Functional slit lamp biomicroscopy for imaging bulbar conjunctival microvasculature in contact lens wearers

被引:52
|
作者
Jiang, Hong [1 ,2 ]
Zhong, Jianguang [1 ,3 ]
DeBuc, Delia Cabrera [1 ]
Tao, Aizhu [1 ,4 ]
Xu, Zhe [1 ,4 ]
Lam, Byron L. [1 ]
Liu, Che [1 ,5 ]
Wang, Jianhua [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Dept Neurol, Miami, FL 33136 USA
[3] Hangzhou First Peoples Hosp, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[5] Univ Miami, Dept Biomed Engn, Miami, FL 33136 USA
关键词
ASSISTED INTRAVITAL MICROSCOPY; SHEAR-STRESS QUANTIFICATION; BLOOD-CELL VELOCITY; FRACTAL ANALYSIS; RESOLUTION; MICROANGIOPATHY; ABNORMALITIES; CAPILLARIES; METHODOLOGY; RETINOPATHY;
D O I
10.1016/j.mvr.2014.01.005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To develop, test and validate functional slit lamp biomicroscopy (FSLB) for generating non-invasive bulbar conjunctival microvascular perfusion maps (nMPMs) and assessing morphometry and hemodynamics. Methods: FSLB was adapted from a traditional slit-lamp microscope by attaching a digital camera to image the bulbar conjunctiva to create nMPMs and measure venular blood flow hemodynamics. High definition images with a large field of view were obtained on the temporal bulbar conjunctiva for creating nMPMs. A high imaging rate of 60 frames per second and an similar to 210x high magnification were achieved using the camera inherited high speed setting and Movie Crop Function, for imaging hemodynamics. Custom software was developed to segment bulbar conjunctival nMPMs for further fractal analysis and quantitatively measure blood vessel diameter, blood flow velocity and flow rate. Six human subjects were imaged before and after 6 h of wearing contact lenses. Monofractal and multifractal analyses were performed to quantify fractality of the nMPMs. Results: The mean bulbar conjunctival vessel diameter was 18.8 +/- 2.7 mu m at baseline and increased to 19.6 +/- 2.4 mu m after 6 h of lens wear (P = 0.020). The blood flow velocity was increased from 0.60 +/- 0.12 mm/s to 0.88 +/- 0.21 mm/s (P = 0.001). The blood flow rate was also increased from 129.8 +/- 59.9 pl/s to 207.2 +/- 81.3 pl/s (P = 0.001). Bulbar conjunctival nMPMs showed the intricate details of the bulbar conjunctival microvascular network. At baseline, fractal dimension was 1.63 +/- 0.05 and 1.71 +/- 0.03 analyzed by monofractal and multifractal analyses, respectively. Significant increases in fractal dimensions were found after 6 h of lens wear (P < 0.05). Conclusions: Microvascular network's fractality, morphometry and hemodynamics of the human bulbar conjunctiva can be measured easily and reliably using FSLB. The alternations of the fractal dimensions, morphometry and hemodynamics during contact lens wear may indicate ocular microvascular responses to contact lens wear. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [31] PATIENT FACTORS INFLUENCING CONJUNCTIVAL STAINING WITH SOFT CONTACT-LENS WEARERS
    ROBBOY, M
    COX, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 738 - 738
  • [32] Morphological changes of the conjunctival epithelium in contact lens wearers evaluated by impression cytology
    Aragona, P
    Ferreri, G
    Micali, A
    Puzzolo, D
    EYE, 1998, 12 (3) : 461 - 466
  • [33] Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers
    Chen, Qi
    Jiang, Hong
    Wang, Jianhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 99 - 109
  • [34] In vivo oximetry of human bulbar conjunctival and episcleral microvasculature using snapshot multispectral imaging
    MacKenzie, L. E.
    Choudhary, T. R.
    McNaught, A. I.
    Harvey, A. R.
    EXPERIMENTAL EYE RESEARCH, 2016, 149 : 48 - 58
  • [35] THE X16 SLIT-LAMP EYEPIECE, A HIGH PLUS LENS FOR INDIRECT BIOMICROSCOPY
    BARTOV, E
    MOISSEIEV, J
    BLUMENTHAL, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 101 (05) : 620 - 621
  • [36] Changes in bulbar conjunctival microcirculation and microvasculature during short-term scleral lens wearing and their associated factors
    Fan, Xin
    Huang, Huimin
    Shi, Ce
    Jiang, Jun
    Lu, Fan
    Shen, Meixiao
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (05):
  • [37] Functional visual acuity in rigid gas permeable contact lens wearers
    Suzuki, Takashi
    Itokawa, Takashi
    Koh, Shizuka
    Hori, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [38] A CORNEAL CONTACT PRISM AND A CORNEAL CONTACT LENS FOR SLIT LAMP BIOMICROSCOPIC EXAMINATION OF THE PERIPHERAL AND CENTRAL FUNDUS
    BRALEY, AE
    ALLEN, L
    TRANSACTIONS OF THE AMERICAN OPHTHALMOLOGICAL SOCIETY, 1951, 49 : 477 - 483
  • [39] Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
    Urrets-Zavalia, J
    Urrets-Zavalia, E
    Iros, M
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2000, 23 (04): : 361 - 363
  • [40] SLIT-LAMP FUNDUS MICROSCOPY WITHOUT CONTACT-LENS AND WITH LASER ATTACHMENT
    SCHIRMER, KE
    ARCHIVES OF OPHTHALMOLOGY, 1981, 99 (01) : 155 - 157