
Liu, Fan [1 ]
Pawan, K. C. [2 ]
Zhang, Ge [2 ]
Zhe, Jiang [1 ]
机构
[1] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
[2] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
基金
美国国家科学基金会;
关键词
POLYMERASE-CHAIN-REACTION; HUMAN PERIPHERAL-BLOOD; STEM-CELLS; ENDOTHELIAL-CELLS; FLOW-CYTOMETRY; BREAST-CANCER; RARE CELLS; SEPARATION; DIFFERENTIATION; ANGIOGENESIS;
D O I
10.1021/acs.analchem.5b02716
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a novel cell detection device based on a magnetic bead cell assay and microfluidic Coulter counting technology. The device cannot only accurately measure cells size distribution and concentration but also detect specific target cells. The device consists of two identical micro Coulter counters separated by a fluid chamber where an external magnetic field is applied. Antibody-functionalized magnetic beads were bound to specific antigens expressed on the target cells. A high-gradient magnetic field was applied to the chamber closer to the second counter via an external cylindrical magnet. Because of the magnetic interaction between the magnetic beads and the magnetic field, target cells were retarded by the magnetic field; transit time of a target cell (bound with magnetic beads) passing through the second counter was longer than that through the first counter. In comparison, transit times of a nontarget cell remained nearly the same when it passed through both counters. Thus, from the transit time delay we can identify target cells and quantify their concentration in a cell suspension. The transit time and the size of each cell were accurately measured in terms of the width and amplitude of the resistive pulses generated from the two Coulter counters. Experiments demonstrated that for mixed cells with various target cell ratios, the transit time delay increased approximately linearly with the increasing target cell ratio. The limit of detection (LOD) of the assay was estimated to be 5.6% in terms of target cell ratio. Cell viability tests further demonstrated that most cells were viable after the detection. With the simple device configuration and easy sample preparation, this rapid and reliable method is expected to accurately detect target cells and could be applied to facilitate stem cell isolation and characterization.
引用
收藏
页码:711 / 717
页数:7
相关论文
共 50 条
  • [31] Magnetic bead-based DNA hybridization assay with chemiluminescence and chemiluminescent imaging detection
    Li, Haigang
    He, Zhike
    ANALYST, 2009, 134 (04) : 800 - 804
  • [32] Magnetic bead-quantum dot assay for detection of a biomarker for traumatic brain injury
    Kim, Chloe
    Searson, Peter C.
    NANOSCALE, 2015, 7 (42) : 17820 - 17826
  • [33] Microfluidic devices integrated with permalloy micropatterns for bead-based assay
    Ichikawa, N
    Katsuyama, Y
    Nagasaki, Y
    Ichiki, T
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 384 - 386
  • [34] An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    LAB ON A CHIP, 2002, 2 (01) : 27 - 30
  • [35] Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    Sasso, Lawrence A.
    Johnston, Ian H.
    Zheng, Mingde
    Gupte, Rohit K.
    Uendar, Akif
    Zahn, Jeffrey D.
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (04) : 603 - 612
  • [36] Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    Lawrence A. Sasso
    Ian H. Johnston
    Mingde Zheng
    Rohit K. Gupte
    Akif Ündar
    Jeffrey D. Zahn
    Microfluidics and Nanofluidics, 2012, 13 : 603 - 612
  • [37] Digital microfluidic assay for protein detection
    Mok, Janine
    Mindrinos, Michael N.
    Davis, Ronald W.
    Javanmard, Mehdi
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (06) : 2110 - 2115
  • [38] Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay
    Xu, Ting
    Zhang, Qiang
    Fan, Ya-han
    Li, Ru-qing
    Lu, Hua
    Zhao, Shu-ming
    Jiang, Tian-lun
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 3347 - 3356
  • [39] MICROFLUIDIC MAGNETIC CELL SORTING SYSTEM FOR CTC DETECTION AND TYPING
    Saliba, A. -E.
    Saias, L.
    Salamero, J.
    Fraisier, V.
    Pierga, J. -Y.
    Bidard, F. C.
    Mathiot, C.
    Vielh, P.
    Farace, F.
    Viovy, J. -L.
    ANTICANCER RESEARCH, 2008, 28 (5C) : 3530 - 3531
  • [40] A novel and rapid assay for HIV-1 protease detection using magnetic bead mediation
    Esseghaier, Chiheb
    Ng, Andy
    Zourob, Mohammed
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 335 - 341