TARGET CELL DETECTION VIA MICROFLUIDIC MAGNETIC BEAD ASSAY

被引:0
|
作者
Liu, Fan [1 ]
Pawan, K. C. [1 ]
Zhang, Ge [1 ]
Zhe, Jiang [1 ]
机构
[1] Univ Akron, Akron, OH 44325 USA
基金
美国国家科学基金会;
关键词
POLYMERASE-CHAIN-REACTION; DIFFERENTIATION; WATER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We present a novel cell detection device based on a magnetic bead cell assay and microfluidic Coulter counting technology. The device can detect specific target cells ratios, as well as cells size distribution and concentrations. The device consists of two identical micro Coulter counters separated by a fluid chamber where an external magnetic field is applied. Target cells conjugated with magnetic beads are retarded by the magnetic field; transit time of a target cell passing through the second counter is longer than that through the first counter. In comparison, a non target cell transit through two counters with nearly the same time. We demonstrated the transit time delay increased approximately linearly with the increasing target cell concentration. The limit of detection (LOD) of the assay was estimated to be 5.6% in terms of target cell ratio.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Microfluidic Magnetic Bead Assay for Cell Detection
    Liu, Fan
    Pawan, K. C.
    Zhang, Ge
    Zhe, Jiang
    ANALYTICAL CHEMISTRY, 2016, 88 (01) : 711 - 717
  • [2] In situ single cell detection via microfluidic magnetic bead assay
    Liu, Fan
    Pawan, K. C.
    Zhang, Ge
    Zhe, Jiang
    PLOS ONE, 2017, 12 (02):
  • [3] Integrated microfluidic chip for cell culture and stimulation and magnetic bead-based biomarker detection
    Ruffert, Christine
    Ramadan, Qasem
    Ruegg, Matthieu
    Vergères, Guy
    Gijs, Martin A. M.
    Micro and Nanosystems, 2014, 6 (01) : 61 - 68
  • [4] Magnetic-bead-based microfluidic systems for detection of genetic diseases
    Lien, Kang Yi
    Liu, Chien-Ju
    Lee, Gwo-Bin
    MEMS 2008: 21ST IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2008, : 66 - 69
  • [5] Microfluidic magnetic bead conveyor belt
    van Pelt, Stijn
    Frijns, Arjan
    den Toonder, Jaap
    LAB ON A CHIP, 2017, 17 (22) : 3826 - 3840
  • [6] A microfluidic magnetic bead impact generator for physical stimulation of osteoblast cell
    Song, Suk-Heung
    Choi, Jeongheon
    Jung, Hyo-Ii
    ELECTROPHORESIS, 2010, 31 (16) : 2762 - 2770
  • [7] Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays
    Tekin, H. Cumhur
    Gijs, Martin A. M.
    LAB ON A CHIP, 2013, 13 (24) : 4711 - 4739
  • [8] Microfluidic, bead-based assay: Theory and experiments
    Thompson, Jason A.
    Bau, Haim H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 228 - 236
  • [9] Magnetic bead-based hybridization assay for electrochemical detection of microRNA
    Bartosik, Martin (martin.bartosik@mou.cz), 1600, Elsevier B.V., Netherlands (813):
  • [10] Magnetic bead-based hybridization assay for electrochemical detection of microRNA
    Bartosik, Martin
    Hrstka, Roman
    Palecek, Emil
    Vojtesek, Borivoj
    ANALYTICA CHIMICA ACTA, 2014, 813 : 35 - 40